TROUBLESHOOTING CHART
www.gastmfg.com
ISO 9001 & 14001 CERTIFIED
inc.
PART NO. 70 - 5105 G471PL (Rev A)
8
Low
High
Pump
Motor
Excess
Reason and remedy
Vacuum
Pressure
Vacuum
Pressure
Overheat
Overload
Noise
for problem.
•
•
At Pump
•
•
Filter dirty. Clean or replace.
•
•
At pump
•
•
Muffler dirty. Clean or replace.
•
•
Valves dirty or valves bent.
Clean or replace.
•
•
Worn diaphragm.
Repair or replace.
•
•
•
Relief valve set too high.
Inspect and adjust.
•
•
Relief valve set too low.
Inspect and adjust.
•
•
At pump
At pump
•
•
Plugged vacuum/pressure line.
Inspect and repair.
•
At pump
Collapsed vacuum line.
Inspect and repair.
•
•
Low voltage, won’t start.
Check power source.
•
•
•
Voltage wrong.
Check power source.
•
•
•
Worn diaphragm.
Replace.
•
•
Leaky hose or check valve.
Replace.
•
•
•
•
•
Dirt or liquid on top of diaphragm.
Inspect and clean.
•
•
•
•
Motor not wired correctly.
Check wiring diagram/line voltage.