THE GAS SAFETY (INSTALLATION AND
USE) REGULATIONS 1994 & AMENDMENTS
1996.
It is law that all gas appliances are installed by a CORGI
registered installer [identified by
] in accordance with the
above regulations. Failure to install appliances correctly
could lead to prosecution. It is in your own interest, and that
of safety, to ensure that the law is complied with.
It is ESSENTIAL that the instructions in this booklet
are strictly followed, for safe and economic
operation of the boiler.
ELECTRICITY SUPPLY
This appliance must be efficiently earthed.
Supply: 230 V ~ 50 Hz
This appliance must be connected to the supply via a double-
pole switch, fused at 3A, having a 3mm [
1/8
"] separation in
both poles, serving only the boiler and system controls.
IMPORTANT NOTES
a.
If the boiler is installed in a compartment then the
compartment MUST NOT be used for storage purposes.
b.
The ventilation provided for the boiler during installation
MUST NOT be blocked, and a check should be made
periodically that the ventilation areas are free from any
obstruction.
c.
If it is known or suspected that a fault exists on the boiler
then it MUST NOT be used until the fault has been
corrected by a CORGI registered installer.
d.
Flammable materials MUST NOT be placed in close
proximity to the appliance. Materials giving off flammable
vapours MUST NOT be stored in the same room as the
appliance.
e.
Under no circumstances should any of the sealed
components on this appliance be used incorrectly or
tampered with.
1 BOILER CLEARANCES
Dimensions in mm (in.)
Boiler
Minimum
Minimum
A
or
B
A + B
CF 40
25
(1")
100
(4")
CF 50
25
(1")
100
(4")
RS 40
5 (
3/16
")
10 (
3/8
")
RS 50
5 (
3/16
")
10 (
3/8
")
MINIMUM CLEARANCES
A clearance of 535mm [21"] MUST be available at the
front of the boiler for servicing.
The minimum clearances given in Frame 1 MUST be
complied with, in order to maintain the safe running of the
boiler.