![IDEAL INDUSTRIES 61-484 Service Information Download Page 8](http://html.mh-extra.com/html/ideal-industries/61-484/61-484_service-information_617128008.webp)
Page 6
(8) DC Current
Range
Resolution
61-486 Accuracy
61-484 Accuracy
6.000A
0.001A
±(0.8% r 3 digits)
±(1.0% r 3 digits)
10.00A
0.01A
Maximum measurement time:
3 minutes at 10A with at least 20 minutes rest time.
Overload Protection:
AC/DC 11A.
(9) AC Current
Range
Resolution
61-486 Accuracy (Sine Wave)
61-484 Accuracy (Sine Wave)
6.000A*
0.001A
±(1.2% r 3 digits)
±(1.5% r 3 digits)
10.00A
0.01A
Frequency Response:
50 ~ 1kHz (Sine Wave)
AC Conversion Type:
RMS sensing, RMS indication
Additional Accuracy by Crest Factor (C.F.):
Same as ACV.
Max. Crest Factor:
Same as ACV.
Maximum measurement time:
3 minutes at 10A with at least 20 minutes rest time.
Overload Protection:
AC/DC 11A.
(10) AC+DC Current
Range
Resolution
61-486 Accuracy
61-484 Accuracy
6.000A
0.001A
±(2% r 5 digits)
±(2.5% r 5 digits)
10.00A
0.01A
Additional specifications are same as Ampere function.
The AC+DC True RMS vale might be over selected range since the AC single on DC level. The meter will display
“OL” or change the range while (AC value + DC value) > 6500 counts.
Overload Protection:
AC/DC 11A.
(11) DC mA
Range
Resolution
61-486 Accuracy
61-484 Accuracy
60.00mA
0.01mA
±(0.8% r 3 digits)
±(1.0% r 3 digits)
600.0mA
0.1mA
Maximum measurement time:
10 minutes at 600mA with at least 20 minutes rest time.
Overload Protection:
AC/DC 440mA.