SWC-2000 User
’s Guide
86
9.13.3 Operation mode of LAN communication
Sets the operation mode of LAN communication.
Select “RECEIVER” or “TRANSMITTER” for “FUNCTION”.
-
“RECEIVER”: The SWC-2000 is controlled externally.
-
“TRANSMITTER”: The SWC-2000 controls external devices. Set the information of external device as
shown below.
Connection is divided into the two purpose depending on the set port number: for communication commands
and for WEB browser control.
When you finish setting, click the “SEND” button.
[Table 9.14] LAN communication setting
Setting item
Operation mode
RECEIVER
TRANSMITTER
[FUNCTION]
Operation mode
RECEIVER [Default]
TRANSMITTER
[TRANSMITTER IP]
Destination IP address
N/A
0.0.0.0 to 255.255.255.255
[Default] 192.168.1.199
[PJLink]
PJLink protocol connection
N/A
ON: Use
OFF: Not use [Default]
[TRANSMITTER PORT]
Destination port number
*1
N/A
1 to 65535 [Default] 1100
[PASSWORD]
PJLink
protocol’s
password
*2
N/A
ASCII codes 20,30 to 39,
41 to 5A, 61 to 7A in hex
[Default] 20 (space)
*
1
:
If “PJLink” is set to “ON”, the port number is “4352” fixed.
*
2
: UP to 32 characters. You do not need to set a password if you do not want to use password
ahthentication.
[Table 9.15] TCP port number
Port
Setting value
Communication port for
control commands
23,1100,6000 to 6999
Communication port for WEB
browser
80,5000 to 5999
[Default] Connections1 to 3: 1100, Connections4 to 6: 23, Connection7: 80
Tip:
The SWC-2000 has a communication port only for WEB browser. You do not need to set connection if using
only one PC.