3-22
■
Web Server Unit Settings
Follow the procedure below to make the Web Server Unit settings.
●
Switching Web Server Unit Mode
Turn the Web Server Unit’s mode selection switch to “USER”.
* The default setting of the Web Server Unit’s mode selection switch is “REMOTE”.
3_4_3_Toggle_Switch_E
Function selector switch
USER
Make the switch the “USER”!
REMOTE
Performing Ethernet user communication between MicroSmart modules
To perform Ethernet user communication between MicroSmart modules, the only operation needed
for the Web Server Unit on the TCP protocol server is to set the mode selection switch to “USER”.
The rest of the setting procedure is given in the description of the TCP protocol client settings.
●
Opening Web Server Unit System Setting Screen
Open the Web Server Unit’s settings screen.
There are two ways to open this screen:
1)
Opening settings screen from WindLDR (see “System Setting Screen” in Section 1 of Chapter 3 for more information)
1. Select [Setting Web Server Unit] in WindLDR.
2. The previously set IP address appears in the WindLDR screen.
3. Double-click the IP address of the Web Server Unit performing Ethernet user communication. The Web
browser starts, and the System Setting Screen as below appears.
2)
Opening settings screen directly from Web browser
1. Start the Web browser.
2. In the Web browser’s address bar, enter the IP address of the Web Server Unit performing Ethernet user
communication, and press the Web browser’s [Refresh] button or the keyboard’s Enter key.
3. The System Setting Screen appears.
NOTE
3_4_5_System_Setting_E
System Setting Screen