Automatic Power Off

The thermometer will automatically shut off if left idle for more 

than 60 seconds unless it is in the PRB mode. If in the PRB 

mode, the unit will automatically shut off if left idle for more than 
12 minutes.

STORAGE 

 

The thermometer should be stored at room temperature between 
- 4 to 149°F (- 20 to 65°C).

LENS CLEANING

The lens should be kept clean at all times. Care should be 
taken when cleaning the lens using only a soft cloth or cotton 
swab with water. Allow the lens to fully dry before using the 
thermometer. 
Note: DO NOT submerge the unit in water.

LCD ERROR MESSAGES

The thermometer incorporates visual diagnostic messages as 
follows: ‘Hi’ or ’Lo’ is displayed when the temperature being 

measured is outside of the settings of HAL and LAL. ‘Er2’ is 

displayed when the thermometer is exposed to rapid changes 

in the ambient temperature. ‘Er3’ is displayed when the ambi

-

ent temperature exceeds 32°F (0°C) or 122°F (+50°C). The 
thermometer should be allowed to stabilize to the working/
room temperature (minimum 30 minutes). 

Error 5~9

, for all 

other error messages it is necessary to reset the thermometer. To 
reset it, turn the instrument off, remove the battery and wait for 
a minimum of one minute, reinsert the battery and turn on. If the 
error message remains please contact the Service Department 
for further assistance.

BATTERIES

The thermometer incorporates visual low battery warning as 
follows:

  Batteries OK  

Batteries Low 

Batteries Dead

  measurements  

battery needs to be 

measurements are  

   are possible  replaced, measurements 

not possible

 

 

are still possible

 

 When the ‘Low Battery’ icon indicates the batteries are 

low, the batteries should be replaced immediately with two AAA, 

1.5V batteries. Please note: It is important to turn the instrument 

off before replacing the batteries otherwise the thermometer may 
malfunction.

5

Selecting a Function

Each time the mode key is pressed, the thermometer advances 

through the function cycle. 

Emissivity setting display (default is 0.95).

Emissivity adjustment - use the up and down 

keys to adjust emissivity to the desired value. 
Press the mode key to confirm the setting.

Maximum temperature reading is displayed.

Minimum temperature reading is displayed.

Difference between the maximum and 
minimum reading is displayed.

Average temperature is displayed.

High and low alarm setting - 
use the up and down keys to 
adjust the desired values. Press 
the trigger key to confirm the 
setting. When readings exceed 
the alarm values, the icon will 
flash and an audible beep will 
activate.

Connect the optional k-type thermocouple 
to the thermocouple socket. The thermometer 
will display the probe temperature auto-

matically. View the maximum and minimum 

probe measurements by pressing either the 
up or down keys.

Lock Mode

While in the E, MAX, MIN, dIF OR AVG functions, press the up 

key to turn on or off the lock mode. While in lock mode, the 
device will monitor temperatures for up to 60 minutes.

Changing to °F or °C

Press the down key to change the setting.

Backlit Function

While depressing the trigger key first, press the up key to turn 
the backlit on or off.

Laser Function

While depressing the trigger key first, press the down key to turn 
activate or de-activate the laser.

Summary of Contents for 61-685

Page 1: ...dentifies hazardous conditions and actions that could cause bodily harm or death WARNINGS To avoid possible electric shock personal injury or death follow these guidelines Do not look directly into the laser beam permanent eye damage may result Do not use a thermocouple on a live circuit Do not use if meter appears damaged Visually inspect the meter to ensure case is not cracked Do not use meter i...

Page 2: ...being measured Refer to the following emissivity table 1 12 3 36 5 60 Distance Spot D 12 S 1 3 4 1 00 Reference source 0 98 Carbon filed surface 0 98 Frost crystals 0 98 Skin human 0 97 Slate 0 96 Water distilled 0 96 Ice smooth 0 95 Soil saturated with water 0 95 Carbon candle soot 0 94 Glass polished plate 0 94 Paint oil 0 93 Brick red 0 93 Paper white bond 0 92 Concrete 0 92 Soil dry 0 91 Plast...

Page 3: ... are possible replaced measurements not possible are still possible When the Low Battery icon indicates the batteries are low the batteries should be replaced immediately with two AAA 1 5V batteries Please note It is important to turn the instrument off before replacing the batteries otherwise the thermometer may malfunction 5 Selecting a Function Each time the mode key is pressed the thermometer ...

Page 4: ...s warranted to the original purchaser against defects in material and workmanship for two years from the date of purchase During this warranty period IDEAL INDUSTRIES INC will at its option replace or repair the defective unit subject to verification of the defect or malfunction This warranty does not cover fuses batteries or damage from abuse neglect accident unauthorized repair alteration or unr...

Page 5: ...ciones peligrosas que pueden causar lesiones corporales o la muerte ADVERTENCIAS Para evitar posibles riesgos de electrocución lesiones o la muerte siga estas pautas No mire directamente al haz láser puede sufrir daños oculares permanentes No use una termocupla en un circuito alimentado No use el instrumento si el mismo parece estar dañado Inspec ciónelo visualmente para asegurarse de que la carca...

Page 6: ...idad correspondi ente al tipo de superficie que se mide Consulte la tabla de emisividad siguiente 1 12 3 36 5 60 Distancia Mancha D 12 S 1 3 4 1 00 Fuente de referencia 0 98 Superficie de carbón limada 0 98 Cristales esmerilados 0 98 Piel humana 0 97 Pizarra 0 96 Agua destilada 0 96 Hielo liso 0 95 Suelo saturado con agua 0 95 Hollín de vela de carbón 0 94 Placa de vidrio pulida 0 94 Pintura al ac...

Page 7: ...n poca Baterías agotadas es posible medir carga no es posible medir es necesario reemplazar las baterías aunque todavía es posible medir Cuando el icono de baterías con poca carga indica que las baterías tienen poca carga es necesario reemplazarlas inmedi atamente por dos baterías AAA de 1 5 V Observe lo siguiente Es importante apagar el instrumento antes de reemplazar las baterías puesto que de l...

Page 8: ...e material o mano de obra por dos años contados a partir de la fecha de compra Durante este período de garantía IDEAL INDUSTRIES INC reemplazará o reparará la unidad defectuosa a la sola opción de IDEAL sujeto a la verificación del defecto o falla Esta garantía no cubre fusibles baterías o daños que sean consecuencia de abusos negligencia accidentes reparaciones no autorizadas alteraciones o uso n...

Page 9: ...d entraîner des lésions corporelles ou la mort AVERTISSEMENTS Se conformer aux directives suivantes pour éviter tout risque d électrocution de lésions personnelles ou de mort Ne pas regarder directement le rayon laser une lésion permanente des yeux pourrait en résulter Ne pas utiliser un thermocouple sur un circuit sous tension Ne pas utiliser le multimètre s il paraît endommagé Inspecter visuelle...

Page 10: ...e thermometer permet le réglage de l émissivité pour le type de surface mesurée Se reporter à la table d émissivité suivante 1 12 3 36 5 60 Distance Spot D 12 S 1 3 4 1 00 Source de référence 0 8 Surface carbone limée 0 98 Cristaux de gelée 0 98 Peau humaine 0 97 Ardoise 0 96 Eau distillée 0 96 Glace lisse 0 95 Sol saturé d eau 0 95 Carbone de suie de bougie 0 94 Verre poli 0 94 Peinture huile 0 9...

Page 11: ...es Quand l icône Low Batteries indique que les piles sont déchargées celles ci doivent être remplacées immédiatement par deux piles AAA de 1 5 volt Noter Il est important d arrêter l instrument avant de remplacer autrement le thermomètre pourra fonctionner de façon erratique 5 Sélection d une fonction Chaque fois qu on appuie sur la touche mode le thermomètre avance dans le cycle des fonctions Aff...

Page 12: ...ière ou de façon pendant deux ans à compter de la date d achat Durant cette période de garantie IDEAL INDUSTRIES INC à son choix remplacera ou réparera l unité défectueuse suite à la vérification du défaut ou du dysfonctionnement Cette garantie ne s applique pas aux fusibles aux piles ou aux dommages résultant d une utilisation abusive de la négligence d un accident d une réparation non autorisée ...

Reviews: