background image

2

DOC No: 8540 REV E

3

DOC No: 8540 REV E

PUBLISHED BY

MICROPUMP INC.
A Unit of IDEX Corporation
December 2015 © Micropump Inc.

All rights reserved.
This manual contains proprietary information which is protected by copyright.
No part of this publication may be reproduced, transcribed, stored in a retrieval system, 
translated into any language (including computer language), or transmitted in any 
form without the written consent of the publisher. For further information contact your 
local Micropump distributor. Every effort has been made to ensure that the information 
contained in this manual is accurate prior to printing. However, the products described 
in this manual are subject to continuous development and improvement and Micropump 
shall not be liable for any errors contained herein or for incidental or consequential 
damages in connection with the furnishing, performance, or use of this manual.

STANDARD LIMITED WARRANTY 

 

The products manufactured by Micropump Incorporated are warranted to be free 
from defects in workmanship and material at the time of shipment from the place of 
manufacture.  Micropump will repair or replace, at its option, any part or component which 
fails to conform to this warranty for a period of one year.  Micropump’s obligation under 
this warranty is limited to the repairs or replacement of defective equipment returned to 
Micropump on an F.O.B. destination and freight-prepaid basis.  All normal wear and tear 
is excepted, and product is subject to examination at Micropump to verify that the parts or 
components were defective at the time of sale.

For the purposes of the limited warranties, the “Stator/Controller Assembly” means 
only the stator and the printed circuit board and electronic components contained in 
the controller housing, plus the connecting control and power cables.  The “Power 
Supply Assembly” means only the printed circuit board and the electronic or mechanical 
components located inside or on the power supply enclosure and the “Pump head 
Assembly” means all other parts of the product, including but not limited to, the rotor.

No warranty of any kind is made or shall be imposed with respect to any pump or parts 
(1) that have not been properly installed and tested in operation, (2) that have been 
subject to misuse, negligence, acts of God or the elements, or any other form of casualty, 
or (3) that have been repaired or altered outside Micropump’s facility in a way, so as, in 
our judgment, to affect performance or reliability.

The parties agree that the buyer’s sole and exclusive remedy against Micropump shall 
be for repair or replacement of defective parts under the conditions stated above.  The 
buyer agrees that no other remedy (including but not limited to incidental or consequential 
damages for lost pro

fi

 ts, lost sales, loss of use, injury to person or property, or any other 

incidental or consequential loss) shall be available to them.

This warranty shall not apply to prototype pumps, experimental pumps, or brush-type 
electric motors.  Warranty of equipment or accessories from outside sources, purchased 
by Micropump and incorporated into Micropump’s product is subject to the manufacturer’s 
standard warranty, unless speci

fi

 cally agreed otherwise between Micropump and buyer.  

A copy of the warranty on the aforementioned equipment is available on request.

The adjustment or replacement of defective parts made under this warranty will not 
extend the original warranty period.

THE WARRANTY DESCRIBED ABOVE IS THE EXCLUSIVE 
MICROPUMP WARRANTY AND IS IN LIEU OF ALL OTHER 
WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY 
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A 
PARTICULAR PURPOSE OR ANY WARRANTY PREVIOUSLY 
ISSUED.  WE NEITHER ASSUME NOR AUTHORIZE ANY PERSON 
TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION 
WITH THE SALE OR USE OF OUR EQUIPMENT.

Summary of Contents for MICROPUMP EagleDrive DEMSE

Page 1: ...STALLATION OPERATION AND WARRANTY INFORMATION EAGLEDRIVE TM EagleDriveTM DEMSE EagleDriveTM DEELE Without Enclosure Without Enclosure DEMSN DEELN CALL TOLL FREE 877 742 2878 FOR SALES AND SUPPORT Retu...

Page 2: ...nd power cables The Power Supply Assembly means only the printed circuit board and the electronic or mechanical components located inside or on the power supply enclosure and the Pump head Assembly me...

Page 3: ...is Guide is to provide information to enable suitably qualified technicians and fitters to install operate and maintain the Micropump EagleDrive and common pump motor combinations Use the Guide when y...

Page 4: ...ow risk of external damage Hot Surfaces Under some operating conditions surface temperatures can exceed 90 C 195 F Do not touch products while operating Do not touch within 30 minutes of system shutdo...

Page 5: ...ews 4 supplied with the EagleDrive Torque screws to 0 8 N m 7 in lbs Loose bolts may result in pump motor misalignment Tighten bolts appropriately Pump motor misalignment may result in weakening the s...

Page 6: ...age source and the frequency counter if used will be forced to the same ground reference when connected to the EagleDrive Ensure only one earth ground is used to avoid ground loops Using The Tachomete...

Page 7: ...e the magnets inside the pump Ensure pump is correctly attached to EagleDrive 1 0 Internal Short Disabled Drive components have failed Reset EagleDrive by disconnecting and restoring power supply conn...

Page 8: ...the EagleDrive by first setting the external control signal input to the minimum value then switch off the power supply Check that the unit runs down in a steady manner Close the inlet and discharge v...

Page 9: ...mp periodically The pump cannot be drained completely a certain amount of liquid will remain in the magnet cup area Ensure that the pump is either flushed with a suitable flushing agent or precautions...

Page 10: ...Out lead is connected to the positive input of the frequency counter Check that the common lead of the frequency counter is connected to the motor Common lead Check leads to ensure no short circuits...

Page 11: ...Current Nominal Voltage 25 C Ambient 2 9A 24 VDC Speed Control 0 to 5 VDC Tachometer Out 0 to 5 VDC square wave 2 pulse per revolution Thermal Shutdown 135 C Thermal Restart 120 C Storage Temperature...

Page 12: ...8684 USA Tel 1 360 253 2008 Fax 1 360 253 8294 E mail info micropump idexcorp com Web www micropump com To purchase pumps parts or receive further information contact your local Micropump distributor...

Reviews: