HS5E-K Interlock Switches with Key
LD6A Series
SignaLight
XW Series
Emergency Stop
Switch
Maintenance Mode Change
HW Series
Key Selector Switch
(Pin Tumbler)
Mode Change
Door Unlocked (safety output OFF)
Hazards of the system and robot are isolated by the safety guard . When a worker needs to work inside the hazardous
area for maintenance, the worker stops the machine using the key to change modes (1), unlock the guard using the key,
then remove the key to bring inside the safety guard (2) . The worker can switch operation modes and unlock the safety
guard using a single key . Furthermore, when the key is taken inside the hazardous area, the guard cannot be locked and
the system cannot be turned on . This enables the worker to work safely in the hazardous area .
Door Handle Actuator
HS5E-K
Key Interlock
Switch
+
Door Handle
Actuator
Single
Key!
Head removal detection circuitry is employed in the HS5E-K . With this innovative function, the monitor circuit (41-42) turns off
when the head is removed from the switch, such as when removing the head to change the head direction (applicable with all
models of HS5E-K) .
With the head installed on the switch, monitor circuits 41-42 and 51-52 operate in synchronization while the key locks/unlocks
the actuator . When the head is removed, 41-42 turns off and 51-52 turns on . This disagreement is detected by the head removal
detection function .
Head Removal Detection Circuitry (patented)
Actuator unlocked
Actuator locked
Monitor circuit
(41-42) with
head removal
detection
function
Head removed
Actuator
unlocked
Actuator
locked
Head
removed
Monitor Circuit
(NC)
42
41
51
52
Monitor Circuit
(NC)
Brown
Pink
Brown/White
Pink/White
LOCK
UNLOCK
OFF
ON
OFF
ON
Note: Head removal detection function is not direct opening .
Actuator
unlocked
Actuator
locked
Head
removed
42
41
51
52
(–)
(+)
Monitor Circuit
(NC)
Monitor Circuit
(NC)
Brown
Pink
Brown/White
Pink/White
OFF
ON
ON
OFF
ON
ON
OFF
ON
Disag
reement