63
Param.
Name
Description
Range
Typical
Note
85
Motor Rated Speed
Nameplate RPM Rating
300 – 65,000 RPM
1800 RPM
86
Motor Rated Amps
Nameplate FLA Rating
0.0 – 480 Amps
Various
1
87
Motor Rated Volts
Nameplate Voltage Rating
0 – 600 Volts
230/480
VAC
88
Motor Base Frequency
Nameplate Frequency
25 – 500 Hz
50 or 60 Hz
91 Motor
Power
Factor(PF)
Nameplate Power Factor
0.4 – 0.99
Approx 0.8
2
81
Invoking this parameter begins the auto-calibration routine
Figure 11-1 Motor Parameters
NOTES:
1.
FLA = Full Load Amps
2.
The
Power Factor,
also known as Cosine Phi will sometimes be on the nameplate as
“PF”
. If the Power
Factor is given as a percentage (%), always use the decimal equivalent (for example a power factor of 84%
would be entered as 0.84) If the Power Factor is not provided by the motor manufacturer, one of the
following formulas may be used.
732
.
1
746
)
2
(
sin
cos
)
1
(
1
Current
Motor
Voltage
Motor
Efficiency
Motor
HP
Motor
r
PowerFacto
Current
Motor
Current
g
Magnetizin
r
PowerFacto
After all of the Parameters have been entered, the drive needs to perform an auto-calibration routine. This calibration
routine will take several seconds to complete. The user may use the Menu Key to back up and/or out of the
calibration any time prior to the auto calibration. The motor, and therefore the pump, will
not
run during this auto-
calibration procedure.
Summary of Contents for Pulsafeeder MPC Vector
Page 6: ......
Page 43: ...37 This page is intentionally left blank...
Page 73: ...67 Continues next page...
Page 80: ...74 16 Menu Maps...
Page 81: ...75...
Page 82: ...76...
Page 83: ...77...
Page 84: ...78...
Page 85: ...79...
Page 86: ...80...
Page 87: ...81...
Page 88: ...82...
Page 89: ...83...
Page 90: ...84...
Page 91: ...85...
Page 92: ...86...
Page 93: ...87...
Page 94: ...88...
Page 95: ...89...
Page 96: ...90...
Page 97: ...91...
Page 105: ...99 Figure 8 Handheld Remote...
Page 112: ......
Page 113: ......
Page 114: ...and Keypad Functionality BULLETIN No IOM MPCVector UMPC 11 201010 Rv A...