IDEC SmartRelay functions
180
IDEC SmartRelay Manual
Functional description
Output Q changes its status, i.e. the output is set or reset,
with each 0 to 1 transition at input Trg and if the inputs S and
R = 0.
The signal at input Trg does not influence the special func-
tion when S or R = 1.
You set the current impulse relay with a signal at input S, i.e.
the output is set hi.
You reset the current impulse relay with a signal at input R,
i.e. the output is set lo.
Status diagram
*: RS or SR
**: Triggering signal is effective, because S and R = 0.
Par
Q
n-1
S
R
Trg
Q
n
*
0
0
0
0
0
*
0
0
0
0 ->1
1
**
*
0
0
1
0
0
*
0
0
1
0 ->1
0
*
0
1
0
0
1
*
0
1
0
0 ->1
1
RS
0
1
1
0
0
RS
0
1
1
0 ->1
0
SR
0
1
1
0
1
SR
0
1
1
0 ->1
1
*
1
0
0
0
1
*
1
0
0
0 ->1
0
**
*
1
0
1
0
0
*
1
0
1
0 ->1
0
*
1
1
0
0
1
*
1
1
0
0 ->1
1
RS
1
1
1
0
0
RS
1
1
1
0 ->1
0
SR
1
1
1
0
1
SR
1
1
1
0 ->1
1
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com