Ideal Security SK662 Manual Download Page 8

can wait for it to call you again and then enter the correct code. If your dialing sequence is set to one cycle and you have set up 

the auto-dialer to answer before your answering machine (if you have one connected) then you can call into the auto-dialer and 

enter in your codes again. If you made the initial call to the dialer you just have to redial and then enter the codes again.

5. VIEW STORED INFORMATION FUNCTION
Triggered Events History
The last 5 triggered Events, including the time the event occurred and the zone that was triggered are stored in memory.
To view triggered events: 
•  In standby mode, press #/DOWN  button
•  The time and zone of the first recorded triggered event will be displayed on the LED screen.
•  Pressing the  #/DOWN button repeatedly will cycle through 5 stored events ending with the most recent.
Stored Telephone Numbers
In standby mode, press */UP to view stored telephone numbers.
NOTE: If no buttons are pressed for 20 seconds, the auto-dialer will automatically exit view mode.

7. AUTO-DIALER BATTERY LOW LED INDICATOR
When the Battery Low LED flashes once every 1.5 seconds, it indicates that the battery power in auto-dialer is running low. 

Replace the batteries immediately. If batteries are low, a false signal may be triggered and the auto-dialer may start dialing. 

Batteries in all units should be replaced at least once a year. 

LINK WIRELESS SENSORS TO THE AUTO-DIALER

 

The Water Detector included in this package has been factory linked to the auto-dialer (ZONE 1.). You may link additional 

sensors, remote controls or sirens to your auto-dialer. In certain circumstances you may have to re-link existing parts.
Make sure to test the reception range of all sensors before permanently mounting them. The approximate range for sensors 

is 60 meters (200′). Walls and other obstructions may interfere with reception.
You can link a total of 16 sensors and 8 remote controls to the auto-dialer .  

The system has a total of 10 zones for wireless sensors and remote controls:
•  Zone 1-8: link one wireless sensor per zone, they will trigger the auto-dialer in armed mode only. 
•  Zone 9: Learn up to 8 wireless sensors and they will trigger the auto-dialer in armed mode only.
•  REMOTE Zone  (LCD icon REMOTE) is the remote control zone, you can link up to 8 remote controls..
NOTE: If you wish to change the factory programed zone location of the Water Detector it must be deleted from its current    

 

zone and re linked to a new zone (see instructions below)

LINKING ADDITIONAL WIRELESS SENSORS OR REMOTE CONTROLS TO THE AUTO-DIALER
•  Enter your password and press the PROG button three (3) times. 
•  The “LEARN” icon will flash on the screen. 
•  Press ARM/DISARM to confirm, the system will go into learning ID code mode and zone 1 icon will flash. 
•  Press the */UP and #/DOWN buttons to select the zone you wish to learn your sensor to. When the screen flashes NO ID 

CODE, that means that zone is empty and you can link a sensor. If the screen flashes FULL then you already have a  

sensor linked to that zone. You can either choose another zone or press DEL./PAUSE to delete the sensor in that zone 

and link the new sensor. Remote controls must be linked to the REMOTE zone.

•  Press ARM/DISARM to confirm that this is the zone you want the sensor to be linked with
•  Trigger the sensor or remote control that you are linking. For the wireless water alarm put the sensor in water to trigger. 

For other sensors see the instructions included with the sensor 

NOTE: If you have linked a motion detector to your auto-dialer, cover the lens of the motion sensor (place a towel over the 

sensor) before linking other items as the motion sensor will send a signal to auto- dialer every time you move.

•  You will hear a long beep from the auto-dialer to confirm that linking was successful and the screen will display FULL for 

zones 1-8.  Zone 9 will display the number of sensors in the zone up to a maximum of 8. The Remote zone will display the 

number of remote controls in the zone up to a maximum of 8.

•  Press the PROG button seven (7) times to exit the setup mode.

Summary of Contents for SK662

Page 1: ...d line and an electrical outlet and set to ARM mode it will alert you if water is detected The auto dialer will activate the built in siren or chime if set and dial out if set to up to 5 pre programme...

