ESPRIT 2 - 

User’s

z

This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been
given supervision or instructions concerning use of the
appliance by a person responsible for their safety.

z

Children should be supervised to ensure that they do not play
with the appliance.

In cases of repeated or continuous shutdown a Gas Safe
Registered Engineer or in IE a Registered Gas Installer (RGII)
should be called to investigate and rectify the condition causing
this and carry out an operational test. Only the manufacturers
original parts should be used for replacement.

M i n i m u m   C l e a r a n c e s

Clearances of 

165mm (6 1/2"

) above, 

100mm (4"

) below, 

5mm

(1/4"

) at the sides and 

450mm (17 3/4

") at the front of the boiler

casing must be allowed for servicing.

The minimum front and bottom clearance allowed when built into
a cupboard is 5mm.

To light the boiler. Refer to Frame 1

The boiler incorporates a factory fitted programmer, refer to page
5 onwards of these instructions for setting the programmer
before continuing.

1.

CHECK THAT THE ELECTRICITY SUPPLY TO THE BOILER IS OFF.

2.

Set the mains ON/OFF switch (A) to OFF.

3.

Ensure that all DHW taps are turned off.

4.

Switch ON the electricity supply to the boiler and check that the
room thermostat is set to call for heat.

5.

Set the mains ON/OFF switch to ON.

The boiler will commence the ignition sequence, first supplying
heat to pre-heat the domestic hot water and then to the central
heating, if required.

Note. 

In normal operation the itime programmer display (B) will

show the time of day.

Standby - no demand for heat.

  CH being supplied.

   DHW being supplied.

During normal running the flame symbol will remain illuminated.

Note.

If the boiler fails to light after 3 attempts the fault code “

LF

will be displayed.

Press the select button (C) for greater than 3 seconds then release.
The boiler will repeat the ignition sequence. If the boiler still fails to
light consult a Gas Safe Registered Engineer or in IE a Registered
Gas Installer (RGII).

Destination Countries: GB, IE

ESPRIT 2

(Natural Gas Only)

24 

...........

 G.C. Appliance No.  47-348-71

30 

...........

 G.C. Appliance No.  47-348-72

35 

...........

 G.C. Appliance No.  47-348-73

I n t r o d u c t i o n

The 

ESPRIT 2 

is a wall mounted, room sealed, condensing

combination boiler providing both central heating and
instantaneous domestic hot water.  Featuring full sequence
automatic spark ignition and fan assisted combustion.

A 7 day programmer is built into the boiler capable of 3 timed
periods per day.

Due to the high efficiency of the boiler, condensate is produced
from the flue gases and this is drained to a suitable disposal
point through the plastic waste pipe at the lower rear of the
boiler.  A condensate 'plume' will also be visible at the flue
terminal.

S a f e t y

Current Gas Safety (Installation & Use)
Regulations or rules in force.

In your own interest, and that of safety, it is the law that this
boiler must be installed by a Gas Safe Registered Engineer, in
accordance with the above regulations.

In IE, the installation must be carried out by a Registered Gas
Installer (RGII) and installed in accordance with the current
edition of I.S. 813 “Domestic Gas Installations”, the current
Building Regulations and reference should be made to the
current ETCI rules for electrical installation.

It is essential that the instructions in this booklet are strictly
followed, for safe and economical operation of the boiler.

E l e c t r i c i t y   S u p p l y

This appliance must be earthed.

Supply: 230 V ~ 50 Hz. The fusing should be 3A.

Connection must be made in a way that allows complete
isolation of the electrical supply such as a double-pole switch,
having a 3mm (1/8") contact separation in both poles, serving
only the boiler and system controls. Alternatively, a 3-pin
UNSWITCHED socket may be used.  The means of isolation
must be accessible to the user after installation.

Important Notes

z

This appliance must not be operated without the casing
correctly fitted and forming an adequate seal.

z

If the boiler is installed in a compartment then the
compartment MUST NOT be used for storage purposes.

z

If it is known or suspected that a fault exists on the boiler
then it MUST NOT BE USED until the fault has been
corrected by a Gas Safe Registered Engineer or in IE a
Registered Gas Installer (RGII).

z

Under NO circumstances should any of the sealed components
on this appliance be used incorrectly or tampered with.

All Gas Safe Registered Engineers carry a Gas Safe Register ID card, and have a registration number. Both should be recorded
in the 

Benchmark 

Commissioning Checklist.  You can check your installer by calling Gas Safe Register direct on 0800 4085500

THE BENCHMARK SERVICE INTERVAL RECORD MUST BE COMPLETED AFTER EACH SERVICE

Ideal Stelrad Group

 is a member of the Benchmark scheme and fully supports the aims of

the programme.  Benchmark has been introduced to improve the standards of installation and
commissioning of central heating systems in the UK and to encourage the regular servicing of
all central heating systems to ensure safety and efficiency.

206104-1.pmd

26/05/2010, 16:01

2

Summary of Contents for ESPRIT 2 24

Page 1: ...any part on this appliance use only spare parts that you can be assured conform to the safety and performance specification that we require Do not use reconditioned or copy parts that have not been cl...

Page 2: ...d combustion A 7 day programmer is built into the boiler capable of 3 timed periods per day Due to the high efficiency of the boiler condensate is produced from the flue gases and this is drained to a...

Page 3: ...n the heat exchanger does not drop below 4o C If external frost protection is required a kit can be purchased to support an external frost thermostat Boiler overheat thermostat This thermostat will sh...

Page 4: ...hey have contact your installer Boiler is not working for central heating or hot water but attempts to fire by going through 3 ignition attempts Display shows L F flashing Press select reset button C...

Page 5: ...MT BST ADJUSTMENT The clock can be easily adjusted between GMT and BST by pressing the UP button for 3 seconds NOTE The time is pre set before leaving the factory If on receipt of the boiler the time...

Page 6: ...flashing together with the radiator symbol The Radiator symbol is flashing together with o C The right hand Timed is flashing together with the Tap symbol The Tap symbol is flashing together with o C...

Page 7: ...becomes steady and the 12 24 hr symbol flashes The hours digits flash The hours digits become steady and the minutes digits flash The am or pm symbol flashes in 12 hr mode only The clock now displays...

Page 8: ...u have selected period 1 on the day s shown ON flashes and a time is showing The hours figure flashes The minutes figure flashes 12 hr mode only The am or pm symbol flashes Use Up and Down Buttons to...

Page 9: ...and DOWN buttons The Tap symbol is steady The temperature figure flashes Use Up and Down buttons to set value Hot water delivery temperature can be set from 40 to 65 o C Change accepted Display revert...

Page 10: ...Monday is shown Monday s first OFF time is shown etc The last OFF time for Sunday is shown Return to Monday S P P P S Press PROG button briefly Press PROG button and hold until o C is flashing togeth...

Page 11: ...Period 3 ON 17 00 Period 3 OFF 22 30 Radiator Temperature 82 o C Hot Water Temperature 60 o C 7 FAULT FINDING If the display shows a spanner symbol and the time or temperature indication is replaced...

Page 12: ...ay and backlight is OFF DISPLAY SHOWS time day and backlight is ON The left hand Timed is flashing together with the Radiator symbol and the word PROG is showing The left hand Timed is flashing togeth...

Page 13: ...ols relate to the times being programmed 1 2 and 3 are the daily periods ON and OFF are the functions DEL is used to clear a programmed period PROG is shown during program amendment ON OFF TIMED ADVAN...

Reviews: