IDS 816 700-283-02I Issued September 2009
13
Use only a spring-loaded momentary key-switch or non-latching remote control unit.
2.8 IDS Remote Receiver
An IDS Remote Receiver (P/N 860-07-002DI) may be connected to the keypad bus. Using this facility
allows remote arming and disarming of the panel while providing user identification for a maximum of 32
remotes.
2.9 Radio Transmitter Connection
When connecting a radio transmitter, use the TX terminal provided on the PCB to supply power to the
transmitter. (Figure 1) The 4 Amp battery fuse protects this output.
3. Hardware Reset Switch
Should the need arise to return the panel to factory default, use the hardware reset switch (Figure 1).
The panel may be defaulted as follows:
Remove both battery and AC power from the panel. While depressing the reset switch reapply power to
the panel by either connecting the battery or the AC power. Release the reset switch approximately 2
seconds after reapplying the power. Factory default values will now be restored to all locations and all
attached keypad IDs will be defaulted. A default event will be logged and the existing event log will NOT
be erased.
NOTE:
If reset switch has been disabled by programming a 10 into location 444, it will no longer be possible to
default the panel using the reset switch. The panel can only be defaulted if a valid installer code is
entered and a value of [0] is entered into location 0.
4. Enrolling Keypads and Other Devices
A new panel supplied from the factory will have factory default values in all locations (as indicated
throughout this manual). Similarly new keypads will have no ID assigned to them. It is however good
practice to default the system by using the reset switch prior to commencement of programming. This will
ensure that the above is true and that no factory test values remain.
The keypad(s) attached to a system as defaulted above will have no ID and will therefore not
communicate with the panel. This is indicated by all keypad LED’s flashing simultaneously.
In order to enrol a keypad (thereby giving the keypad an ID) press the
[#]
key of the keypad
you wish to enrol. The enrolled keypad will now indicate the alarm status. Repeat this process with the
remaining keypads where more than 1 keypad is used.
The first keypad enrolled will have an ID of 1, the second enrolled will have an ID of 2, the third an ID of 3
etc. A maximum of 8 keypads may be used.
(The
[P]
and
[M]
keys can be used to scroll up and down trough the menu functions).
NOTE:
If the keypad zone is to be used, consideration must be given to the sequence in which keypads are
enrolled as this affects the LED zone designation. The keypad 1 will contain zone 16, keypad 2 will
contain zone 15 etc. as per section 14 in this manual.
Summary of Contents for 816
Page 1: ......
Page 2: ...IDS 816 700 283 02I Issued September 2009 2...