Page 8
0901180 Rev: B (09/16)
SYSTEM PROGRAMMING
The system operates using a 4 button key design. The
key functions are controlled via the firmware and are
specific to each screen. The main 4 keys are MENU,
UP, DOWN and ENTER. The ENTER key is used to
move the cursor and select within the menu functions.
The UP and DOWN arrows are used to change a
value. Changed values will be saved upon exiting the
current menu function. The screen has 4 colors to
easily identify the system status.
BLUE - Run Mode
PURPLE - Programming Mode
GREEN - Performing a Function
RED - Error Display
Accessing the Programming Menus
When power is first applied you will see the screen
showing the CONTROL GUARD name along with USB
and firmware versions. You will then see the main run
screen which shows the status of any pump action.
Press the MENU button to access the settings menu.
Press the ▼ key to highlight CONFIGURATION. Press
the ENTER key.
Password Protection
A private password protects the system settings and
allows only authorized personnel to make
programming changes.
To enter a private password, press ENTER key to
move the cursor, then UP or DOWN to change the
value. Once you press ENTER after the last digit it will
take you to the next screen. The default code is: 0000.
If the wrong password is entered it will take you back to
the main run screen. If you have forgotten your
password, you can call Knight and give them the 4 digit
bypass code and they can give you a one-time
password.
CONTROL
GUARD
USB VERSION 1.0
FIRMWARE VERSION 1.0
MAIN:V1.00 I/O:V1.00
ENTER PASSWORD
—————————————————
0000
▲
3988
______________________________
▲ | ▼ | EXIT | ENTER
11:42:12
10/13/2015
PUMP 1
______________________________
| IDIOMA | MENU |
PRIME PUMPS
►
CONFIGURATION
DIAGNOSTICS
______________________________
▲ | ▼ | EXIT | ENTER
4 digit bypass code
Summary of Contents for Knight Control Guard ACCS
Page 1: ...0901180 Rev B 09 16 Page 1 Control Guard ACCS Instruction Manual...
Page 34: ...Page 34 0901180 Rev B 09 16 SYSTEM DIMENSIONS Main Cabinet all models...
Page 35: ...0901180 Rev B 09 16 Page 35 WIRING DIAGRAM 115VAC...
Page 36: ...Page 36 0901180 Rev B 09 16 WIRING DIAGRAM 230VAC...
Page 37: ...0901180 Rev B 09 16 Page 37 WIRING DIAGRAM FOR CONNECTING SIGNAL INPUTS...
Page 38: ...Page 38 0901180 Rev B 09 16 WIRING DIAGRAM FOR CONNECTING REMOTE INPUT SIGNALS...
Page 40: ...Page 40 0901180 Rev B 09 16 WIRING DIAGRAM FOR CONNECTING KNIGHT INDUCTIVE PROBES PN 6536033...
Page 41: ...0901180 Rev B 09 16 Page 41 WIRING DIAGRAM FOR CONNECTING A 4 20MA DEVICE...
Page 43: ...0901180 Rev B 09 16 Page 43 EXPLODED VIEWS...
Page 44: ...Page 44 0901180 Rev B 09 16 EXPLODED VIEWS...
Page 45: ...0901180 Rev B 09 16 Page 45 EXPLODED VIEWS...
Page 46: ...Page 46 0901180 Rev B 09 16 EXPLODED VIEWS...
Page 47: ...0901180 Rev B 09 16 Page 47 EXPLODED VIEWS...
Page 48: ...Page 48 0901180 Rev B 09 16 EXPLODED VIEWS...
Page 49: ...0901180 Rev B 09 16 Page 49 EXPLODED VIEWS...
Page 51: ...0901180 Rev B 09 16 Page 51...