background image

SWC-2000 User

’s Guide 

70 

If you set “MODE” to ”IDK”, the “PRODUCT” list is displayed.   
1. 

Select the desired “PRODUCT” to display reply commands for each product on the “COMMAND” list. 

 

 

[Figure 9.27] CHANNEL SELECT (V+A) template 

 

2. 

Select the desired control co

mmand and click the “OK” button to apply it to 

9.7 REPLY COMMAND 

menu (Reply command list)

”.

 

 

3. 

The control command is entered on the field below mentioned in red.   

 

4. 

Since you can set the “DATA” and “MASK” items from this template, you need to edit “MEMO” and 
“PROCESS” as needed. 

 

 

Summary of Contents for SWC-2000

Page 1: ...2000 User s Guide Ver 1 1 1 Thank you for choosing this IDK product To ensure the best performance of this product please read this User s Guide fully and carefully before using it and keep this manu...

Page 2: ...cript is a trademark or registered trademark of Oracle Corporation its subsidiaries and affiliated companies in the United States and other countries Oracle and Java are trademarks of Oracle Corporati...

Page 3: ...sts of the following two volumes User s guide this document Provides explanations and procedures for operations installation connections among devices I O adjustment and settings Command guide Please...

Page 4: ...nterference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the...

Page 5: ...if the warning is ignored or the product is handled incorrectly Indicates the presence of a hazard that may cause minor personal injury or property damage if the caution is ignored or the product is h...

Page 6: ...ss to the plug enables unplugging the product in case of any extraordinary failure abnormal situation or for easy disconnection during extended periods of non use Insert the power plug into an appropr...

Page 7: ...Do not block the vent holes If ventilation slots are blocked it may cause the product to overheat affecting performance and reliability and may increase the risk of fire Do not place or stack heavy ob...

Page 8: ...3 7 5 Initializing 24 7 6 Control status LEDs 24 7 7 Executing control commands 25 7 8 Key lock 26 8 How to use SWC 2000 27 8 1 Application example 27 8 1 1 Preparation for LAN connection 27 8 1 2 Set...

Page 9: ...8 1 WEB menu links 64 9 8 2 Setting reply command 64 9 8 3 TEMPLATE button 67 9 8 4 RELOAD button 71 9 8 5 BACK button 71 9 8 6 SEND button 71 9 9 COMMAND LINK menu Selecting button 72 9 9 1 WEB menu...

Page 10: ...13 6 SEND button 87 9 14 BACKUP RESTORE menu 88 9 14 1 WEB menu links 89 9 14 2 BACKUP 89 9 14 3 RESTORE 89 9 15 OTHERS 90 9 15 1 WEB menu links 91 9 15 2 POWER ON SETTING STANDBY BUTTON 91 9 15 3 KEY...

Page 11: ...User s Guide 11 1 Included Items Ensure that all items below are included in the package If any items are missing or damaged please contact IDK SWC 2000 1 AC adapter with screw lock 1 Figure 1 1 Inclu...

Page 12: ...SWC 2000 as optional extra By using this kit you can mount one or two SWC 2000s to an EIA rack Figure 2 1 RM SWC2001 Figure 2 2 RM SWC2002 The actual color of kits is black Table 2 1 Part number of r...

Page 13: ...llowing items are included Table 2 2 RM SWC2001 Part number Included items RM SWC2001 701A05 mounting bracket 1 701A06 mounting bracket for one SWC 2000 1 Screw Nickel plated iron M3x6 screws 4 Figure...

Page 14: ...the bracket below from the SWC 2000 s bottom Figure 2 4 Removing bracket 2 Attach the mounting brackets 701A05 and 701A06 with screws to the SWC 2000 s bottom The tightening torque is 0 59 N m 6 1 kgf...

Page 15: ...following items are included Table 2 3 RM SWC2002 Part number Included items RM SWC2002 701A04 rack mounting bracket 1 701A05 mounting bracket for double SWC 2000 2 Screw Nickel plated iron M3x6 scre...

Page 16: ...rom SWC 2000 s bottom Figure 2 7 Removing bracket 2 Attach the mounting bracket 701A04 to the two SWC 2000s bottoms with screws to connect them Attach the mounting brackets 701A05 to the two SWC 2000...

Page 17: ...ure 3 1 Remote operation using WEB browser Electric screen Versatile controller Lifting and lowering General purpose controller Contact output Video or audio signal Monitor FDX 32 SWC 2000 PC Projecto...

Page 18: ...and executes control commands Control output Controls external devices via RS 232C and LAN Outputs control command Controls matrix switchers multiple switchers and projectors Supports PJLink Other fea...

Page 19: ...green Powered on Lights in orange Powered off Standby button Powers on off the SWC 2000 Lights in green Powered on Does not light Powered off See 7 2 Powering ON OFF Control command button 1 to 16 Exe...

Page 20: ...electricity from your body Do not place the SWC 2000 on top of another one Prepare ventilating equipment to keep the ambient temperature at 40 degrees C 104 degrees F or less If inadequately vented t...

Page 21: ...SWC 2000 User s Guide 21 Attaching AC plug Gently slide the AC plug into the AC adapter until it clicks Bracket ear Figure 6 2 Attaching AC plug...

Page 22: ...WC 2000 Input signal Blu ray player Blu ray player Versatile controller Contact output HDMI monitor Electric screen 3G SDI camera DVI monitor HDMI monitor Laptop LAN External device controlled by SWC...

Page 23: ...control command Control command buttons1 to 16 KEYLOCK button See 9 10 2 TOGGLE and COMMAND Linking control command 7 3 Rebooting Control commands assigned to power on and power off operations are not...

Page 24: ...the control status LEDs COMMAND EXECUTION LED blinks in orange Control commands are being executed LED does not light No control commands are executed COMMAND ERROR LED blinks in red Timeout between...

Page 25: ...xecuted alternately by enabling the toggle operation Commands can be executed Control commands for powered ON Power button Button Control commands for powered OFF PLANE A Control command button 1 PLAN...

Page 26: ...king for all buttons All buttons Remote operations WEB browser control commands Only the KEY LOCK button is available for unlocking buttons See 9 15 4 AUTO LOCK Locking for only control command button...

Page 27: ...g a WEB browser as follows Remote switching channel Video and audio that are input from FDX 32 s IN1 are output from all outputs by pressing Control command button1 Monitor FDX 32 SWC 2000 PC HUB RS 2...

Page 28: ...values for FDX 32 as an example into the LAN1 row A Table 8 2 LAN1 setting example Item Value Description FUNCTION TRANSMITER Transmitter mode TRANSMITTER IP 192 168 1 100 FDX 32 s IP address TRANSMI...

Page 29: ...he CMD1 button D to edit control command 1 in the following advanced setting page for control command See 9 5 COMMAND EDIT menu Control command list See 9 6 COMMAND EDIT menu Advanced setting of contr...

Page 30: ...LATE button to display the following template page See 9 5 COMMAND EDIT menu Control command list G Figure 8 5 Template 10 Set the template as below in G to switch video and audio of the matrix switch...

Page 31: ...mbers are displayed in the left and right sides respectively Register the switching control command outputs video and audio that are input from FDX 32 s IN1 to all outputs After selecting IN1 and ALL...

Page 32: ...the control command that is selected in the template is entered in the DATA box J Make sure that the control command is entered Click the SEND button K to apply the setting to the SWC 2000 13 Click C...

Page 33: ...ol command button 1 Click 1 M Figure 8 8 Control command link See 9 9 COMMAND LINK menu Selecting button 15 The control command link advanced setting page is displayed Select CMD1 CH1 N N O Figure 8 9...

Page 34: ...nt to external devices by pressing the desired control command button that is linked to the control command Figure 8 10 Control command buttons 8 2 2 Control from WEB browser Procedure for controlling...

Page 35: ...Checking the list of registered reply commands NAME EDIT menu Editing control command button that is displayed in the MAIN menu e g Remote operation of control command button MAIN menu TEMPLATE Reply...

Page 36: ...C 2000 s IP address into the address bar This menu is for operating the Standby button and control command buttons Power and control commands can be executed from a WEB browser Figure 9 2 MAIN menu Co...

Page 37: ...us LED 9 2 2 Standby button Powers on and off the SWC 2000 Green Operation mode Black Standby mode 9 2 3 Control command buttons Operate the control command buttons Numbers displayed on top of control...

Page 38: ...on the WEB browser Enter the desired number of seconds 10 to 65535 into the AUTO RELOAD TIMER field 0 Does not update Default 10 to 65535 seconds Click the SET button to apply the setting 9 2 5 RELOA...

Page 39: ...can display the NAME EDIT menu by entering http SWC 2000 s IP address nameedit html into the address bar This menu is for editing the name of control command button Figure 9 3 NAME EDIT menu WEB menu...

Page 40: ...yed on the MAIN menu Type the desired name Up to 10 one byte alphabet and numbers directly into boxes 1 to 16 to change the name and click the SEND button See 9 2 MAIN menu 9 3 3 RELOAD button Reloads...

Page 41: ...ONITOR menu by entering http SWC 2000 s IP address datamonitor html into the address bar This menu is for displaying communication history of sent and received control commands Figure 9 4 DATA MONITOR...

Page 42: ...mands and received reply commands for LAN1 to LAN7 and RS 232C 9 4 3 HEX ASCII button Switches HEX ASCII Click the HEX button or ASCII button Figure 9 5 Displays in HEX or ASCII 9 4 4 STOP RUN button...

Page 43: ...SWC 2000 User s Guide 43 9 4 5 CLEAR button Deletes communication histories of sent control commands and received reply commands Click the CLEAR button...

Page 44: ...DIT menu by entering http SWC 2000 s IP address commandedit html into the address bar Click the command number button you want to edit to jump to the COMMAND EDIT menu Figure 9 7 COMMAND EDIT menu Con...

Page 45: ...control command 9 5 3 COMMAND COPY DELETE Copies and deletes registered control commands For copying Select the desired CMD numbers and click the COPY button For deleting Select the desired CMD numbe...

Page 46: ...ing of control command You can display the COMMAND EDIT menu by clicking the desired CMD button Figure 9 10 COMMAND EDIT menu Advanced setting of control command WEB menu Setting control command LINK...

Page 47: ...ticked Does not send Default Ticked Sends COMMAND SETTING DELAY Set the waiting time of the control command Use this item for devices such as projectors that requires time to cool down after powering...

Page 48: ...hex DELIMITER Checking delimiter 5 Check the DELIMITER box and specify the desired value to check the delimiter which is sent at the very last of the received data If you uncheck the box all received...

Page 49: ...set reply command 31 and 32 to CHECK Example INPUT MODE is set to ASCII Figure 9 11 Input box of control command in ASCII For special characters in ASCII use the characters in the following table Tabl...

Page 50: ...SWC 2000 User s Guide 50 Example INPUT MODE is set to HEX Figure 9 12 Input box of control command in HEX...

Page 51: ...select the desired command Figure 9 13 REPLY COMMAND LINK Check the LINK box and click the OK button to determine if the reply command is returned when the control command is sent If a reply command...

Page 52: ...and PJLink commands are originally registered You can register other commands directly See 10 Product specification See 9 6 2 Setting control command You can display buttons for inputting ASCII codes...

Page 53: ...ries e g MSD series MATRIX SWITCHER MULTI SWITCHER PRODUCT Control command for other company s sink device MANUFACTURER MODE Supported products ASCII Figure 9 15 Supported products Table 9 3 MODE MODE...

Page 54: ...COMMAND list Figure 9 16 CHANNEL SELECT V A template 2 Select the desired control command and click the OK button to apply it to 9 6 COMMAND EDIT menu Advanced setting of control command 3 The contro...

Page 55: ...SWC 2000 User s Guide 55 5 When you finish setting click the SEND button Figure 9 17 Control command has been input using input support...

Page 56: ...N P T SP CR Get input selection settings 10 1 A V M T SP 1 0 CR Switch off video mute 11 1 A V M T SP 1 1 CR Switch on video mute 12 1 A V M T SP 2 0 CR Switch off audio mute 13 1 A V M T SP 2 1 CR S...

Page 57: ...atus query command No Command Description Reply command to power status commands 1 1 P O W R 0 CR Stand by 2 1 P O W R 1 CR Power ON 3 1 P O W R 2 CR Cooling 4 1 P O W R 3 CR Warming up Reply command...

Page 58: ...alue is 0 at all times 10 Whether the lamp illuminates or not 0 or 1 0 Not illuminate 1 Illuminates For devices containing multiple lamps the accumulated time and status separated with a SP are sent 1...

Page 59: ...layed WEB menu and displays it on the WEB browser Click the RELOAD button 9 6 6 BACK button Returns to the COMMAND EDIT menu control command list Click the BACK button 9 6 7 SEND button Applies settin...

Page 60: ...SWC 2000 s IP address replycommand html into the address bar Up to 32 reply commands can be registered Click the command number button you want to edit to jump to the COMMAND EDIT menu Select the repl...

Page 61: ...iled setting page Prerequisite N A Settable range CMD button CMD 1 to CMD 32 9 7 3 REPLY COMMAND COPY DELETE Copies and deletes registered reply commands For copying Select the desired CMD numbers and...

Page 62: ...SWC 2000 User s Guide 62 9 7 4 Reload button Reloads the displayed WEB menu and displays it on the WEB browser Click the RELOAD button...

Page 63: ...ply command You can display the following page by clicking the CMD button on REPLY COMMAND menu Reply command list Figure 9 21 REPLY COMMAND menu Advanced setting of reply command WEB menu link Settin...

Page 64: ...of COMMAND consists of only 0A 0D and 20 to 7D of ASCII codes Select HEX if DATA of COMMAND includes other codes ASCII Default HEX SIZE Set the number of bytes to be received starting with the first b...

Page 65: ...ived externally not loop back Since OK and NG are registered to reply commands 31 and 32 by factory default respectively do not edit or delete those commands if you use the loop back function and chec...

Page 66: ...MODE of reply command to ASCII it is automatically set to FF For example if 0 of ASCII codes 30 in hex is replied Binary Binary Hexadecimal Received data 00110000 MASK 11111111 30 Reply command data...

Page 67: ...DK s reply commands and PJLink commands are originally registered You can register other commands directly You can display buttons for inputting ASCII codes by selecting ASCII from the MODE in order t...

Page 68: ...pported products Table 9 9 MODE MODE Description IDK Displays reply command s templates for matrix switchers and multiple switchers PJLink Displays PJLink command s template ASCII Displays buttons for...

Page 69: ...12 DC2 02 STX 13 DC3 03 ETX 14 DC4 04 EOT 15 NAK 05 ENQ 16 SYN 06 ACK 17 ETB 07 BEL 18 18 08 BS 19 EM 09 HT 1A SUB 0A LF 1B ESC 0B VT 1C FS 0C 0C 1D GS 0D CR 1E RS 0E S0 1F US 0F SI 7F DEL 10 DLE If...

Page 70: ...the COMMAND list Figure 9 27 CHANNEL SELECT V A template 2 Select the desired control command and click the OK button to apply it to 9 7 REPLY COMMAND menu Reply command list 3 The control command is...

Page 71: ...t 9 8 4 RELOAD button Reloads the displayed WEB menu and displays it on the WEB browser Click the RELOAD button 9 8 5 BACK button Returns to the REPLYCOMMAND menu Reply command list Click the BACK but...

Page 72: ...u can display the COMMAND LINK menu by entering http SWC 2000 s IP address commandlink html into the address bar This menu is for selecting the button to which registered control command is linked Fig...

Page 73: ...Executing control command 9 9 3 COMAND LINK COPY DELETE Copies and deletes linking For copying Select the desired CMD numbers and click the COPY button For deleting Select the desired CMD number and...

Page 74: ...ALID TIME The longer time either of control command execution time or the time set in this menu will be applied as the invalid operation time Only operations from ports that execute control commands w...

Page 75: ...ser s Guide 75 9 10 COMMAND LINK menu Links control commands to each execution condition Figure 9 33 COMMAND LINK menu Linking WEB menu TOGGLE and COMMAND Linking control command RELOAD BACK button SE...

Page 76: ...tion 1st 2nd 3rd 4th 5th 6th 7th 8th 9th 10th POWER OFF 1 2 3 4 5 30 31 32 Control command Execution order Linking COMMAND 1 COMMAND 3 COMMAND 4 POWER ON Figure 9 34 Linking control command Functions...

Page 77: ...played WEB menu and displays it on the WEB browser Click the RELOAD button 9 10 4 BACK button Returns to the COMMAND LINK menu Selecting button Click the BACK button 9 10 5 SEND button Applies setting...

Page 78: ...entering http SWC 2000 s IP address commandexecution html into the address bar This menu is for executing a control command that is registered to the SWC 2000 if the SWC 2000 is powered on Figure 9 35...

Page 79: ...9 11 3 COMMAND EXECUTION COMMAND ERROR indicator Shows the current control status COMMAND EXECUTION Black The SWC 2000 does not execute a control command of external devices Orange The SWC 2000 execut...

Page 80: ...u by entering http SWC 2000 s IP address led html into the address bar This menu is for setting LED s lighting and its conditions Figure 9 36 LED menu WEB menu link Blinking pattern Lighting condition...

Page 81: ...OFF Does not 1 1000sec Contunies to blink until the specified time 1 to 1000 seconds comes 9 12 3 Lighting condition Sets when and which control command buttons will light Select one of the following...

Page 82: ...executed alternately every time pressing the button Table 9 12 Toggle operation for control command button COMMAND TALLY You register a command only for one PLANE You register a command for both PLANE...

Page 83: ...SEND button Applies settings of LED menu to the SWC 2000 Click the SEND button 9 12 6 LAST BUTTON MEMORY Start up lighting by group Sets start up liting for control command buttons which are grouped...

Page 84: ...ntering http SWC 2000 s IP address lancom html into the address bar This menu is for setting LAN and RS 232C communication to connect the SWC 2000 and external devices Figure 9 38 LAN COM menu WEB men...

Page 85: ...to control the SWC 2000 externally The SWC 2000 s MAC address is also displayed but it cannot be set When you finish setting click the SEND button Table 9 13 Setting address Item Settable values Defa...

Page 86: ...TTER IP Destination IP address N A 0 0 0 0 to 255 255 255 255 Default 192 168 1 199 PJLink PJLink protocol connection N A ON Use OFF Not use Default TRANSMITTER PORT Destination port number 1 N A 1 to...

Page 87: ...hen you finish setting click the SEND button Table 9 16 RS 232C communication setting Setting item Setting value Default FUNCTION Operation mode RECEIVER TRANSMITTER RECEIVER BAUDRATE bps 4800 9600 19...

Page 88: ...he BACKUP RESTORE menu by entering http SWC 2000 s IP address backup html into the address bar This menu is for backing up the SWC 2000 s settings on the PC as a file that can be applied to other SWC...

Page 89: ...ACKUP Downloads and save the settings saved in the SWC 2000 Click the DOWNLOAD link to save the downloaded data on a PC as a backup file 9 14 3 RESTORE Applies saved setting data to the SWC 2000 Click...

Page 90: ...ERS You can display the OTHERS menu by entering http SWC 2000 s IP address others html into the address bar Figure 9 40 OTHERS menu WEB menu POWER ON SETTING STANDBY BUTTON KEY LOCK BUTTON AUTO LOCK B...

Page 91: ...FF OFF ON ON 9 15 3 KEY LOCK BUTTON Enables disables the KEYLOCK button If you select DISABLE the automatic lock of control command buttons 9 15 4 AUTO LOCK will be OFF automatically ENABLE Enables th...

Page 92: ...6 VERSION Displays the firmware version 9 15 7 RELOAD button Reloads the displayed WEB menu and displays it on the WEB browser Click the RELOAD button 9 15 8 SEND button Applies settings of OTHERS Cli...

Page 93: ...About 3 Watts Dimensions 8 46 x 3 46 x 1 59 215 W x 88 H x 40 6 D mm Projections are not included Weight 1 76 lbs 0 8 kg Temperature Operating 32 F to 104 F 0 C to 40 C Storage 4 F to 176 F 20 C to 80...

Page 94: ...link control commands in order to enable these keys 44 72 84 When a control command is executed using a control command button or external device all buttons are disabled until the command is executed...

Page 95: ...to the desired control command execution condition 76 Is the communication operation mode set to TRANSMITTER mode In order to send the control command set the communication port to TRANSMITTER mode I...

Page 96: ...1 203 204 2445 Email sales idkav com URL http www idkav com Europe IDK Europe GmbH Lise Meitner Str 6 D 40878 Ratingen TEL 49 2102 578 301 0 Email info idkav eu URL http www idkav com Product informat...

Reviews: