Classic
SE FF
-
Installation & Servicing
5
GENERAL
CONTENTS
Air Supply
. .....................................................................
8
Benchmark Commissioning Checklist
.....................
42
Boiler Clearances
.........................................................
7
Boiler Exploded View
.................................................
13
Burner Exploded View
............................................... .
40
Control Box Exploded
View
...................................... .
40
Electrical Connections
...............................................
24
Electrical Regulations
..................................................
9
Extension Ducts - Fitting
............................................
22
External Controls
........................................................
24
Fault Finding
................................................................
37
Flue Installation
.............................................................
8
Rear installation
......................................................
16
Side installation
.......................................................
19
Gas Safety
.....................................................................
6
Gas Supply
....................................................................
8
Initial Lighting
. ............................................................
27
Installation
..................................................................
13
Mandatory Requirements
............................................
6
Pump
...........................................................................
10
Safe Handling
................................................................
6
Servicing
.....................................................................
29
Short List of Parts
......................................................
38
Spares Replacement
.................................................
31
System Electrical Diagrams
......................................
25
Terminal Guards
. ..........................................................
8
Water and Systems
.....................................................
9
Water Treatment
..........................................................
9
Classic SE FF
Data Badge:
on top of the controls support
B.G. Certified - P.I. No. 87AP107
Destination Countries: GB & IE
Models
G.C. Appliance No.
White
Silver
Classic SE9 FF ............ 41 395 30 ....... 41-397-63
Classic SE12 FF ......... 41 395 31 ....... 41-397-64
Classic SE15 FF ......... 41 395 32 ....... 41-397-65
Classic SE18 FF ......... 41 395 33 ....... 41-397-68
Classic SE21 FF ......... 41 395 34 ....... 41-397-69
Classic SE24 FF ......... 41 395 35 ....... 41-397-70
Classic SE30 FF ......... 41 395 36 ....... 41-397-71
Natural Gas only
Appliance Type
Boiler size
C
12
All Models
C
32
All Models except SE30 FF
C
72
SE18 FF & SE24 FF only
B
oiler
Page
Make and model ....................................................... 5
Appliance serial no. on data badge ....................... 13
SEDBUK No. % ......................................................... 4
Controls
Time and temperature control to heating ......... 25/26
Time and temperature control to hot water ...... 25/26
Heating zone valves .......................................... 25/26
TRV's ......................................................................... 9
Auto bypass ............................................................... 9
Boiler interlock .......................................................... 9
For all boilers
Flushing to BS.7593 ................................................. 9
Inhibitor ...................................................................... 9
Central heating mode
Heat input ................................................. to be calculated
For assistance see Technical Helpline on the back page
Page
Burner operating pressure ....... measure and record
Central heating flow temp. ........ measure and record
Central heating return temp. ..... measure and record
For combination boilers only
Scale reducer ......................................................... n/a
Hot water mode
Heat input ............................................................... n/a
Max. operating burner pressure ............................ n/a
Max. operating water pressure .............................. n/a
Cold water inlet temp ............................................. n/a
Hot water outlet temp. ............................................ n/a
Water flow rate at max. setting ............................... n/a
For condensing boilers only
Condensate drain .................................................. n/a
For all boilers:
complete, sign & hand over to customer
For GB, to comply with Building Regulations Part L1 (Part J in Scotland) the boiler should be fitted in accordance with the
manufacturer's instructions. Self-certification that the boiler has been installed to comply with Building Regulations can be
demonstrated by completing and signing the Benchmark Commissioning Checklist.
BENCHMARK COMMISSIONING CHECKLIST
NOTE TO THE INSTALLER: COMPLETE
THE BENCHMARK COMMISSIONING
CHECKLIST AND LEAVE THESE
INSTRUCTIONS WITH APPLIANCE
200544-5.pmd
20/02/2008, 13:26
5