background image

 English 

 

28 

 

The upper signed company also declares under its own responsibility that the ASTRA STEAMER series 

referred to this declaration is in conformity with the essential safety and health protection requirements 

and also complies with the requirements concerning the following 

 regulations:. 

 

97/23/CE

 -  

Pressure Equipment Directive 

 

2006/42/EC – Machinery Directive

 

2006/95/EC – Low Voltage Directive

 

2004/108/EC – EMC

 

2002/95/EC – RoHS 

 

EN 12100-1 
EN 12100-2 

EN 60335-2-79 

EN 60204-1 
EN 55014-1 
EN 55014-2 

EN 6100-3-2 

EN 61000-3-3 

 

 

 

 

Via Petrarca, 127 - 46030 Borgoforte (MN) ITALY  

Tel. +39 0376 648756 - Fax +39 0376 649140 
e-mail: 

[email protected]

 Web: 

http://www.idromatic.it

  

REA MN-223709 / C.F. / P.Iva IT 02096330200 
Cap. Soc. € 65.000,00 i.v.

 

Dichiarazione di conformità

 

Declaration of Conformity

 

 

Name and postal address of 

manufacturer: 

 
 
 

IDROMATIC  S.r.l.

 

Via F. Petrarca 127  
46030 BORGOFORTE (MN)  
ITALY

The upper signed Company declares under its sole responsibility that items of equipment specified below have been designed , 
manufactured, inspected and tested as required by the relevant provisions of the Pressure Equipment Directive 97/23/CE and in 
compliance with the A1 Module (internal manufacturing inspection and internal manufacturing checks with monitoring of the final 
assessment) released by: 

TÜV ITALIA S.R.L.

 

( 0948 )

 

Via Giosuè Carducci 

125 edificio 23 20099 

Sesto San Giovanni (MI) 

 

Certificate No.: 

 

Date: 

 

TIS-PED-BO-11-02-081524-4675

 

 
24.02.2011

 

 

Description:

   

 

 
 

ASTRA STEAMER HEAT EXCHANGER COD. 15.341 – Assembly for ASTRA STEAMER 
series steam cleaners.  

 

ASTRA STEAMER series steam generator specifications: 

Nominal working 

pressure [bar]

 

Nominal boiler 

working 

temperature  

[°C]

 

Steam flow 

[l/min]

 

Outgoing steam 

temperature 

[°C]

 

Fuel 

Burner max 

thermal power 

[kW] 

Weight [kg] 

180 

0.7 

150 

Diesel 

32 

165 

 
 

 
 
 
 

 

 
 

  

 
 

 

 

 

Machine 

S/N 

Heat 

exchanger 

S/N 

  

  

Summary of Contents for Astra Steamer Hybrid

Page 1: ...Instruction Manual Idromatic s r l via Petrarca n 127 46030 Borgoforte MN Italy p iva e cod fiscale 02096330200 email info idromatic it website www idromatic it tel 39 0376 648756 fax 39 0376 649140...

Page 2: ......

Page 3: ...eglect abuse accident improper handling or storage exposure to moisture unauthorized modifications alterations or repairs improper installation improper use of any electrical source undue physical or...

Page 4: ...PRESSURE WASHER GETTING STARTED 15 10 PRESSURE WASHER START UP REGULAR OPERATION AND SHUTTING DOWN 16 11 MAINTENANCE PLAN 16 12 STEAM MAINTENANCE DESCALING 18 13 STEAM MAINTENANCE CLEANING BOILER SEN...

Page 5: ...screws N 2 D8 washers PRESSURE WASHER STEAM 120cm lance adjustable nozzle RL26 automatic gun 10m HP R1 hose Sandblasting kit for steam sold separately 10m hose with rubber burn protection Teflon nozzl...

Page 6: ...r assistance is requested for the steamer DIESEL STEAM GENERATOR Nominal operation Pressure bar 9 Boiler Temperature C 180 Outgoing temperature C 150 Dry steam flow rate kg h 33 Wet steam flow rate kg...

Page 7: ...r controls STEAM OUTLET PRESSURE WASHER OUTLET 3 Steam pressure gauge 4 Cold water pressure gauge 5 Indicator lights High voltage connection Normal functioning ON Burner ON Water pump ON Diesel shorta...

Page 8: ...with water Pull the trigger on the steam gun to vent the boiler and eliminate any air see section 7 Continuous light REGULAR OPERATION MODE During this phase more indicator lights will light up accor...

Page 9: ...power cord or extension cables are not damaged by running over pinching dragging or similar Protect the cable from heat oil and sharp edges Do not use the Steamer if the power cord has been damaged D...

