37
icos
-
Installation & Servicing
SERVICING
1.
Refer to Frame 47.
2.
Remove the boiler front and sealing panels. Refer to
Frames 40 & 41.
3.
Pull off the silicon tube from the thermistor housing.
4.
Remove the aluminium nipple securing the thermistor to
the flue manifold.
5.
Withdraw the thermistor.
6.
Unplug the inline
electrical connector.
7.
Fit the new
thermistor, using the
gasket supplied.
8.
Reassemble in
reverse order.
9.
Check operation of
the boiler. Refer to
Frame 47.
1.
Refer to Frame 47.
2.
Remove the boiler front and
sealing panels. Refer to Frames
40 & 41.
3.
Pull off the electrical leads from
the thermostat body.
4.
Pull the thermostat and clip from
the pipe.
5.
Fit the new thermostat, ensuring
that the clip is securely holding
the thermostat to the flow pipe.
6.
Reassemble in reverse order.
7.
Check operation of the boiler.
Refer to Frame 47.
58 OVERHEAT THERMOSTAT REPLACEMENT
59 FLUE THERMISTOR REPLACEMENT
SER
VICING
200212-10.pmd
9/5/2005, 8:59 AM