6.2  Firmware Update 

The firmware is stored in a FLASH memory and can be updated if needed. 

6.3  Spare Parts 

 

Recommended spare parts stock  

In order to minimize the downtime in the event of a malfunction, it is recommended to have certain spare parts on 
stock. For larger systems with more than 15 iPOINTs, doubling of the recommended stock quantity is 
recommended. 
 
Furthermore, it is advised to have several spare ILR

®

 Tags in stock, corresponding to approx. 0.5 – 1 % of the total 

number of ILR

®

 Tags. 

 

Preparing the spare parts 

In general, all spare parts can be used immediately upon delivery from IDENTEC SOLUTIONS. However, for the 
iPOINT there are various settings of the communication parameters. 
In order to keep down times short it is recommended that these parameters are set before the component is 
entered into the spare part stock system. In most cases all units within an identification system are used in the 
same way so that only one setting is required. 
 

Examination and repair of exchanged parts  

The data ILR

®

 Tags and iPOINT X devices are complex electronic power units on which the customer can carry out 

only very limited repairs. Normally the repairs are carried out at IDENTEC SOLUTIONS or possibly at a distributor. 
Before a part is sent in for repair a short examination should be conducted. 
 

6.4  Returns  

Parts or main components returned for repair or exchange must be handled with great care. All returns should 
include an error description and a short application overview and be sent to the local distributor or to: 
 

IDENTEC SOLUTIONS AG 
Service Department 
Millennium Park 2 
6890 Lustenau 
AUSTRIA 

 

For full details, refer to our “Return and Repair Policy” on our website

 

Summary of Contents for iPOINT Si

Page 1: ...IDENTEC SOLUTIONS Model IDS1001 iPOINT Si HARDWARE USER MANUAL...

Page 2: ...y person for any special incidental indirect or consequential damages including without limitation damages resulting from use of or reliance on information presented herein or loss of profits or reven...

Page 3: ...nded This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Conformit l exposition aux champs RF des quipements radio Pour satisfaire aux exigences F...

Page 4: ...crew on the unit Best practice is to use an antistatic ribbon and earth yourself permanently for the time you handle the unit Avoid unnecessary contact with the unit connectors and assemblies inside t...

Page 5: ...d cool environments Do not open the Main housing The Connection Chamber can be opened for required cabling needs but there is no need to open the main housing crews from bottom side in order to set th...

Page 6: ...SB Connector Pinout 15 2 4 USB Only mode Function and specification 16 2 5 Communication Interface Priorities 16 2 6 Lid Open Detection 16 3 Initial Operation Configuration 17 3 1 Status LEDs 17 4 Mec...

Page 7: ...the content contained herein It is the user s responsibility to contact the service department for any possible changes or updates to operating and maintenance procedures Updates will be provided upo...

Page 8: ...e Housing contains 5 Status LEDs see Section 3 1 a Connection Chamber where the wired interfaces can be accessed Relevant cable glands as wired access points depending on the device setup Mounting Pla...

Page 9: ...cols The iPOINT X has two internal UHF antennas built in and can communicate up to a range of 500 meters with its Tags The main benefit of two antennas is the elimination of RF dead spots in static sy...

Page 10: ...reserved 10 2 1 3 NFC Interface The NFC Interface is a Near Field Communication interface The iPOINT can be used as an entry terminal or for other NFC communication The range to the Tag is around 10 1...

Page 11: ...racking and Tracing Localization Environmental Data Sensing i B350 Tags IDENTEC SOLUTIONS i B350 tags are designed to be cost effective and easy to implement while offering maximum flexibility The bea...

Page 12: ...or for debugging low power operation and device configuration RS422 MASTER RJ45 RS422 cable connector to the host computer or previous Slave port in the daisychain RS422 SLAVE RJ45 RS422 cable connect...

Page 13: ...d 13 RS422 with injected 24V Power installation Make sure power supply can handle all iPOINTs in the system USB Mode 5V Local USB mode over Mini USB Connector for debugging low power operation and Con...

Page 14: ...units in the chain must not exceed 1000 m 3200 ft The distance from one unit to the next must not exceed 300 m 1000 ft This table is valid for Cat 5 cabling with gauge diameters of AWG24 0 25 mm of i...

Page 15: ...r bus 8 GND GND Brown Power supply over bus As the TxD RxD crossing is done by the pinout of the connectors simple straight cabling has to be used Connection parameters Signal levels RS422 Baud rate 1...

Page 16: ...ver TBD Enter config debugging info 2 5 Communication Interface Priorities The priorities for the wired connections will be 1 USB Highest priority A connection over USB will terminate all other existi...

Page 17: ...Orange when a response or a broadcast is received LF This is the LF Communication LED LED blinks green when Marker Loop ID is sent It blinks red if LF is not working properly e g loop broken or loop...

Page 18: ...from the front side until magnetic connection is released lift off 2 Loosen the 8x screws be aware DO NOT pull out the screws out completely the gasket can be damaged 3 Lift off the lid 4 Now you hav...

Page 19: ...ting plate only 4x countersunk screws are required with a maximum diameter of 5mm or M5 screws Length and type shall be chosen depending on wall material 4x countersunk screws Choose screw type and le...

Page 20: ...here s a risk of damage 4 2 1 Optional Extra Pole Mount Bracket Kit A Pole Mount Bracket Kit is available Pole Mount Bracket Kit o Contains the bracket and accessories o The bracket can be mounted to...

Page 21: ...xtension Bracket Kit is available Extension Bracket Kit o Contains the bracket and accessories o The bracket can be mounted to a wall with M8 Bolts or via threaded rods e g wall anchors o Multiple mou...

Page 22: ...iPOINT Hardware User Manual 18 06 2020 Copyright 2020 IDENTEC SOLUTIONS All rights reserved 22...

Page 23: ...epends on the relevant system concept and very likely varies from one system to another A Brief Checklist Are all housings intact Are all cables intact Are all connectors intact Are all connectors sec...

Page 24: ...order to keep down times short it is recommended that these parameters are set before the component is entered into the spare part stock system In most cases all units within an identification system...

Page 25: ...Interface USB USB Mini Status Display 5 LEDs UHF LF COM RUN NFC Electrical Power Source PoE 12 30VDC RS422 Master Power Consumption according to 802 3af3 Max 7 Watt Environmental Conditions Operating...

Page 26: ...iPOINT Hardware User Manual 18 06 2020 Copyright 2020 IDENTEC SOLUTIONS All rights reserved 26...

Reviews: