These appliances are designed for use with Natural
Gas only. They have been tested and conform with
the provisions of BS. 6332 and BS. 5258.

CERTIFIED PRODUCT
Manufactured under a BS EN ISO 9001:
1994 Quality System accepted by BSI

CARADON IDEAL Ltd.

 pursues a policy of continuing

improvement in the design and performance of its
products. The right is therefore reserved to vary
specification without notice.

CARADON IDEAL Ltd

,

P.O. Box 103, National Avenue,

Kingston upon Hull, HU5 4JN.

Telephone:  01482 492 251

Fax: 01482 448 858.

Registration No. London 322 137.

Registered Office;  National Avenue,

Kingston upon Hull, HU5 4JN.

A subsidiary of Caradon p.l.c

Printed in England

Please use the following numbers for speedy assistance.

Ideal Parts

.... ...............................

Tel: 01482 498 665

................................................... Fax: 01482 498 489

Customer Care & Technical Support

.

Scotland/N. England/Midlands ..... Tel: 01482 498 636
Southern England/S. Wales ......... Tel: 01482 498 660

................................................... Fax: 01482 498 666

Publications/literature

. ..............

Tel: 01482 498 467

Customer Care & Technical Support

FROST PRECAUTIONS

Leave the boiler running at a reduced setting when the
premises are to be unoccupied for short periods.

For longer periods the entire system, including the domestic
water supply, should be drained down.

If the system includes a frost thermostat, in cold weather
the boiler should be turned OFF at the time overriding switch
only.

All other switches, including the mains supply and the boiler
thermostat, should be left in the normal running position.

TTB DOWNDRAUGHT THERMOSTAT 

(CF only)

This appliance is fitted with a TTB downdraught thermostat
for added safety and protection. If this thermostat should
operate and switch off the appliance it is because the flue is
subject to downdraught, probably as a result of adverse wind
conditions.

The TTB is an automatic reset thermostat which will reset
once wind conditions have returned to normal, subject to a
built-in reset delay of between 10-25 minutes.

The TTB is an IMPORTANT SAFETY DEVICE and MUST
NOT be put out of action or interfered with in any way.

In cases of repeated or continuous shutdown a CORGI
registered person should be called to investigate and rectify
the condition causing this.  Only the manufacturer's original
parts should be used for replacement.

TO RELIGHT THE BOILER

Repeat the procedure detailed in paragraphs 1-5 in 'To Light
the Boiler'.

If required, the pilot burner may be ignited by means of a
spill inserted though the sight glass opening (D).

ESCAPE OF GAS

Should a gas leak or fault be suspected contact your gas
supplier 

without delay.

Do not search for gas leaks with a naked flame

CLEANING

For normal cleaning simply dust with a dry cloth.

To remove stubborn marks and stains wipe with a damp
cloth and finish off with a dry cloth.

Do not use abrasive cleaning materials.

MAINTENANCE

The appliance should be serviced at least once a year by a
CORGI registered installer.

Note.

 

The appliance model is given on the data plate, located

on the front of the boiler base plate, behind the grille
assembly.

Summary of Contents for 40

Page 1: ...limline 2 RS 40 41 349 39 Slimline 2 RS 50 41 349 40 Slimline 2 CF 40 41 349 37 Slimline 2 CF 50 41 349 38 Natural gas models only Caution To avoid the possibility of injury during the operation or cleaning of this appliance care should be taken when handling the edges of sheet steel components ...

Page 2: ... compartment MUST NOT be used for storage purposes b The ventilation provided for the boiler during installation MUST NOT be blocked and a check should be made periodically that the ventilation areas are free from any obstruction c If it is known or suspected that a fault exists on the boiler then it MUST NOT be used until the fault has been corrected by a CORGI registered installer d Flammable ma...

Page 3: ...ss the control knob C for a further 20 seconds 4 Should the pilot go out at this or any other stage turn the gas control knob C clockwise and release it Wait for 3 minutes Repeat instruction 3 but wait longer than 20 seconds before releasing the gas control knob C 5 Check that the electricity supply and all external controls are ON 6 Turn the boiler thermostat knob A to position 6 and the boiler w...

Page 4: ...uding the mains supply and the boiler thermostat should be left in the normal running position TTB DOWNDRAUGHT THERMOSTAT CF only This appliance is fitted with a TTB downdraught thermostat for added safety and protection If this thermostat should operate and switch off the appliance it is because the flue is subject to downdraught probably as a result of adverse wind conditions The TTB is an autom...

Reviews: