19
Mexico Super FF440 - FF480 -
Installation & Servicing
INSTALLATION
T
O
P
FLUE OUTLET
31 FITTING THE FLUE ASSEMBLY
Inside fitting.
1.
Insert the flue assembly through the hole far
enough to allow the rubber seal to unfold
completely and form an adequate seal on the
outside wall.
2.
Ensure the notch is at the top.
32 FITTING THE SIDE OUTLET PLATES
Note.
If the boiler is fitted closer than 25mm to the side wall
the side outlet plate must be fitted now.
1.
Split the side outlet plate into 2 down the split line.
2.
Fit the 2 halves of the side outlet plate to the wall,
ensuring they are behind the boiler sealing ring.
33 LOCATING THE BOILER
Position the boiler beneath the flue assembly.
1.
Connect the flue terminal to the boiler, using the
length (A) of flue duct previously cut and ensuring
that the inner flue locates into the short extension
tube.
2.
Secure the flue to the boiler using the 2 M4 x 16mm
screws previously removed.
34 CONNECTING THE FLUE TO THE BOILER
200939-1.p65
3/1/2004, 4:33 PM
19