INSTRUCTION SHEET - HS6E Series 

Solenoid Type Safety Switch

( 1 / 6 )

2016.08

1

Type

2

Specifications and Ratings

CAUTION

Solenoid lock type

• This safety switch is designed to lock the actuator while the solenoid is energized 

and to release it when deenergized.

• When the power to the solenoid is interrupted by accident, such as disconnection, 

the lock is released before a machine stops ompletely. Then, the worker may be 

exposed to hazards. 

• This safety switch can be used only for limited applications which do not especially 

need to be locked for safety.

Ratings approved by safety agencies

(1)

 

TÜV rating

  Main circuit, Look monitor circuit

    AC-15 125V/1A

    DC-13 125V/0.22A

    DC-13 30V/1A
  Door monitor circuit

    AC-15 240V/0.75A

    DC-13 250V/0.27A

    DC-13 30V/2.3A

(4) KOSHA rating
  Main circuit, Look monitor circuit

    AC-15 125V/1A

    DC-13 125V/0.22A
  Door monitor circuit

    AC-15 240V/0.75A

    DC-13 250V/0.27A

(2) UL, c-UL rating
  Main circuit,

 

Look monitor circuit

    1A, 125V ac, Pilot Duty

    0.22A, 125V dc, Pilot Duty

    1A, 30V dc, Pilot Duty
  Door monitor circuit

    C300  0.75A, 240V ac, Pilot Duty

    Q300  0.27A, 250V dc, Pilot Duty

(3) CCC rating
  Main circuit, Look monitor circuit

    AC-15 125V/1A

    DC-13 30V/1A
  Door monitor circuit

    AC-15 240V/0.75A

    DC-13 30V/2.3A

*1  Basic insulation of 2.5kV, 1.5kV impulse withstand voltage is ensured between 

different contact circuits and between contact circuits and LED or solenoid in  he 

enclosure. When both SELV (safety extra low voltage) or PELV (protective extra 

low voltage) circuits and other circuits (such as 230V AC circuits) are used for  he 

solenoid power and contact circuits at the same time, the SELV or PELV 

requirements are not met any more.

*2  The actuator locking strength is rated at 500N of static load. Do not apply a load 

higher than the rated value. When a higher load is expected to work on the 

actuator, provide an additional system consisting of another safety switch without 

lock (such as the HS6B/HS7A safety switch) or a sensor to detect door opening 

and stop the machine.

*3  F1max. is maximum force. The actuator’s guard-locking force Fzh is calculated in 

accodance with GS-ET-19:

*4 Make sure that a fast acting fuse for short-circuit protection trips before 

overheating of the wires. 

    

Main 

Door Monitor  Lock Monitor

    

Circuit 

Circuit 

Circuit

  L :  1NC+1NC 

2NC 

1NO

  M :  1NC+1NC 

2NC 

1NC

  N :  1NC+1NC  1NC, 1NO 

1NO

  P :  1NC+1NC  1NC, 1NO 

1NC

 VL : 

 

3NC 

1NC, 1NO

 VM  : 

 

3NC 

2NC

 VN : 

 

2NC, 1NO 

1NC, 1NO

 VP  : 

 

2NC, 1NO 

2NC

Solenoid Voltage / Lock Mechanism

 

4 : 24V DC / Spring Lock

  7Y : 24V DC / Solenoid Lock

Indicator Voltage

 

4 : 24V DC

Cable Length

  01 : 1m

  03 : 3m

  05 : 5m

Pilot Light Color 

 

G : Green

Circuit Code

HS6E-L44B01-G

Housing Color

 

B : Black

Confirm that the delivered product is what you have ordered. 

Read  his instruction sheet to make sure of correct operation.

In this operating instruction sheet, safety precautions are categorized to Warning and 

Caution:

Warning notices are used to emphasize that improper operation may cause severe 

personal injury or death.

Caution notices are used where inattention might cause personal injury or damage to 

equipment.

INSTRUCTION SHEET

Original Instructions

Solenoid Type Safety Switch

HS6E Series

S A F E T Y   P R E C A U T I O N S

CAUTION

WARNING

* In order to verify if the product 

you are interested in is certified 

with the S mark, please check 

the following section on our 

website: "List of type numbers 

certified with the S mark"

(Main circuit

Door monitor circuit)

Interlocking device Type

 /the level of coded

Type 2 Interlocking device

/ low level coded actuator (EN ISO / ISO14119)

Resistive load

(AC-12)
Inductive load

(AC-15)

 

 

 

 

 

 

AC

Main 

Circuit,

Look

monitor

circuit

 30V 

125V  250V

 - 

2A 

-

 - 

1A 

-

   

 

   

 

   

 

   

 

 

 

 

 

 

 

 ‹Ue, Ie›

Contact Ratings

Thermal Current ‹Ith›

Rated Insulation voltage ‹Ui›

Impulse withstand voltage ‹Uimp›

Altitude

Pollution degree   

Operating Humidity

Condition

Operating Temperature

Applicable Directives

Standards for Use

Applicable Standards

   0.5A (≥ 2 circuits)

   1.0A (1 circuit)

35°C ≤ Operating temperature ≤ 50°C

   1.0A (≥ 3 circuits) 

   2.5A (≤ 2 circuits)

-25°C ≤ Operating temperature < 35°C

30V(Between ground and LED,solenoid circuit) 

300V(Door monitor circuit)

150V(Main,Lock monitor circuit)

0.5kV(Between ground and LED,solenoid circuit) 

2 5kV(Door monitor circuit)

1 5kV(Main,Lock monitor circuit)

2,000m maximum

3(Inside 2)

45 to 85%RH(no condensation)

-25 to +50°C (no freezing)

Machinery Directive, Low Voltage Directive

IEC60204-1, EN60204-1

GS-ET-19, UL508, CSA C22.2 No.14

IEC60947-5-1, EN60947-5-1

EN ISO / ISO14119, GB14048.5

Fzh  

 =

maximum force (F1max.)

