background image

8

DOC No: 8540 REV E

9

DOC No: 8540 REV E

Before installing the product ensure all transit packaging has been removed. 
Remove the blanks from any inlet and outlet ports.  If the pump is to be stored prior to 
installation, re-pack the pump in its original packing, re

fi

 t the blanks to the ports and store 

in a dry, covered environment.
Protect the pump head from damage during unpacking and installation. Impacts to the 
magnet cup can cause internal damage or result in rub between the magnet cup and 
driven magnet upon assembly with the motor.

Inspect the magnet cup before assembly with the motor.  Replace or 
repair if there are signs of damage.

If the pump head housing assembly and EagleDrive motor are supplied separately they 
will need to be assembled prior to the installation. 

Pump head should have a gasket attached to the mounting plate. If not, attach p/n 
L28880-Gasket (1) to the drive side of the mounting plate. Carefully place the gasket as 
concentric to the mounting plate as possible. After gasket (1) is adhered to mounting plate 
(2), apply a light coating of silicone grease to the gasket. Align the pump assembly 

fl

 ange 

(2) so that it matches with the cam locks in EagleDrive housing (3), then rotate clockwise 
to lock and align with mounting screw holes. Secure using the two screws (4) supplied 
with the EagleDrive. Torque screws to 0.8 N-m (7 in-lbs).

Loose bolts may result in pump/motor misalignment. Tighten bolts 
appropriately. Pump/motor misalignment may result in weakening the 
sealing of the enclosure. Drive housing seal described below is required 
for IP55 rating.

Assembly

Unpacking and Storage

The product should be located with the inlet below or even with the liquid level of the 

fl

 uid 

supply.  The product can be mounted in any position. Ensure that there is adequate space 
for operation, inspection and maintenance. 

Space Requirements

Refer to the Technical Speci

fi

 cation for overall dimensions and weights of the EagleDrive 

and some of the most common pump/motor combinations. 

Location

Pump head or adaptor cannot support the weight of the motor. Ensure 
the motor is adequately supported by the foundation and/or mounting 
bracket.

The foundation must be capable of supporting the combined weight of 
the pump and motor and provide a rigid support.

Bulkhead Mounting (DEELE Model)

If mounting the pump/EagleDrive assembly through a bulkhead, insert the bulkhead 
o-ring (1) into the groove in the face of the housing (3). Position the adaptor 

fl

 ange (2) 

through the bulkhead hole so that it does not interfere with the sealing of the bulkhead 
hole. Secure the pump/EagleDrive assembly using four screws, nuts, and washers as 
needed.  Tighten screws evenly and in an alternating pattern.

O-Ring 2-040 described below is necessary to ensure bulkhead is 
sealed.

CAUTION

Summary of Contents for MICROPUMP EagleDrive DEMSE

Page 1: ...STALLATION OPERATION AND WARRANTY INFORMATION EAGLEDRIVE TM EagleDriveTM DEMSE EagleDriveTM DEELE Without Enclosure Without Enclosure DEMSN DEELN CALL TOLL FREE 877 742 2878 FOR SALES AND SUPPORT Retu...

Page 2: ...nd power cables The Power Supply Assembly means only the printed circuit board and the electronic or mechanical components located inside or on the power supply enclosure and the Pump head Assembly me...

Page 3: ...is Guide is to provide information to enable suitably qualified technicians and fitters to install operate and maintain the Micropump EagleDrive and common pump motor combinations Use the Guide when y...

Page 4: ...ow risk of external damage Hot Surfaces Under some operating conditions surface temperatures can exceed 90 C 195 F Do not touch products while operating Do not touch within 30 minutes of system shutdo...

Page 5: ...ews 4 supplied with the EagleDrive Torque screws to 0 8 N m 7 in lbs Loose bolts may result in pump motor misalignment Tighten bolts appropriately Pump motor misalignment may result in weakening the s...

Page 6: ...age source and the frequency counter if used will be forced to the same ground reference when connected to the EagleDrive Ensure only one earth ground is used to avoid ground loops Using The Tachomete...

Page 7: ...e the magnets inside the pump Ensure pump is correctly attached to EagleDrive 1 0 Internal Short Disabled Drive components have failed Reset EagleDrive by disconnecting and restoring power supply conn...

Page 8: ...the EagleDrive by first setting the external control signal input to the minimum value then switch off the power supply Check that the unit runs down in a steady manner Close the inlet and discharge v...

Page 9: ...mp periodically The pump cannot be drained completely a certain amount of liquid will remain in the magnet cup area Ensure that the pump is either flushed with a suitable flushing agent or precautions...

Page 10: ...Out lead is connected to the positive input of the frequency counter Check that the common lead of the frequency counter is connected to the motor Common lead Check leads to ensure no short circuits...

Page 11: ...Current Nominal Voltage 25 C Ambient 2 9A 24 VDC Speed Control 0 to 5 VDC Tachometer Out 0 to 5 VDC square wave 2 pulse per revolution Thermal Shutdown 135 C Thermal Restart 120 C Storage Temperature...

Page 12: ...8684 USA Tel 1 360 253 2008 Fax 1 360 253 8294 E mail info micropump idexcorp com Web www micropump com To purchase pumps parts or receive further information contact your local Micropump distributor...

Reviews: