2 Operational Check
3 Window and Menu
4 Appendix
1 Overview
4-2
Troubleshooting
4. 1. 3
Cannot connect to the WB2F Support Tool because the WB2F RS-232 settings were forgotten
On the Connection settings screen, select the communication port to which the WB2F is connected, and then
click Connect automatically.
The support tool automatically searches for the communication settings that the WB2F is set to.
This may take some time. (The maximum time: About 1 min 30 sec.)
Check the communication settings from maintenance mode.
1
Switch to maintenance mode.
(Refer to the WB2F user’s manual.)
2
Start the WB2F Support Tool and click Connection with the default settings.
• Default settings
Speed
9600 bps
Flow control
None
Data length
8
Prefix
5E,00,00,00
Parity
EVEN
Suffix
0D,0A,00,00
Stop bits
1
Check digit
None
3
Double-click Console to open the Console screen.
4
Enter “comgetm” and click Send.
* Select only the Pref. ON and Suf. ON check boxes.
5
Check the communication settings that are set on the WB2F from the response results (red).