Chapter 5
Fiber Optics Cable Field Calibration and Testing
A test result screen will appear at the completion of the test procedure.
Figure 5-8: Loopback Test Results Screen
LENGTH TEST (DUAL HANDSET)
Configuration Setup for Length Testing
1.
With the appropriate test adapter on the Display Handset and the appropriate test
adapter on the Remote Handset, connect one end of the near end launch cable
leads to the TX and RX connectors on the Display Handset adapter.
2.
Connect the other end of the launch cable leads to the patch panel that connects
to the fiber under test.
3.
Connect one end of the far end launch cable leads to the TX and RX connectors on
the Remote Handset adapter.
4.
Connect the other end of the far end launch cable to the wall plate (fiber cable
under test).
5.
Check all connections to ensure proper contact. Upon completion, you are ready to
perform a fiber test.
Figure 5-9: Configuration for Dual Handset Testing
6.
Press the LENGTH key on the Display Handset or select Analyze on the Ready
screen and press ENTER.
7.
Then, select Length, and press ENTER.
8.
At the completion of the test procedure, a test result screen will appear.
5-9
www.vemco.pl