Page 10: ...as it is running Never leave the machine unattended in areas where vehicles may pass and damage the power cord and hose Do not point the stream towards electronic devices In case the machine does not...

Page 11: ...ne or any of its components freezes it is necessary to wait until it has thawed before using it If the machine is to be stored in places where temperatures can go below 0 C 32F follow the steps descri...

Page 12: ...English 10 Figure 02 Figure03 Figure 04 Figure 05 Figure 06 Figure 07 Figure 08 8 OPEN 1 3 4 2 5 7 8 9 11 10 6...

Page 13: ...Make sure the main switch 1 fig 01 is in the OFF position d SECURE THE MACHINE WITH THE BRAKE Before initiating any operation position the machine on a firm stable surface and secure the rear wheels 1...

Page 14: ...05 tightening the nut using a 19mm wrench Cover the coupling with the rubber protective cover 4 fig 05 Plug in the hose cable as shown in the picture b CONNECT THE STEAM GUN TO THE HOSE Attach the ste...

Page 15: ...open and close the trigger to vent the boiler during start up Wait until the burner indicator light has shut off before starting to operate the machine This signals that the nominal operating pressure...

Page 16: ...steam as necessary e SHUTTING DOWN AND STORAGE After finishing regular usage rotate main switch 1 fig 01 to OFF then to ON to activate stand by mode indicated by slow flashing indicator Make sure to d...

Page 17: ...w in the sandblasting lance when the machine has reached nominal operating pressure 9bar b PLACE THE SUCTION TUBE IN A RECIPIENT WITH SAND Fill a container with sand appropriate for sandblasting Inser...

Page 18: ...mpurities in the tubes and lance 10 WORKING WITH THE PRESSURE WASHER START UP OPERATION AND SHUTDOWN a IF USING ONLY THE PRESSURE WASHER Rotate the main knob 1 fig 01 to STANDBY MODE Open the PRESSURE...

Page 19: ...STORAGE If using pressure washer with the steam cleaner see section 7e Close the trigger Turn switch 1 fig 01 to OFF Disconnect the external water supply hose Drain the gun hose by leaving the trigger...

Page 20: ...50 h Check up pump oil 100 h Replace pump oil 500 h MAINTENANCE IMPORTANT SAFETY PRECAUTIONS Any maintenance cleaning operation must be done only after the following operations have been performed The...

Page 21: ...the relative steam outlet open to vent the boiler c Fill an external container with approximately 20L of SALNET FOSS descaling product cod 00 129 at 20 concentration then connect a hose with quick fit...

Page 22: ...y the boiler as described in section 12b h Screw the steam gun to the hose position the rubber protection and close the steam outlet by pressing the relative button on the main panel Replace the machi...

Page 23: ...filters that have not been serviced cleaned following the maintenance plan in section 11 Figure 09 Figure 13 The water filters are essential for the protection of the water pump It is fundamental tha...

Page 24: ...lder screw 12 fig 09 15 MAINTENANCE FOR STEAM CLEANING THE FUEL FILTER The manufacturer is not responsible for any malfunctioning caused by dirty filters that have not been serviced cleaned following...

Page 25: ...plug ASTRA STEAMER EVO After the machine has cooled down remove the protective cover by removing the placeholder screw 12 fig 09 b Disconnect the fuel hose 20 fig 15 using a M10 wrench c Remove the el...

Page 26: ...mble the parts and replace the filter 17 2 CHECKING REFILLING THE PUMP OIL a Make sure to check the oil level periodically using the oil dipstick Replace the oil SAE 20 30 or equivalent after the firs...

Page 27: ...ventually the water pump If problem persists call Assistance Overheating Wait for 1 minute before shutting down the machine so that the fan can cool down the boiler Subsequently remove the cover as de...

Page 28: ...inlet line verify the state of the suction tube Clean replace valves Water leakage from the pump head Oil leakage Electric motor doesn t start Worn gaskets Worn oil gaskets No electrical current Repl...

Page 29: ...English 27 19 WIRING DIAGRAM...

Page 30: ...s of manufacturer IDROMATIC S r l Via F Petrarca 127 46030 BORGOFORTE MN ITALY The upper signed Company declares under its sole responsibility that items of equipment specified below have been designe...

Page 31: ...accessories Warranty does not cover the following 1 Damages due to unauthorized tampering modification and or repair by third parties 2 Damages due to unsuitable use not in compliance with the user m...

Page 32: ...the 18 month period is over In case any customers are interested in purchasing a new valve please refer to your local IDROMATIC distributor Idromatic does not hold itself liable for any malfunctions...

Reviews: