50 REMOVAL OF SUMP COVER
1.
Refer to Frame 42.
2.
Remove the jacket front and inner
front panels. (Refer to Frame 45).
3.
Remove the 6 nuts and withdraw the
sump cover plate taking care to retain
the gasket.
4.
Scrape out any deposits within the
sump.
5.
Re-assemble in reverse order
replacing the sump cover plate
gasket if it is showing signs of wear.
6.
Refer to Frame 42 for final safety
checks.
3
51 CLEANING CONDENSATE TRAP
1.
Refer to frame 42.
2.
Remove the jacket front, inner front, controls fascia, top
and left side panels. (Refer to Frame 45).
3.
Place a container beneath the condensate trap to
collect the condensate contained within.
4.
Remove bottom nut/plug from the condensate trap
whilst collecting the condensate which will drain out.
5.
Withdraw the cartridge and ball from within the
condensate trap. Thoroughly clean the cartridge and
ball by flushing with water.
6.
If deposits are visible in the condensate trap body, it
can be removed by unscrewing the inlet and outlet
nuts. Thoroughly flush the body with water.
7.
Re-assemble in reverse order, replacing the
condensate trap if there are signs of wear to any seals
or the ball.
8.
Refer to Frame 42 for final safety checks.