Classic SE
FF
-
Installation & Servicing
21
INSTALLATION
SIDE FLUE OUTLET
1.
The boiler is supplied for rear
outlet installation. Remove
the blanking plate from the
direction required and use
this to blank off the rear outlet.
2.
Lift the boiler onto the wall
mounting plate hooks as
shown.
Do not use the burner/
controls for lifting.
3.
Fit the M8 screw, washer and
rectangular plate to retain the
boiler.
Note.
Before fully tightening the
M8 screw check the boiler
alignment using a spirit level and
adjust as necessary with the
jacking screw.
29 WALL MOUNTING PLATE
1.
Fix the mounting plate to the wall with the No.14 x 50mm
wood screws.
2.
If downward routing of pipes is required then the
downward routing pipe brackets and M8 spacer
(supplied in the Downward Piping Kit) should be fitted to
the wall mounting plate now.
3.
Fit the bottom 2 screws to secure the bracket(s) to the
wall, through the wall mounting plate.
4.
Check with a spirit level that the plate is vertical.
Notes
1.
Have ready to hand the M8 screw, washer and rectangular plate supplied in the hardware pack.
2.
For downward routing of pipes the M5 spacer (supplied in the Downward Piping Kit) should now be
fitted to the back of the boiler.
28 FITTING THE SIDE OUTLET PLATES
30 MOUNTING THE BOILER
Note.
If the boiler is fitted closer than 25mm to the side wall
the side outlet plate must be fitted now.
1.
Split the side outlet plate into 2 down the split line.
2.
Fit the 2 halves of the side outlet plate to the wall,
ensuring they are behind the boiler sealing ring.
200544-5.pmd
20/02/2008, 13:26
21