Safety coefficient (=1.3)

Rated Power Consumption

Illumination Color

Light Source

Turn OFF Voltage

Turn ON Voltage

Rated Current

Rated Operating Voltage

 

 

Resistive load

(DC-12)
Inductive load

(DC-13)
Resistive load

(AC-12)
Inductive load

(AC-15)
Resistive load

(DC-12)
Inductive load

(DC-13)

DC

AC

DC

Door

monitor

circuit

 

 

 

 

   

 

-

   

 

 2A 

0.4A 

-

 1A  0.22A 

-

 - 

2.5A  1.5A

 - 

1.5A  0.75A

 2.5A  1.1A  0.55A

 2.3A  0.55A  0.27A

Approx. 2.7W

Green

LED

Rated voltage x 10% minimum (at 20°C)

Rated voltage x 85% maximum (at 20°C)

110 mA (solenoid 100mA, LED 10mA : initial value)

DC24V 100% duty cycle

Rated Operating Voltage

DC24V 100% duty cycle

Use 250V / 10A fast acting type fuse 

*4

50A (250V)

NEMA Type12 (operating temp. -25 to 45°C)

IP67 (IEC60529)

300 m Ω maximum (initial value, 1m cable)

60 N minimum

8 mm minimum

    24V AC/DC  0.1A Resistive Load)

  (900 operations / hour,

1,000,000 operations minimum.

    AC-12 125V 2A, DC-12 125V 0.4A)

  (900 operations / hour,

100,000 operations minimum.

1,000,000 operations minimum. (GS-ET-19)

2,000,000 (EN ISO 13849-1 AnnexC Table C.1)

0.05 to 1.0 m/s

900 operations/hour

Class 

II

 (IEC61140) *1

Short-circuit Protective Device

Conditional short circuit current

Degree of Protection

Contact Resistance

Direct Opening Force

Direct Opening Travel

Actuator Tensile Strength

when Locked

Electrical Durability

Mechanical Durability

B10d

Operating Speed

Operating Frequency

Class of Protection

Shock Resistance

Vibration Resistance

Operating Extremes: 100m/s

2

, Damage Limits: 1,000m/s

2

Operating Extremes:10 to 55 Hz, half amplitude 0.35mm 

Damage Limits: 30 Hz, half amplitude 1 5mm
Fzh=500N minimum   

F1max.=650N minimum (GS-ET-19)  *2, *3

(Fzh=100N minimum: HS9Z-A62 actuator)   

Solenoid

Indicator

Summary of Contents for HS6E Series

Page 1: ...y or death Caution notices are used where inattention might cause personal injury or damage to equipment INSTRUCTION SHEET Original Instructions Solenoid Type Safety Switch HS6E Series S A F E T Y P R E C A U T I O N S CAUTION WARNING In order to verify if the product you are interested in is certified with the S mark please check the following section on our website List of type numbers certified...

Page 2: ...the safety switch the actuator moves within the range shown below HS9Z A61 A62 A65 A66 4 1mm maximum from the safety switch surface HS9Z A62S 3 5mm maximum from the safety switch surface The open close status of the contacts are maintained within the range When a gap is caused because of actuator relocation make sure that the gap does not lead to new risks 1 0mm 6 1 0mm 5 Entry Direction 1 9mm 7 W...

Page 3: ...distorted during operation Make sure that no foreign objects are caught between the safety switch and mounting surface Uneven surface distorted surface or foreign objects may result in the malfunction of safety switch For Manual Unlocking Spring lock type The HS6E allows manual unlocking of the actuator to precheck proper door operation before wiring or turning power on as well as for emergency us...

Page 4: ...sed Closed Closed Closed Closed Closed Closed Wiring Cable specifications UL style 2464 12c No 22AWG 80 C 300V Wire identification Wires are identified by the color and white line printed on the wire Do not use wire which is Gray Gray White Terminal number identification When wiring the terminal number on each contact is identified by wire color The following table shows the identification of term...

Page 5: ... he machine equipment manufacturer to have applied the fault exclusion based on ISO13849 1 ISO13849 2 or IEC62061 Output Circuit Output Circuit S1 HS6E P4 Safety Switch with Solenoid S2 Starting Switch HW Series Momentary S3 Unlocking Enabling Switch S4 Safety limit Switch ESC Outside start condition K3 4 Safety Contactor F1 Outside fuse of safety relay module at power supply line Note Use the mon...

Page 6: ...e insertion direction of the joint white plastic part See the figures below Do not lose the joints Actuators do not operate normally without a joint Horizontal Adjustment Vertical Adjustment Factory defalut Joint Accessories dimensions supplied Φ10 6 5 24 24 5 18 3 9 15 22 6 1 14 0 8 6 2 42 to 42 5 20 5 41 8 28 5 30 LED 0 8 15 20 1 37 15 C 1 2 20 5 2 3 41 8 28 5 46 1 10 4 10 1 12 6 1 5 14 4 4 R 2 ...

Reviews: