![Idromatic Astra Steamer Hybrid Instruction Manual Download Page 26](http://html1.mh-extra.com/html/idromatic/astra-steamer-hybrid/astra-steamer-hybrid_instruction-manual_3746216026.webp)
English
24
1
2
g.
Using a gauge, verify the gap between the nozzle and the edges of the electrodes. If necessary, adjust
using pliers.
h.
Replace the combustion head; make sure to fix the 3 screws using a star point screwdriver.
Replace the fuel hose and secure the nut tightly.
Replace the photovoltaic cell.
Replace the electrode connectors.
i.
Replace the protective cover and replace the placeholder screw 12 (fig.09).
17.
MAINTENANCE FOR PRESSURE WASHER
17.1
CLEANING THE PUMP FILTER (Y FILTER):
a.
Unscrew the brass Y filter. Remove the mesh component and clean it using a pressurized air cleaner.
b.
Reassemble the parts and replace the filter.
17.2
CHECKING/REFILLING THE PUMP OIL:
a.
Make sure to check the oil level periodically using the oil dipstick. Replace the
oil (SAE 20/30 or equivalent) after the first 100 h of work
and afterwards, every 500 h.
b.
Unscrew the discharge (pos 1) and fill plug (pos
2) and drain the oil inside (make sure to
properly dispose of the old oil)
c.
Screw the discharge plug (pos 1) back in and fill
with new oil until the optimum level is reached
(as indicated on the pump).
IF THE OIL HAS A MILKY ASPECT (WATER) PLEASE CONTACT AN AUTHORIZED DEALER FOR ASSISTANCE.
17.3
FREEZE PROTECTION:
a.
Do not leave the pump exposed to extremely low temperatures. If the machine is at risk of being exposed
to sub zero temperatures make sure to drain all water from the components before storage.
Summary of Contents for Astra Steamer Hybrid
Page 2: ......
Page 29: ...English 27 19 WIRING DIAGRAM...