INSTALLATION
30 STANDARD PANEL BOARD
ELECTRICAL WIRING DIAGRAM FOR SINGLE PHASE BURNER AND PUMP
E
E
E
E
L1
T2
N
S3
T1
B4
IG
11
41
32
32
12
13
31
230V~ 50Hz
2
1
3
4
4-4
24
14
C
2
1
22
12
21
11
C
2
G-V
6-6
7-7
8-8
9-9
10-10
Ts
7
14 15 16
6
9
5
8
10
B
A
20
21
24
Pi
18
17
23
22
19
11
12
Ipi
Ib
(50°C)
(60°÷90°C)
(54°÷84°C)
(100°C)
Tm
Te1
F1 (max 4 A)
Te2
13
C
N
Ph
B5
T6
T7 T8
1 stage burner plug
st
2 stage burner plug (optional)
nd
Te1 1
st
stage working thermostat (60°C÷90°C)
Te2 2
nd
stage working thermostat (54°C÷84°C)
Tm Minimum thermostat (50°C)
Ts High limit thermostat (100°C)
Pi CH pump
A Burner lockout warning lamp (eventual)
Ph Phase (230V ~50Hz)
N Neutral
F1 General fuse (max 4A)
Ib Burner switch
IG Illuminated main switch
Ipi CH pump switch
B Hour meter for 1
st
stage operation
C Hour meter for 2
nd
stage operation
PANEL BOARD TYPE 24969 -
FUNCTIONS DESCRIPTION
Through the main switch 11 the panel
board and all the equipments connected
to it will be under power. The switches
12 & 13 switch On and OFF the
power to the burner and the Heating
pump (via a relay, if necessary).With the
thermostat 21 the working temperature
of the boiler can be adjusted. This
thermostat is provided with a DPDT
contact, for the control of a two stage
burner. The differential between the
switching points of the two double pole
is 6°C (not adjustable). The minimum
thermostat, accessible through the
opening of the panel board cover,
switches OFF the C.H. pump during the
reacing of the steady state and up to the
obtention of 50 °C within the boiler. On
the electrical supply line to the boiler a
switch with fuses is to be forseen.
24
40
22
21
31
33
32
34
41
11
18
14
15
16
17
30
12
13
23
25
26
van 5725
11. Boiler ON/OFF Switch
(illuminated)
Position I . . ON. Position . . OFF.
12.
Burner Switch
Position I . . ON. Position . . OFF.
13. Pump Switch
Position I I . . ON. Position . . OFF.
21.
Boiler ON/OFF, High/Low Thermostat
(High fire 54ºC - 84ºC, low fire 60ºC - 90ºC)
22. Boiler Safety Thermostat
(Set at 100ºC) with manual reset.
24. Minimum Thermostat
(Set at 50ºC) Controls the pump operation.
30. Thermometer
Indicator flow temperature.
41. Fuse
Rated at 4 amps.
INST
ALLA
TION