Page 2: ...install the system where it will be exposed to direct sunlight or rain 2 The built in siren is very loud never put the system close to your ear 3 The system should be installed away from heat sources...

Page 3: ...Zone 9 Can link up to 8 wireless sensors REMOTE zone Can link up to 8 remote controls Records the five most recent triggered alarms Built in flash memory to protect system data during a power failure...

Page 4: ...s and learned sensors 2 RECORD PERSONALIZED NOTIFICATION MESSAGE You can record a single personalized 20 second message that will be played back when you receive telephone notification that your syste...

Page 5: ...hold DEL PAUSE for 2 seconds until the letter F appears on the screen then enter 230 Press ARM DISARM button to confirm Press PROG button eight 8 times to exit set up mode 7 TO TURN THE AUTO DIAL FUNC...

Page 6: ...o 0 5 10 15 or 20 seconds Enter password followed by PROG button eight 8 times ENTRY will flash on the auto dialer screen Press the ARM DISARM button to confirm Using the UP and DOWN buttons select th...

Page 7: ...ITOR Enter 1 and after the beep you will be able to listen into the room where the auto dialer is installed After 30 seconds you will hear a beep to remind you that if you do not enter another code wi...

Page 8: ...The system has a total of 10 zones for wireless sensors and remote controls Zone 1 8 link one wireless sensor per zone they will trigger the auto dialer in armed mode only Zone 9 Learn up to 8 wireles...

Page 9: ...condition If The water sensor sends no signals when wet make sure that the metal contacts on the sensor are not corroded Gently scrape the contacts with a sharp knife to expose clean metal Contacts Ca...

Page 10: ...se check for updated instructions at www idealinc com WARRANTY 1 year limited warranty excluding batteries on components COMPATIBLE PRODUCTS Build a complete security system by adding additional senso...

Page 11: ...ligne de t l phone et une prise lectrique R glez l appeleur automatique sur le mode ARM Lorsque la pr sence d eau est d tect e l appeleur automatique d clenche la sir ne int gr e optionnelle et compos...

Page 12: ...vec appeleur automatique NOTEZ Pour modifier les param tres par d faut et tendre le syst me suivez les instructions d taill es fournies dans ce manuel CONSEILS DE S CURIT IMPORTANTS 1 N installez pas...

Page 13: ...fil Pour la zone REMOTE vous pouvez jumeler jusqu 8 d tecteurs sans fil Enregistrement des cinq derni res alarmes d clench es M moire Flash int gr e pour prot ger les donn es du syst me en cas de pan...

Page 14: ...une notification de t l phone que votre syst me a t d clench Pour aider se rappeler les options que vous avez votre message doit tre semblable Le d tecteur d eau l adresse a t d clench veuillez entrer...

Page 15: ...tion automatique de l appeleur a t pr programm e en usine pour tre active Proc dez comme suit pour la d sactiver Entrez le mot de passe puis appuyez cinq 5 fois sur la touche PROG L ic ne clignotera l...

Page 16: ...r Entrez le mot de passe puis appuyez huit 8 fois sur la touche PROG Le message ENTRY clignotera l cran de l appeleur automatique Appuyez sur ARM DISARM pour confirmer Au moyen des touches UP et DOWN...

Page 17: ...une ligne t l phonique n est pas disponible l appeleur fait entendre 4 bips puis l alarme sonore se d clenche 4 COMMANDE DISTANCE PAR T L PHONE Description des fonctions d op ration distance SURVEILL...

Page 18: ...ative de capteurs inclus avec ce kit est de 60 m tres Les murs et autres obstacles peuvent interf rer avec la r ception Vous pouvez lier un total de 16 capteurs et 8 t l commandes pour l appeleur auto...

Page 19: ...de placage ce qui emp che la bonne d tection de l eau Mettez l unit en posi tion OFF A l aide d une lame de couteau grattez les 2 contacts de m tal 4 5 fois juste assez pour enlever l g rement le pla...

Page 20: ...instructions les plus r centes visitez notre site Internet www idealalert ca Garantie 1 an de garantie limit e sauf les piles sur les composants PRODUITS COMPATIBLES Soyez alert d inondation et d bor...