8
DOC No: 8540 REV E
9
DOC No: 8540 REV E
Before installing the product ensure all transit packaging has been removed.
Remove the blanks from any inlet and outlet ports. If the pump is to be stored prior to
installation, re-pack the pump in its original packing, re
fi
t the blanks to the ports and store
in a dry, covered environment.
Protect the pump head from damage during unpacking and installation. Impacts to the
magnet cup can cause internal damage or result in rub between the magnet cup and
driven magnet upon assembly with the motor.
Inspect the magnet cup before assembly with the motor. Replace or
repair if there are signs of damage.
If the pump head housing assembly and EagleDrive motor are supplied separately they
will need to be assembled prior to the installation.
Pump head should have a gasket attached to the mounting plate. If not, attach p/n
L28880-Gasket (1) to the drive side of the mounting plate. Carefully place the gasket as
concentric to the mounting plate as possible. After gasket (1) is adhered to mounting plate
(2), apply a light coating of silicone grease to the gasket. Align the pump assembly
fl
ange
(2) so that it matches with the cam locks in EagleDrive housing (3), then rotate clockwise
to lock and align with mounting screw holes. Secure using the two screws (4) supplied
with the EagleDrive. Torque screws to 0.8 N-m (7 in-lbs).
Loose bolts may result in pump/motor misalignment. Tighten bolts
appropriately. Pump/motor misalignment may result in weakening the
sealing of the enclosure. Drive housing seal described below is required
for IP55 rating.
Assembly
Unpacking and Storage
The product should be located with the inlet below or even with the liquid level of the
fl
uid
supply. The product can be mounted in any position. Ensure that there is adequate space
for operation, inspection and maintenance.
Space Requirements
Refer to the Technical Speci
fi
cation for overall dimensions and weights of the EagleDrive
and some of the most common pump/motor combinations.
Location
Pump head or adaptor cannot support the weight of the motor. Ensure
the motor is adequately supported by the foundation and/or mounting
bracket.
The foundation must be capable of supporting the combined weight of
the pump and motor and provide a rigid support.
Bulkhead Mounting (DEELE Model)
If mounting the pump/EagleDrive assembly through a bulkhead, insert the bulkhead
o-ring (1) into the groove in the face of the housing (3). Position the adaptor
fl
ange (2)
through the bulkhead hole so that it does not interfere with the sealing of the bulkhead
hole. Secure the pump/EagleDrive assembly using four screws, nuts, and washers as
needed. Tighten screws evenly and in an alternating pattern.
O-Ring 2-040 described below is necessary to ensure bulkhead is
sealed.
CAUTION