Installation instructions Terra CL
15
1
2
3
4
5
6
7
8
9
10
11
12
13
1
2
3
4
5
a
b
d
c
e
e
f
g
a
b
d
c
e
e
f
g
Interior installation
In
te
rio
r ins
tall
a
tio
n
Based on accessibility, the exhaust air
opening should ideally be on the right-
hand side.
Specifi ed dimensions include clearances. Wall opening should be thicker around the wall
insulation. Minimum thickness of the wall insulation is 50 mm.
5.8.2. Customer preparation
Exhaust air opening to right
Exhaust air opening to left
An even, solid installation surface must be selected.
After positioning the heat pump, it must then be lev-
elled. There are adjustable feet on the heat pump for
this purpose.
Type
a
b
c
d
e
f
g
8
1000
830
650
830
90
650
650
10
1000
830
650
830
90
650
650
12
1100
930
680
930
90
650
650
15
1100
930
680
930
90
650
650
20
1100
930
780
930
90
750
750
25
1200
1130
880
1130
90
750
750
30
1200
1130
880
1130
90
750
750
33
1200
1130
880
1130
90
750
750
TERRA CL 08-33
All dimensions in mm
Corner installation