8
Installation and Servicing
SECTION 1 - GENERAL
Table 1 - General Data
Note.
Gas consumption is calculated using a
calorific value of 38.7 MJ/m
3
gross or 34.9 MJ/m
3
nett
To obtain the gas consumption at a different
calorific value:
a.
For l/s
- divide the gross heat input (kW) by
the gross C.V. of the gas (MJ/m
3
)
b.
For ft
3
/h
- divide the gross heat input (Btu/h)
by the gross C.V. of the gas (Btu/ft
3
)
c.
For m
3
/h
- multiply l/s by 3.6
Key to symbols
GB
= United Kingdom
IE
= Ireland
(Countries of destination)
PMS
= Maximum operating pressure of water
C
13
C
33
C
53
* = A room sealed appliance designed for connection via ducts to a
horizontal or vertical terminal, which admits fresh air to the burner
and discharges the products of combustion to the outside through
orifices which, in this case, are concentric. The fan is up stream
of the combustion chamber. (*Note.
C
53
covers optional high level
and balconly flue kits only.)
I
2H
= An appliance designed for use on 2nd Family gas, Group H only.
* The value is used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating of dwellings. The test data from
which it has been calculated have been certified by a notified body.
Maximum DHW Input :
C26
C32
C40
Nett CV
kW
26.1
32.1
40.2
Gross CV
kW
29.0
35.6
44.6
Gas Consumption m
3
/h 2.695 3.314 4.150
Maximum
kW
26.0
32.0
40.0
DHW Output
DHW Flow Rate
l/min
10.6
13.1
16.4
at 35°C temp. rise.
DHW Specific Rate
l/min
12.4
15.3
19.1
Boiler Input :
Max.
Min.
C26
C32
C40
C26
C32
C40
Boiler Input ‘Q’
Nett CV
kW
18.1
26.1
32.1
3.7
4.6
5.7
Gross CV
kW
20.1
29.0
35.6
4.1
5.1
6.3
Gas Consumption
m
3
/h 1.869 2.695 3.314 0.383 0.472 0.590
Boiler Output :
Non Condensing
kW
18.0
26.0
32.0
3.7
4.6
5.7
70
o
C Mean Water temp.
Condensing
kW 19.3
27.9
34.3
4.0
4.9
6.1
40
o
C Mean Water temp.
Seasonal efficiency* SEDBUK 2005 91.0
91.1
91.0
n/a
Seasonal efficiency* SEDBUK 2009 89.1
89.2
89.1
n/a
NOx Classification
Class 6
Table 2 - Performance Data - Central Heating
Table 3 - Performance Data - Domestic Hot Water
* In areas of low water pressure the DHW restrictor can be removed
C26
C32
C40
Gas supply
2H - G20 - 20mbar
Gas Supply Connection
22mm copper compression
Injector Size
mm
4.30
4.40
5.15
Inlet Connection
Domestic Hot Water
15mm copper compression
Outlet Connection
Domestic Hot Water
15mm copper compression
Flow Connection
Central Heating
22mm copper compression
Return Connection
Central Heating
22mm copper compression
Flue Terminal Diameter
mm
100
Average Flue Temp-Mass Flow Rate (DHW)
ºC (g/s)
73ºC (11 g/s)
73ºC (13 g/s)
70ºC (17 g/s)
CO
2
Content (± 0.7)
Max. DHW
9.4 %
9.8 %
9.6 %
Min. DHW
8.0 %
8.5 %
8.1 %
Maximum CH Working Pressure (Sealed Systems)
bar
2.5
Maximum DHW Inlet Working Pressure
bar
10.0
Minimum DHW Flow Rate
l/min
1.9
1.9
1.9
*Required Connection Pressure for Minimum Flow Rate
bar
0.03
0.03
0.03
DHW Flow Rate at 35ºC Temp Rise
l/min
10.65
13.1
16.4
*Required Connection Pressure for 35ºC Temp Rise
bar
0.62
0.83
1.23
80% of Max Flow Rate
l/min
8.52
10.48
13.12
*Required Connection Pressure for 80% of Max Flow Rate
bar
0.39
0.54
0.79
Electrical Supply
230 V ~ 50 Hz.
Power Consumption
W
94
115
96
Fuse Rating
External : 3A Internal
: 4A Time Delay
Water content
Central Heating litre
1.5
1.8
2.2
Domestic Hot Water litre
0.5
Packaged Weight
kg
37.6
38.9
40.9
Maximum Installation Weight
kg
32.4
33.8
35.4
Boiler Casing Size
Height mm
740
Width mm
445
Depth mm
330
Heat Exchanger Weight without Burner
kg
7.3
8.2
9.5
Summary of Contents for VOGUE COMBI GEN2 C26
Page 4: ...4 Installation and Servicing...
Page 6: ...6 Installation and Servicing...
Page 74: ......