( Fig. 3a )

TEL.

LINE

( Fig. 3b )

TEL.

LINE

DC 9V Adaptor

(TEL.)

To telephone 

(LINE)

To wall socket

•  Wall mount option: Choose a suitable location where you have access to a telephone line and electrical outlet,  

drill holes using template provided and install anchors and screws. Place the auto-dialer over the screws and slide  

it down to secure it in place. 

AUTO-DIALER SET-UP

NOTE: If no key is pressed for 20 seconds, the auto-dialer will automatically exit set-up mode. 
•  Set-up is done in DISARM mode only. 
•  The auto-dialer has a factory preset password of 0-0-0. This should be changed to your own personal password.

1. TO CHANGE PASSWORD 
•  Enter factory pre-set password 0-0-0. Press PROG button once (1), PASSWORD will flash on the auto-dialer screen.  
•  Press the ARM/DISARM button to confirm that you want to enter the PASSWORD. 
•  Enter your new password then press the ARM/DISARM button to confirm your new password has been stored  

(you can choose from 3 to 6 digits for your password). 

•  Press the PROG button nine (9) times to exit set-up mode.
NOTE: PASSWORD RESET 
If you forget your password, locate the RESET button on the back of the unit. Press and hold the PROG button, and, press 

and release the reset button once. The screen will go blank. When screen returns let go of the PROG button. You now have 

the factory pre-set password of 0-0-0. This will reset the password ONLY, all other information will remain (programmed 

telephone numbers and learned sensors).

2. RECORD PERSONALIZED NOTIFICATION MESSAGE
You can record a single personalized 20 second message that will be played back when you receive telephone notification 

that your system has been triggered. To help remember the options you have, your message should be similar to:  

“The Water Detector at [address] has been triggered, please enter a command; to Disarm System and end call press 6 and #, 

to End Call press 3 and #, to Monitor Room press 1 and #, to Broadcast   press 2 and #”. 
•  Enter password then press REC/PLAY once. 
•  Clearly and slowly dictate your 20 second message. 
•  Press REC/PLAY to end recording. The recording will automatically end after 20 seconds. The message will replay once 

after recording is finished. 

•  Press REC/PLAY to replay message at anytime.

3. SETTING THE TIME (YEAR / MONTH / DATE / HOUR / MINUTES) 
•  Enter password then press the PROG button nine (9) times. 
• 

 Will flash on the auto-dialer screen. 

•  Press ARM/DISARM button to confirm.
•  The date will show on the auto-dialer screen as five sets of numbers: year, month, and date followed by the time hour and 

minutes (24 hr. time clock). The first set of numbers will flash confirming that these can now be changed.

•  Enter correct year by pressing */UP or #/DOWN button, then press the ARM/DISARM button. The next set of numbers will 

start flashing, enter the month by pressing */UP or #/DOWN button, then press the ARM/DISARM button. Continue until 

you have the correct date and time.

•  Press PROG button once (1) to exit set-up mode.

4. TO PROGRAM EMERGENCY TELEPHONE CALL NUMBERS 
•  Enter password followed by PROG button twice (2). 
•  MEMORY will flash on the auto-dialer screen. 

Summary of Contents for SK662

Page 1: ...d line and an electrical outlet and set to ARM mode it will alert you if water is detected The auto dialer will activate the built in siren or chime if set and dial out if set to up to 5 pre programme...

Page 2: ...install the system where it will be exposed to direct sunlight or rain 2 The built in siren is very loud never put the system close to your ear 3 The system should be installed away from heat sources...

Page 3: ...Zone 9 Can link up to 8 wireless sensors REMOTE zone Can link up to 8 remote controls Records the five most recent triggered alarms Built in flash memory to protect system data during a power failure...

Page 4: ...s and learned sensors 2 RECORD PERSONALIZED NOTIFICATION MESSAGE You can record a single personalized 20 second message that will be played back when you receive telephone notification that your syste...

Page 5: ...hold DEL PAUSE for 2 seconds until the letter F appears on the screen then enter 230 Press ARM DISARM button to confirm Press PROG button eight 8 times to exit set up mode 7 TO TURN THE AUTO DIAL FUNC...

Page 6: ...o 0 5 10 15 or 20 seconds Enter password followed by PROG button eight 8 times ENTRY will flash on the auto dialer screen Press the ARM DISARM button to confirm Using the UP and DOWN buttons select th...

Page 7: ...ITOR Enter 1 and after the beep you will be able to listen into the room where the auto dialer is installed After 30 seconds you will hear a beep to remind you that if you do not enter another code wi...

Page 8: ...The system has a total of 10 zones for wireless sensors and remote controls Zone 1 8 link one wireless sensor per zone they will trigger the auto dialer in armed mode only Zone 9 Learn up to 8 wireles...

Page 9: ...condition If The water sensor sends no signals when wet make sure that the metal contacts on the sensor are not corroded Gently scrape the contacts with a sharp knife to expose clean metal Contacts Ca...

Page 10: ...se check for updated instructions at www idealinc com WARRANTY 1 year limited warranty excluding batteries on components COMPATIBLE PRODUCTS Build a complete security system by adding additional senso...

Page 11: ...ligne de t l phone et une prise lectrique R glez l appeleur automatique sur le mode ARM Lorsque la pr sence d eau est d tect e l appeleur automatique d clenche la sir ne int gr e optionnelle et compos...

Page 12: ...vec appeleur automatique NOTEZ Pour modifier les param tres par d faut et tendre le syst me suivez les instructions d taill es fournies dans ce manuel CONSEILS DE S CURIT IMPORTANTS 1 N installez pas...

Page 13: ...fil Pour la zone REMOTE vous pouvez jumeler jusqu 8 d tecteurs sans fil Enregistrement des cinq derni res alarmes d clench es M moire Flash int gr e pour prot ger les donn es du syst me en cas de pan...

Page 14: ...une notification de t l phone que votre syst me a t d clench Pour aider se rappeler les options que vous avez votre message doit tre semblable Le d tecteur d eau l adresse a t d clench veuillez entrer...

Page 15: ...tion automatique de l appeleur a t pr programm e en usine pour tre active Proc dez comme suit pour la d sactiver Entrez le mot de passe puis appuyez cinq 5 fois sur la touche PROG L ic ne clignotera l...

Page 16: ...r Entrez le mot de passe puis appuyez huit 8 fois sur la touche PROG Le message ENTRY clignotera l cran de l appeleur automatique Appuyez sur ARM DISARM pour confirmer Au moyen des touches UP et DOWN...

Page 17: ...une ligne t l phonique n est pas disponible l appeleur fait entendre 4 bips puis l alarme sonore se d clenche 4 COMMANDE DISTANCE PAR T L PHONE Description des fonctions d op ration distance SURVEILL...

Page 18: ...ative de capteurs inclus avec ce kit est de 60 m tres Les murs et autres obstacles peuvent interf rer avec la r ception Vous pouvez lier un total de 16 capteurs et 8 t l commandes pour l appeleur auto...

Page 19: ...de placage ce qui emp che la bonne d tection de l eau Mettez l unit en posi tion OFF A l aide d une lame de couteau grattez les 2 contacts de m tal 4 5 fois juste assez pour enlever l g rement le pla...

Page 20: ...instructions les plus r centes visitez notre site Internet www idealalert ca Garantie 1 an de garantie limit e sauf les piles sur les composants PRODUITS COMPATIBLES Soyez alert d inondation et d bor...

Reviews: