10
Installation and Servicing
SECTION 1 - GENERAL
1.1 INTRODUCTION
The
Logic Max Heat H
range of boilers are wall mounted, full
sequence, automatic spark ignition, low water content, fanned
flue, high efficiency, condensing, heating only gas boilers.
Note.
Due to the high efficiency of the boiler a plume of water
vapour will form at the terminal during operation.
Central heating (CH) output is fully modulating with a range of:
12
4.8 to 12kW
15
4.8 to 15kW
18
4.8 to 18kW
24
4.8 to 24.2kW
30
6.1 to 30.3kW
A variable CH temperature control is fitted on the user control.
The boiler includes as standard:
-
Boiler frost protection
Notes
.
The appliance must be wired with a permanent live
supply, or the boiler frost protection will not operate.
The boiler warranty will be invalid if these requirements
are not complied with.
The boiler casing is of white painted mild steel with a polymer
front panel.
The boiler temperature control is visibly located in the control
panel on the front of the boiler.
The heat exchanger is manufactured from cast aluminium.
Note that these boilers cannot be used on systems which include
gravity circulation.
The boiler is suitable for connection to fully pumped open vented
or sealed water systems. Adequate arrangements for completely
draining the system by provision of drain cocks MUST be provided
in the installation pipework.
Pipework from the boiler is routed upwards.
A rear flue outlet kit (55/80) is available which provides a compact
installation.
The Ideal system filter is supplied with this boiler. Installation
instructions for this are located within the system filter box.
Be sure to follow Ideal system filter installation and maintenance
guide for correct method of installation. Failure to install the
system filter correctly will affect boiler warranty.
Data Plate
The boiler model and serial number can be located on the bottom
of the boiler casing, shown in Section 1.16 - Condensate & Gas
Connection Diagram.
1.2 OPERATION
When there is a demand for CH, the heating system is supplied at
the selected temperature of between 30
o
C and 80
o
C.
The boiler features a comprehensive diagnostic system which
gives detailed information on the boiler status when operating, and
performance of key components to aid commissioning and fault
finding.
1.3 SAFE HANDLING
This boiler may require 2 or more operatives to move it to its
installation site, remove it from its packaging base and during
movement into its installation location. Manoeuvring the boiler
may include the use of a sack truck and involve lifting, pushing and
pulling.
Caution should be exercised during these operations.
Operatives should be knowledgeable in handling techniques when
performing these tasks and the following precautions should be
considered:
• Grip the boiler at the base.
• Be physically capable.
• Use personal protective equipment as appropriate, e.g. gloves,
safety footwear.
During all manoeuvres and handling actions, every attempt should
be made to ensure the following unless unavoidable and/or the
weight is light.
• Keep back straight.
• Avoid twisting at the waist.
• Avoid upper body/top heavy bending.
• Always grip with the palm of the hand.
• Use designated hand holds.
• Keep load as close to the body as possible.
• Always use assistance if required.
1.4 OPTIONAL EXTRA KITS
Please visit www.idealboilers.com to access the Flue and
Accessories Guide for this boiler.
Summary of Contents for LOGIC MAX HEAT H 12
Page 4: ...4 Installation and Servicing ...
Page 6: ...6 Installation and Servicing ...
Page 61: ...61 NOTES Installation and Servicing ...
Page 62: ...62 Installation and Servicing SECTION 5 SPARE PARTS ...
Page 68: ...68 NOTES Installation and Servicing ...