7.4 CLEANING & CHANGE OIL (BY OPERATOR)
- Cleaning reminding
Motor pump running time (up and down) accumulates up to 300 minutes since new
machine be operated first time, the software will present a special displaying
(following) to remind user to do the filer clearing of the valves and hydraulic oil
changing.
LCD display 18
th
And also while the time reaches 3600 minutes, it will appear again.
To continue operation, just press ESC button twice.
-
Valve cleaning
(1) Lower the carriage to ground or rest it on lock (PARK)
(2) Turn off the control case switch and the battery switch.
(3) Take off the coil on the electro-magnetic valve.
(4) Take out the valve pin.
(5) Clean the filter / mesh with compressed air.
(6) Put back the valve pin and the coil.
7.5 CHANGE OIL
- Change the oil.
(1) Lower the lift completely to floor.
(2) Remove the oil from the tank.
(3) Refill with approximately 13.5 Liters of hydraulic oil meeting AW32 or 46,
filtrated to 4 Micrometer.
(4) Check the oil level in oil tanks on each column, add if necessary.