These appliances are designed for use with Natural
Gas only. They have been tested and conform with
the provisions of BS. 6332 and BS. 5258.
CERTIFIED PRODUCT
Manufactured under a BS EN ISO 9001:
1994 Quality System accepted by BSI
CARADON IDEAL Ltd.
pursues a policy of continuing
improvement in the design and performance of its
products. The right is therefore reserved to vary
specification without notice.
CARADON IDEAL Ltd
,
P.O. Box 103, National Avenue,
Kingston upon Hull, HU5 4JN.
Telephone: 01482 492 251
Fax: 01482 448 858.
Registration No. London 322 137.
Registered Office; National Avenue,
Kingston upon Hull, HU5 4JN.
A subsidiary of Caradon p.l.c
Printed in England
Please use the following numbers for speedy assistance.
Ideal Parts
.... ...............................
Tel: 01482 498 665
................................................... Fax: 01482 498 489
Customer Care & Technical Support
.
Scotland/N. England/Midlands ..... Tel: 01482 498 636
Southern England/S. Wales ......... Tel: 01482 498 660
................................................... Fax: 01482 498 666
Publications/literature
. ..............
Tel: 01482 498 467
Customer Care & Technical Support
FROST PRECAUTIONS
Leave the boiler running at a reduced setting when the
premises are to be unoccupied for short periods.
For longer periods the entire system, including the domestic
water supply, should be drained down.
If the system includes a frost thermostat, in cold weather
the boiler should be turned OFF at the time overriding switch
only.
All other switches, including the mains supply and the boiler
thermostat, should be left in the normal running position.
TTB DOWNDRAUGHT THERMOSTAT
(CF only)
This appliance is fitted with a TTB downdraught thermostat
for added safety and protection. If this thermostat should
operate and switch off the appliance it is because the flue is
subject to downdraught, probably as a result of adverse wind
conditions.
The TTB is an automatic reset thermostat which will reset
once wind conditions have returned to normal, subject to a
built-in reset delay of between 10-25 minutes.
The TTB is an IMPORTANT SAFETY DEVICE and MUST
NOT be put out of action or interfered with in any way.
In cases of repeated or continuous shutdown a CORGI
registered person should be called to investigate and rectify
the condition causing this. Only the manufacturer's original
parts should be used for replacement.
TO RELIGHT THE BOILER
Repeat the procedure detailed in paragraphs 1-5 in 'To Light
the Boiler'.
If required, the pilot burner may be ignited by means of a
spill inserted though the sight glass opening (D).
ESCAPE OF GAS
Should a gas leak or fault be suspected contact your gas
supplier
without delay.
Do not search for gas leaks with a naked flame
CLEANING
For normal cleaning simply dust with a dry cloth.
To remove stubborn marks and stains wipe with a damp
cloth and finish off with a dry cloth.
Do not use abrasive cleaning materials.
MAINTENANCE
The appliance should be serviced at least once a year by a
CORGI registered installer.
Note.
The appliance model is given on the data plate, located
on the front of the boiler base plate, behind the grille
assembly.