Exalt WHB & FSB
Natural Gas to Propane Conversion Instructions
Kit Part Number
•
EXRKIT08 (Heat Only 110)
•
EXRKIT10 (Heat Only/Combi 155)
•
EXRKIT12 (Heat Only/Combi 199)
Kit Includes
•
Rating Label
•
Conversion Label
•
(1) Propane Gas Venturi
•
Acoustic Foam (required for 110 and 155 models ONLY)
Recommended Tools
•
Adjustable Wrench / 10 mm Socket & Ratchet
•
Phillips Head Screwdriver
•
Flat Head Screwdriver
•
Calibrated Combustion Analyzer
Indicates a potentially hazardous situation
which, if ignored, can result in serious injury or
substantial property damage.
Indicates special instructions on installation, operation
or maintenance, which are important to equipment
but not related to personal injury hazards.
When converting the appliance from Natural Gas to Propane ensure that the conversion is completed before fully installing
the air inlet piping.
For your safety, turn off electrical power supply
at service panel and allow unit to cool before pro-
ceeding to avoid possible electrical shock and
scald hazard. Failure to do so can cause severe
personal injury or death.
Upon completion of the conversion from Natural to Pro-
pane, affix the new rating label included in the kit to the
unit adjacent to the existing rating label. DO NOT affix
the new label over the existing rating label. Add propane
conversion labelling to the gas valve.
Failure to follow instructions below can result in
severe personal injury or damage if ignored.
•
Instructions are for a qualified installer/
service technician only.
•
Read all instructions before proceeding.
•
Follow instructions in proper order.
These instructions cover NG to LP conversion for Exalt
boilers only. Each kit is supplied with one venturi.
227798 A02
Revision Date: 10/2021
2019-30 Exalt WHB & FSB Natural
Gas to Propane Conversion
Instructions
!