background image

Motor Control
It is your responsibility to contact a qualified
electrician and assure that the electrical installation is
adequate and in conformance with all national and
local codes and ordinances.

Select fuses, motor protective switches or thermal
protective switches to provide protection.  Fuses act as
short circuit protection for the motor, not as protection
against overload.  Incoming line fuses must be able to
withstand the motor’s starting current.  Motor starters with
thermal magnetic overload or circuit breakers protect
motor from overload or reduced voltage conditions.  If
additional information is required, please consult your
Gast Distributor/Representative.

The wiring diagram supplied with the product provides
required electrical information.  Check that power source
is correct to properly operate the dual-voltage motors.

Your safety and the safety of others

is extremely important.

We have provided many important safety messages
in this manual and on your product. Always read
and obey all safety messages.

This is the safety alert symbol. This symbol

alerts you to hazards that can kill or hurt you and
others. The safety alert symbol and the words
“DANGER” and “WARNING” will precede all safety
messages. These words mean:

You will be killed or seriously injured if you don’t
follow instructions.

You can be killed or seriously injured if you don’t
follow instructions.

All safety messages will identify the hazard, tell you
how to reduce the chance of injury, and tell you
what can happen if the safety instructions are not
followed.

Correct installation is your responsibility. Make sure
you have the proper installation conditions and that
installation clearances do not block air flow.

Blocking air flow over the product in any way can
cause the product to overheat.

Mounting
This product can be installed in any orientation.
Mounting the product to a stable, rigid operating surface
and using shock mounts will reduce noise and vibration.

INSTALLATION

Accessories
Filters and mufflers are supplied with some models.
These should be checked periodically and replaced
when necessary.  An optional liquid trap should be
installed between the line and the intake filter if this unit
will be operated in a wet application.  Please consult
your Gast Distributor/Representative for additional filter
recommendations.

WARNING

DANGER

c

Disconnect electrical power at the circuit breaker
or fuse box before installing this product.

Install this product where it will not come into
contact with water or other liquids.

Install this product where it will be weather
protected.

Electrically ground this product.

Failure to follow these instructions can result in
death, fire or electrical shock.

WARNING

Electrical Shock Hazard

Plumbing
Remove plugs from the IN and OUT ports.  Be sure to
connect the intake and exhaust plumbing to the correct
inlet and outlet ports.  Ports will not support the
weight of the plumbing.

Check valves may be required to prevent back
streaming through the pump.

Electrical Connection

c

This product must be properly grounded.

Do not modify the plug provided. If it will not
fit the outlet, have the proper outlet installed
by a qualified electrician.

If repair or replacement of the cord or plug is
necessary, do not connect the grounding wire
to either flat blade terminal. The wire with
insulation that is green with or without yellow
stripes is the grounding wire.

Check the condition of the power supply wiring.
Do not permanently connect this product to
wiring that is not in good condition or is 
inadequate for the requirements of this product.

Failure to follow these instructions can result in
death, fire or electrical shock.

WARNING

Electrical Shock Hazard

2

Summary of Contents for Gast DOA Series

Page 1: ... Consult your Gast Distributor Representative before using at high altitudes This pump is oil less and requires NO lubrication Laboratory units may be used for both pressure and vacuum IMPORTANT PLEASE READ THIS MANUAL AND SAVE FOR FUTURE REFERENCE Thank you for purchasing this Gast product It is manufactured to the highest standards using quality materials Please follow all recommended maintenanc...

Page 2: ...y way can cause the product to overheat Mounting This product can be installed in any orientation Mounting the product to a stable rigid operating surface and using shock mounts will reduce noise and vibration INSTALLATION Accessories Filters and mufflers are supplied with some models These should be checked periodically and replaced when necessary An optional liquid trap should be installed betwe...

Page 3: ...cal codes and ordinances Grounded Plug Grounding Pin Grounded Outlet 120 volt grounded connectors shown 220 240 volt grounded connectors will differ in shape G Model that is permanently wired This product must be connected to a grounded metallic permanent wiring system or an equipment grounding terminal or lead on the product Power supply wiring must conform to all required safety codes and be ins...

Page 4: ...fore handling Air stream from product may contain solid or liquid material that can result in eye or skin damage wear proper eye protection Clean this product in a well ventilated area Failure to follow these instructions can result in burns eye injury or other serious injury WARNING Check intake and exhaust filters after first 500 hours of operation Clean filters and determine how frequently filt...

Page 5: ...PRESSLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE OR PURPOSE WITH RESPECT TO THE GOODS SOLD THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTIONS SET FORTH IN THIS WARRANTY notwithstanding any knowledge of Gast regarding the use or uses intended to be made of goods proposed changes or additions to goods or any assistance or suggestions that may have been made...

Page 6: ...AF809 16 DIAPHRAGM 1 AF818A AF818A 17 FELT SPACER 3 AA929 AA929 18 SPACER 1 AD996 AD996 19 FAN 1 AT837 AT837 20 GRILLE 1 AF807 AF807 21 RUBBER FOOT 4 AF584A AF584A 22 POWER CORD 1 AE941 AG320 23 REAR COVER 1 AF805B AG954 24 VALVE PLATE ASSEMBLY 1 AP519 AP519 25 RETAINER PLATE SCREWS 2 BB557 BB557 SERVICE KIT 1 K294J K294K DOA SERIES Please reference the exploded view on the next page for the follo...

Page 7: ...EXPLODED PRODUCT VIEWS MODEL DOA VALVE PLATE ASSEMBLY Valve Plate Assembly available separately Valve Plate Assembly also includes items 10 13 not shown 7 ...

Page 8: ...lves bent Clean or replace Worn diaphragm Repair or replace Relief valve set too high Inspect and adjust Relief valve set too low Inspect and adjust At pump At pump Plugged vacuum pressure line Inspect and repair At pump Collapsed vacuum line Inspect and repair Low voltage won t start Check power source Voltage wrong Check power source Worn diaphragm Replace Leaky hose or check valve Replace Dirt ...