background image

Ideal Standard International NV

Corporate Village - Gent Building

Da Vincilaan 2

1935 Zaventem

Belgium

www.idealstandardinternational.com

1121 / A 868 898 40

Made in Germany

CUSTOMER CARE HELP LINE

0870 129 6085

CUSTOMER CARE FAX

01482 499611

E-MAIL

[email protected]

Ideal Standard (UK) Ltd
Ideal Standard,

The Bathroom Works, National Avenue

Kingston-upon-Hull, HU 4HS, England

23  INLINE SERVICE VALVES

 

 

When cleaning chromed products use only a mild detergent, rinse & wipe dry with  

 

 

a soft cloth. Ideally clean after each use to maintain appearance.

 

 

Never use abrasive, scouring powders or scrapers. Never use cleaning agents

 

 

containing alcohol, ammonia, hydrochloric acid, sulphuric acid, nitric acid,

phosphoric acid or organic solvents. Use of incorrect cleaning products / methods may result in chrome 

damage which is not covered by the manufacturer’s guarantee.

24  CLEANING CHROME SURFACES

Inline service valves 

(not supplied with this product)

 MUST be fitted to permit future maintenance of 

the cartridges. They also facilitate the cold water isolation test.

These should be fitted as close as is practicable to the water supply inlets of the thermostatic shower 

valve. Service valves should be installed in an easily accessible location.

Basic valve with isolating 

only feature is available un-

der spares code 

S9005AA.

15mm compression fittings 

at both ends & plated finish.

E960086NU.

 Brass valve 

with isolating & filter only 

features. 15mm com-

pression fittings at both 

ends. Supplied in pairs.

Spares code 

E960613NU

 contains 

a pair of combined service valves. 

Include a flow regulator, check valve, 

strainer mesh (filter) & isolating 

valve. The flow regulator and check 

valve can be removed if not required.

Ideal Standard pursues a policy of continuing improvements 

in design & performance of its products. This right is there-

fore reserved to vary specification without notice. Partial 

or total reproduction or copying of this manual without our 

permission is prohibited. Every effort has been made to en

-

sure the accuracy of its contents. However, if you discover 

any errors, please contact us. The manufacturer shall not be 

held liable for consequences arising from use of the product. 

The drawings & diagrams contained in this manual are to be 

considered approximate & are provided for information only.

For more information about our products & spares 

visit our website: www.idealstandard.co.uk

Summary of Contents for Ceratherm C100 A7537AA

Page 1: ...c Bar Shower Mixer supplied over head shower handset kit Ceratherm C100 Exposed Thermostatic Bar Shower Mixers INSTALLER After installation please pass this instruction booklet to user IMPORTANT BEFOR...

Page 2: ...ISSIONING PERIODIC CHECKS 18 11 FREQUENCY OF REGULAR SERVICING 18 12 COLD WATER ISOLATION CWI TEST 19 13 MAINTENANCE NOTES 19 14 DISASSEMBLY SEQUENCE OF MAINTENANCE 20 15 DEMOUNTING THE MIXER FOR DISI...

Page 3: ...5 G 1 2 65 300 1122 min 700 79 5 74 381 5 23 30 x 15 50 2 L 1750 180 58 3 Basic shower valve dimensions shown with mounting brackets assembled Shower kit overhead shower supplied with A7543AA 600 Show...

Page 4: ...square overhead shower plate 1750 shower hose slim shower hand set A7543AA Shower valve without mounting brackets A7537AA 600 Shower kit includes 600 riser rail a pair of mounting brackets sliding br...

Page 5: ...d as the vertical distance between the bottom of the cold water storage tank which feeds the hot water system and the highest point on the shower spray plate When installing with a shower pump the use...

Page 6: ...ervice valves for isolating both water supplies MUST be fitted below the bath to permit future maintenance of this product see sect 23 These should be fitted as close as practicable to the water suppl...

Page 7: ...ted zone of backflow risk for restrained hose which is longer than system design hose not permitted zone of backflow risk for unrestrained hose zone of backflow risk for restrained hose w c spill over...

Page 8: ...lose as practicable to the water supply inlets of the mixer in an easily accessible location NOTE service valves are not supplied with thiese products see section 23 Shower Kit Each product is supplie...

Page 9: ...ply pipes should be run within the wall cavity Hot supply pipe should be on the left hand side and the cold on the right Ensure that the hot and cold pipes are positioned 150mm apart and are level Use...

Page 10: ...aging conce aled pipework 10 MIN 20 MAX With the wall brackets in position the supply pipes should be trimmed as shown The pipes should project from the front face of the brackets by bet ween 10 to 20...

Page 11: ...ternate to ensure mixer remains parallel to the wall O rings can be wetted with water to help them slide Fit the O rings provided into the grooves of the escutcheon Tighten the coupling nuts as far as...

Page 12: ...tighten the two grub screws visible from the rear of the wall bracket This will secure the wall bracket to the riser rail 3 This assembly of the shower rail parts together can now be located onto the...

Page 13: ...centrally within the square orientate it as shown Mark the two slot positions on the wall 7 Drill two 6mm holes into the wall at the centre of the marked slots 8 Tap two wall plugs into the two drille...

Page 14: ...hower handset The flexible shower hose has integral seals at both ends The shower handset can be parked in the bracket using the conical portion of the shower hose as shown The shower parking bracket...

Page 15: ...t 2 Tap a wall plug into the 6mm drilled hole 3 Using a posi screw driver the screw pro vided securely fix the bracket to the wall 5 Example of a completed installation 4a Ensure the shower hose is tr...

Page 16: ...ition Rotating this handle downwards from the parked position commences water flow By rotating the handle 90 from the off position the user will encounter economy flow stop delivering about 50 of the...

Page 17: ...e further to the maximum flow stop Rotating this handle upwards from the parked position commences water flow will direct water to the top outlet This will activate the large overhead shower plate At...

Page 18: ...low 45 C If there is no significant change to the set outlet temperature 2 C or less change from the original settings and the fail safe shut off is functioning then the valve is working correctly and...

Page 19: ...clean all filters ensure check valves are working and make sure all isolating valves are fully open Refit the shower handset to the flexible hose upon completion of the test NOTE In order to isolate t...

Page 20: ...Use inline service valves if fitted 2 Fully open the flow or diverter handle to confirm water is switched off Unscrew the shower hose from the underside of the mixer This will permit some of the trap...

Page 21: ...ely dependent upon the water quality and service life As a minimum we recommend removal both handles thermostatic cartridge flow control or diverter cartridge Cleaning the cartridge strainer screens i...

Page 22: ...h 4 The drive bush can be removed if necessary by undoing the Phillips screw shown using a suitable screw driver 5 If necessary the square end caps fitted at each end of the mixer body can be removed...

Page 23: ...bore ensure the lug on the cartidge is orientated into the cut out in the mixer s bore as illustration above 6 Make sure the marking on the spline of the cartridge spindle is aligned with the edge of...

Page 24: ...9 Reverse the sequence to refit the drive bush handle Align the button edge of the handle to the rear edge of the mixer body overhead shower fully open fit screw roatate handle 90 back to the off posi...

Page 25: ...cap can remain inside the mixer body 2 Slide off the stop ring 3 Using a 17mm spanner or socket undo the flow cartridge The cartridge should now slide out of the mixer s bore 4 If necessary replace t...

Page 26: ...NU 1 Set 6 Non return valve A 861 372 NU 1 Set 7 Shower bracket cpl A 861 548 AA 2 Set 8 Shower hose 1750 mm A 4109 AA 1 pcs 9 Handspray 3Func 110 B 2232 AA 1 pcs 10 Slider holder f handshr B 961 024...

Page 27: ...7 Shower bracket cpl A 861 548 AA 2 Set 8 Connection nipple cpl A 861 550 NU 1 Set 5 1 2 1 3 4 9 15 10 13 11 12 14 8 9 7 6 A7543AA Ceratherm C100 Exposed Thermostatic Bar Shower Mixer supplied over h...

Page 28: ...se as is practicable to the water supply inlets of the thermostatic shower valve Service valves should be installed in an easily accessible location Basic valve with isolating only feature is availabl...

Reviews: