background image

10

ESPRIT 2 - 

User’s

5

QUICK REVIEW OF PROGRAMMED TIMES AND TEMPERATURES

DISPLAY SHOWS time / day

and backlight is OFF

DISPLAY SHOWS time / day

and backlight is ON

The left hand “Timed” is flashing, together

with the Radiator symbol and the word

“PROG” is showing

The left (or right) hand “Timed” is flashing,

together with the Radiator (or Tap) Symbol

is the PROG button

is the SELECT button

are the UP and DOWN buttons

Radiator (or Tap) symbol is steady.

The first ON time for Monday is shown

Monday’s first OFF time is shown

etc.......

The last OFF time for Sunday is shown

Return to “Monday”

S

P

P

P

S

Press ‘PROG’ button 

briefly

Press ‘PROG’ button 

and hold until . . .

o

C

” is flashing, together with the Tap

symbol

The Tap symbol is steady.

Temperature is displayed

Return to time / date display

S

S

*For systems with underfloor heating or other systems
requiring a maximum flow temperature different to 82

o

C, the

maximum radiator temperature can be set in a similar
manner to “Setting the HW Temperature”.

Note.
This section cannot be used to amend the settings,
see Frames 3 and 4.

Checking the Heating (or Hot Water) times

Checking the Hot Water Temperature *

206104-1.pmd

26/05/2010, 16:01

10

Summary of Contents for ESPRIT 2 24

Page 1: ...any part on this appliance use only spare parts that you can be assured conform to the safety and performance specification that we require Do not use reconditioned or copy parts that have not been cl...

Page 2: ...d combustion A 7 day programmer is built into the boiler capable of 3 timed periods per day Due to the high efficiency of the boiler condensate is produced from the flue gases and this is drained to a...

Page 3: ...n the heat exchanger does not drop below 4o C If external frost protection is required a kit can be purchased to support an external frost thermostat Boiler overheat thermostat This thermostat will sh...

Page 4: ...hey have contact your installer Boiler is not working for central heating or hot water but attempts to fire by going through 3 ignition attempts Display shows L F flashing Press select reset button C...

Page 5: ...MT BST ADJUSTMENT The clock can be easily adjusted between GMT and BST by pressing the UP button for 3 seconds NOTE The time is pre set before leaving the factory If on receipt of the boiler the time...

Page 6: ...flashing together with the radiator symbol The Radiator symbol is flashing together with o C The right hand Timed is flashing together with the Tap symbol The Tap symbol is flashing together with o C...

Page 7: ...becomes steady and the 12 24 hr symbol flashes The hours digits flash The hours digits become steady and the minutes digits flash The am or pm symbol flashes in 12 hr mode only The clock now displays...

Page 8: ...u have selected period 1 on the day s shown ON flashes and a time is showing The hours figure flashes The minutes figure flashes 12 hr mode only The am or pm symbol flashes Use Up and Down Buttons to...

Page 9: ...and DOWN buttons The Tap symbol is steady The temperature figure flashes Use Up and Down buttons to set value Hot water delivery temperature can be set from 40 to 65 o C Change accepted Display revert...

Page 10: ...Monday is shown Monday s first OFF time is shown etc The last OFF time for Sunday is shown Return to Monday S P P P S Press PROG button briefly Press PROG button and hold until o C is flashing togeth...

Page 11: ...Period 3 ON 17 00 Period 3 OFF 22 30 Radiator Temperature 82 o C Hot Water Temperature 60 o C 7 FAULT FINDING If the display shows a spanner symbol and the time or temperature indication is replaced...

Page 12: ...ay and backlight is OFF DISPLAY SHOWS time day and backlight is ON The left hand Timed is flashing together with the Radiator symbol and the word PROG is showing The left hand Timed is flashing togeth...

Page 13: ...ols relate to the times being programmed 1 2 and 3 are the daily periods ON and OFF are the functions DEL is used to clear a programmed period PROG is shown during program amendment ON OFF TIMED ADVAN...

Reviews: