Troubleshooting of emitter
<All indicators are OFF>
Cause
Remedy
Power is not being supplied.
Check that the power supply capacity is sufficient. Connect the
power supply correctly.
Supply voltage is out of the specified range.
Set the supply voltage correc ly.
Connector is not connected securely.
Connect the connector securely.
<Fault indicator (yellow) lights up or blinks>
Cause
Remedy
[Digital error indicator:
]
Setting data error of this device
Series connection is in-correct.
Check that the cable for series connection does not short-circuit, or is con-
nected to the correct position (emitter for emitter, receiver for receivers).
Incase the handy controller
SE9Z-HC
(optional) is applied, reset the function.
Noise is out of the specified range.
Check the noise status around this device.
If the handy controller
SE9Z-HC
(optional) is used, reset the function.
Internal error
Contact our office.
[Digital error indicator:
]
System error between emitter and receiver
Systems are different between emitter
and receiver.
Set the same value to the number of beam channels of emitter and
receiver and the output polarity setting wire (shield).
[Digital error indicator:
]
Series connection error
The serial signal short-circuits or comes
down.
Check if the end cap has been fitted properly.
Check that the cable for series connection does not short-circuit, or is con-
nected to the correct position (emitter for emitter, receiver for receiver). Check
the error contents of the device connected by the cable for series connection.
Any of the main / sub sensor is in error.
[Digital error indicator:
]
No. of total units / No. of total beam chan-
nels error
No. of total units / No. of total beam
channels is out of the specified range.
Set the condi ion of the series connection wi hin the specification.
[Digital error indicator:
]
Interlock setting error
Voltage level of interlock setting input
wire (pale purple) or emission halt input
/ reset input wire (pink) is unstable.
Wire the interlock set ing input wire (pale purple) and emission halt
input / reset input wire (pink) correctly.
[Digital error indicator:
, ]
Muting lamp error
Muting lamp output wire (red) short-
circuits with 0V or +V.
Wire the muting lamp output wire (red) correctly.
Current value should be wi hin the specified muting lamp output.
Muting lamp output short-circuits with
other I/O wires.
Excessive incoming cur-rent flows in the
muting lamp output.
Output polarity setting wire (shield) and
muting lamp output wire (red) are not
correctly wired.
Wire the output polarity setting wire (shield) correctly.
(0V: PNP output, +V: NPN output)
Wire the muting lamp output wire (red) to +V.
Output circuit error.
Output circuit is damaged. Replace this device.
[Digital error indicator:
]
Wiring error of the output polarity setting
wire (shield)
Output polarity setting wire (shield) comes
down or short-circuits with other I/O wires.
Output polarity setting wire (shield) con-
nection of emitter / receiver is incorrect.
Wire the output polarity setting wire (shield) correctly.
(0V: PNP output, +V: NPN output)