Optia FF
-
Installation & Servicing
GENERAL
Key to symbols
IE
= Ireland
GB
= United Kingdom
PMS
= Maximum operating pressure of water
C
12
& C
32
=
A room sealed appliance designed for
connection via ducts to a horizontal or vertical terminal,
which admits fresh air to the burner and discharges
the products of combustion to the outside through
orifices which, in this case, are concentric. The fan is
down stream of the combustion chamber.
C
72
= A room sealed appliance designed for connection via
concentric vertical ducts and a draught diverter located
in the roof space to a secondary flue. The combustion
air is taken from the roof space. The fan is down
stream of the combustion chamber.
I
2H
= An appliance designed for use on 2nd Family gas,
Group H only.
CAUTION.
To avoid the possibility of injury during the installation, servicing or cleaning of this
appliance, care should be taken when handling edges of sheet steel components.
Boiler Size
FF 30
FF 40
FF 50
FF 60
FF 70
FF 80
FF 100
Boiler input
kW
10.8
14.5
17.85
21.9
25.3
29.1
36.5
Btu/h x 1000
36.8
49.3
61.0
74.7
85.6
99.3
124.7
Gas consumption
l/s
0.275
0.375
0.458
0.567
0.652
0.755
0.947
ft
3
/h
35.4
47.5
58.7
72.0
83.3
95.6
120.7
Boiler output
kW
8.8
11.7
14.7
17.6
20.5
23.4
29.3
Btu/h x 1000
30
40
50
60
70
80
100
Burner Setting
pressure (HOT)
mbar (in.w.g.)
12.4 (5.0) 11.0 (4.4) 12.7(5.0) 13.7 (5.5) 12.1 (4.8) 12.9 (5.2) 14.0 (5.6)
Seasonal Efficiency (SEDBUK)*
(Band D)
[79.4]%
[78.7]%
[79.8]%
[78.2]%
[78.5]%
[78.2]%
[78.0]%
Boiler Size
FF 30
FF 40
FF 50
FF 60
FF 70
FF 80
FF 100
Gas supply connection
(in. BSP)
Rc 1/2 (1/2) 1/2" (BSP Female)
Flow connection
22mm
28mm copper
copper
(FEMALE)
Return connection
22mm
28mm copper
copper
(FEMALE)
Maximum static water head
m (ft.)
30.5 (100)
Minimum static water head
m (ft.)
0.45 (1.5)
Electrical supply
230 V 50 Hz Boiler power consumption; 100W
Fuse rating
External; 3A
Internal; F1A to BS.4265
Water content
litre (gal.)
2.7 (0.6)
3.65 (0.8)
4.65 (1.0)
4.65(1.0)
Dry Weight
kg (lb)
37.0 (81.6)
42.0 (92.6)
48.0 (105.8)
48.0(105.8)
Maximum installation weight
kg (lb)
30.0 (66.2)
34.0 (75.0)
40.0 (88.2)
40.0(88.2)
Boiler size
Height
mm (in.)
700 (27.5)
Width
mm (in.)
380 (15.0)
Depth
mm (in.)
300 (11.8)
Flue duct diameter
mm (in.)
100 (4.0)
Flue duct length (max)
m (ft)
3 (9.8)
0.6 (2)
Note.
Gas consumption is calculated using a calorific value of
38.7 MJ/m
3
(1038 Btu/ft
3
) gross or 34.9 MJ/m
3
(935 Btu/ft
3
) nett
To obtain the gas consumption at a different calorific value:-
a. FOR L/S
- divide the gross heat input (kW) by the gross C.V.
of the gas (MJ/m
3
)
b. FOR FT
3
/H
- divide the gross heat input (Btu/h) by the gross
C.V. of the gas (Btu/ft
3
)
Table 1 - General Data
Table 2 - Performance Data
*
The value is used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of
dwellings. The test data from which it has been calculated have been certified by a notified body.