INSTRUCTION SHEET - HS6E Series
Solenoid Type Safety Switch
( 1 / 6 )
2016.08
1
Type
2
Specifications and Ratings
CAUTION
Solenoid lock type
• This safety switch is designed to lock the actuator while the solenoid is energized
and to release it when deenergized.
• When the power to the solenoid is interrupted by accident, such as disconnection,
the lock is released before a machine stops ompletely. Then, the worker may be
exposed to hazards.
• This safety switch can be used only for limited applications which do not especially
need to be locked for safety.
Ratings approved by safety agencies
(1)
TÜV rating
Main circuit, Look monitor circuit
AC-15 125V/1A
DC-13 125V/0.22A
DC-13 30V/1A
Door monitor circuit
AC-15 240V/0.75A
DC-13 250V/0.27A
DC-13 30V/2.3A
(4) KOSHA rating
Main circuit, Look monitor circuit
AC-15 125V/1A
DC-13 125V/0.22A
Door monitor circuit
AC-15 240V/0.75A
DC-13 250V/0.27A
(2) UL, c-UL rating
Main circuit,
Look monitor circuit
1A, 125V ac, Pilot Duty
0.22A, 125V dc, Pilot Duty
1A, 30V dc, Pilot Duty
Door monitor circuit
C300 0.75A, 240V ac, Pilot Duty
Q300 0.27A, 250V dc, Pilot Duty
(3) CCC rating
Main circuit, Look monitor circuit
AC-15 125V/1A
DC-13 30V/1A
Door monitor circuit
AC-15 240V/0.75A
DC-13 30V/2.3A
*1 Basic insulation of 2.5kV, 1.5kV impulse withstand voltage is ensured between
different contact circuits and between contact circuits and LED or solenoid in he
enclosure. When both SELV (safety extra low voltage) or PELV (protective extra
low voltage) circuits and other circuits (such as 230V AC circuits) are used for he
solenoid power and contact circuits at the same time, the SELV or PELV
requirements are not met any more.
*2 The actuator locking strength is rated at 500N of static load. Do not apply a load
higher than the rated value. When a higher load is expected to work on the
actuator, provide an additional system consisting of another safety switch without
lock (such as the HS6B/HS7A safety switch) or a sensor to detect door opening
and stop the machine.
*3 F1max. is maximum force. The actuator’s guard-locking force Fzh is calculated in
accodance with GS-ET-19:
*4 Make sure that a fast acting fuse for short-circuit protection trips before
overheating of the wires.
Main
Door Monitor Lock Monitor
Circuit
Circuit
Circuit
L : 1NC+1NC
2NC
1NO
M : 1NC+1NC
2NC
1NC
N : 1NC+1NC 1NC, 1NO
1NO
P : 1NC+1NC 1NC, 1NO
1NC
VL :
3NC
1NC, 1NO
VM :
3NC
2NC
VN :
2NC, 1NO
1NC, 1NO
VP :
2NC, 1NO
2NC
Solenoid Voltage / Lock Mechanism
4 : 24V DC / Spring Lock
7Y : 24V DC / Solenoid Lock
Indicator Voltage
4 : 24V DC
Cable Length
01 : 1m
03 : 3m
05 : 5m
Pilot Light Color
G : Green
Circuit Code
HS6E-L44B01-G
Housing Color
B : Black
Confirm that the delivered product is what you have ordered.
Read his instruction sheet to make sure of correct operation.
In this operating instruction sheet, safety precautions are categorized to Warning and
Caution:
Warning notices are used to emphasize that improper operation may cause severe
personal injury or death.
Caution notices are used where inattention might cause personal injury or damage to
equipment.
INSTRUCTION SHEET
Original Instructions
Solenoid Type Safety Switch
HS6E Series
S A F E T Y P R E C A U T I O N S
CAUTION
WARNING
* In order to verify if the product
you are interested in is certified
with the S mark, please check
the following section on our
website: "List of type numbers
certified with the S mark"
(Main circuit
・
Door monitor circuit)
Interlocking device Type
/the level of coded
Type 2 Interlocking device
/ low level coded actuator (EN ISO / ISO14119)
Resistive load
(AC-12)
Inductive load
(AC-15)
AC
Main
Circuit,
Look
monitor
circuit
30V
125V 250V
-
2A
-
-
1A
-
‹Ue, Ie›
Contact Ratings
Thermal Current ‹Ith›
Rated Insulation voltage ‹Ui›
Impulse withstand voltage ‹Uimp›
Altitude
Pollution degree
Operating Humidity
Condition
Operating Temperature
Applicable Directives
Standards for Use
Applicable Standards
0.5A (≥ 2 circuits)
1.0A (1 circuit)
35°C ≤ Operating temperature ≤ 50°C
1.0A (≥ 3 circuits)
2.5A (≤ 2 circuits)
-25°C ≤ Operating temperature < 35°C
30V(Between ground and LED,solenoid circuit)
300V(Door monitor circuit)
150V(Main,Lock monitor circuit)
0.5kV(Between ground and LED,solenoid circuit)
2 5kV(Door monitor circuit)
1 5kV(Main,Lock monitor circuit)
2,000m maximum
3(Inside 2)
45 to 85%RH(no condensation)
-25 to +50°C (no freezing)
Machinery Directive, Low Voltage Directive
IEC60204-1, EN60204-1
GS-ET-19, UL508, CSA C22.2 No.14
IEC60947-5-1, EN60947-5-1
EN ISO / ISO14119, GB14048.5
Fzh
=
maximum force (F1max.)
Safety coefficient (=1.3)
Rated Power Consumption
Illumination Color
Light Source
Turn OFF Voltage
Turn ON Voltage
Rated Current
Rated Operating Voltage
Resistive load
(DC-12)
Inductive load
(DC-13)
Resistive load
(AC-12)
Inductive load
(AC-15)
Resistive load
(DC-12)
Inductive load
(DC-13)
DC
AC
DC
Door
monitor
circuit
-
2A
0.4A
-
1A 0.22A
-
-
2.5A 1.5A
-
1.5A 0.75A
2.5A 1.1A 0.55A
2.3A 0.55A 0.27A
Approx. 2.7W
Green
LED
Rated voltage x 10% minimum (at 20°C)
Rated voltage x 85% maximum (at 20°C)
110 mA (solenoid 100mA, LED 10mA : initial value)
DC24V 100% duty cycle
Rated Operating Voltage
DC24V 100% duty cycle
Use 250V / 10A fast acting type fuse
*4
50A (250V)
NEMA Type12 (operating temp. -25 to 45°C)
IP67 (IEC60529)
300 m Ω maximum (initial value, 1m cable)
60 N minimum
8 mm minimum
24V AC/DC 0.1A Resistive Load)
(900 operations / hour,
1,000,000 operations minimum.
AC-12 125V 2A, DC-12 125V 0.4A)
(900 operations / hour,
100,000 operations minimum.
1,000,000 operations minimum. (GS-ET-19)
2,000,000 (EN ISO 13849-1 AnnexC Table C.1)
0.05 to 1.0 m/s
900 operations/hour
Class
II
(IEC61140) *1
Short-circuit Protective Device
Conditional short circuit current
Degree of Protection
Contact Resistance
Direct Opening Force
Direct Opening Travel
Actuator Tensile Strength
when Locked
Electrical Durability
Mechanical Durability
B10d
Operating Speed
Operating Frequency
Class of Protection
Shock Resistance
Vibration Resistance
Operating Extremes: 100m/s
2
, Damage Limits: 1,000m/s
2
Operating Extremes:10 to 55 Hz, half amplitude 0.35mm
Damage Limits: 30 Hz, half amplitude 1 5mm
Fzh=500N minimum
F1max.=650N minimum (GS-ET-19) *2, *3
(Fzh=100N minimum: HS9Z-A62 actuator)
Solenoid