Mexico Slimline RS 3/40 & 3/50 -
Installation
GENERAL
Key to symbols
GB
= United Kingdom
IE
= Ireland (Countries of destination)
PMS
= Maximum operating pressure of water
C
11
= A room sealed appliance designed for connection via ducts
to a horizontal terminal, which admits fresh air to the burner
and discharges the products of combustion to the outside
without a fan in the combustion products circuit.
I
2H
= An appliance designed for use on 2nd Family gas, Group H
only.
Boiler Size
RS 3/40
RS 3/50
Gas Supply Connection
in. BSP
Rc 1/2 (1/2)
Flow and Return Connections
Rc 1 (1" BSP)
MAXIMUM Static Water Head
m (ft.)
30.5 (100)
(3 bar)
MINIMUM Static Water Head
m (ft.)
1.0 (3.3)
Electrical Supply
power consumption
230 V ~ 50 Hz
5W
External Fuse Rating
3 A
Water Content
litre (gal.)
20 (4.4)
Dry Weight
excluding
balanced flue terminal kg. (lb.)
100 (220)
Boiler Size
Height
mm (in.)
850 (33.5)
Width
mm (in.)
255 (10.0)
Depth
mm (in.)
535 (21.0)
Gas Type
Natural 2 H
Gas Supply Pressure
20 mb
Table 1 - General Data
Boiler Size
RS 3/40
RS 3/50
Boiler Input
MINIMUM
kW (Btu/h)
11.3 (38 500)
15.0 (51 200)
Gas Consumption
l/s (ft.
3
/h)
0.29 (37.0)
0.39 (49.3)
MID
kW (Btu/h)
12.7 (43 500)
16.7 (57 100)
Gas Consumption
l/s (ft.
3
/h)
0.33 (47.7)
0.43 (54.7)
MAXIMUM
kW (Btu/h)
14.5 (49 400)
18.5 (63 200)
Gas Consumption
l/s (ft.
3
/h)
0.37 (47.5)
0.48 (60.8)
Boiler Output
MINIMUM
kW (Btu/h)
8.8 (30 000)
11.7 (40 000)
to Water
MID
kW (Btu/h)
10.3 (35 000)
13.2 (45 000)
MAXIMUM
kW (Btu/h)
11.7 (40 000)
14.7 (50 000)
Burner Setting
MINIMUM
mbar (in w.g.)
6.3 (2.5)
8.0 (3.2)
Pressure (hot)
MID
mbar (in w.g.)
8.0 (3.2)
10.0 (4.0)
MAXIMUM
mbar (in w.g.)
10.4 (4.2)
12.4 (5.0)
Flue gas flow rate (maximum)
g/s
6.8
8.7
Flue gas temperature
o
C
150
189
*
Seasonal efficiency
(SEDBUK) %
74.4
72.8
Table 2 - Performance Data
Note.
Gas consumption is calculated using a calorific value of
38.7 MJ/m
3
(1038 Btu/ft
3
) gross or 34.9 MJ/m
3
(935 Btu/ft
3
)
nett
To obtain the gas consumption at a different calorific value:-
a.
For l/s - divide the gross heat input (kW) by the gross
C.V. of the gas (MJ/m
3
)
b.
For ft
3
/h - divide the gross heat input (Btu/h) by the gross
C.V. of the gas (Btu/ft
3
)
*
The value is used in the UK government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
The test data from which it has been calculated have been certified by BGplc 0087