12
Classic
LXFF, FF
-
Installation
Flue length
for rear
Flue length for side
Jacking screw for
boiler alignment
INST
ALLA
TION
INSTALLATION
STANDARD MODEL
1.
Unpack the boiler.
2.
Remove the casing as follows and place to one side to
avoid damage.
a.
Undo the 2 casing retaining screws (a) retaining the
casing to the back panel.
b.
Swing the bottom of the boiler casing up until the
controls pod casing has cleared the controls then
unhook the top from the back panel.
3.
Remove the boiler from its packaging base. The boiler may
now be stood upright on its controls support protection
frame to ease handling and installation.
4.
Unpack the boiler terminal box and, if applicable, the
extension flue box(es).
7
PACKAGING AND CASING REMOVAL
SIDE FLUE
INSTALLATION
REAR FLUE
INSTALLATION
FLUE KITS
Pack B:
supplied as standard.
Pack D*:
optional extension kit for side flue or rear
flue outlet. Refer to 'Flue Extension Ducts'
1.
A maximum of 2 extension ducts (plus the
standard flue duct) may be used together.
2.
Flue extensions of greater than 1m (39") should
be supported with the bracket provided. If the
stand-off brackets have been used it is
necessary, in order to keep the flue aligned, to
use the spacer bracket with the support bracket.
It is MOST IMPORTANT that the boiler is installed
in a vertical position.
(a) Casing retaining
screws, 2 off
Packing base
Controls pod casing
DELUXE MODEL (LX)
1.
Unpack the boiler.
2.
Remove the casing as follows and place to one side to
avoid damage.
a.
Slide the glass fascia upward (arrow b)
b.
Undo the 2 casing retaining screws (c), retaining the
casing to the back panel.
c.
Swing the bottom of the boiler casing up until the
controls pod casing has cleared the controls then
unhook the top from the back panel.
3.
Remove the boiler from its packaging base. The boiler
may now be stood upright on its controls support
protection frame to ease handling and installation.
4.
Unpack the boiler terminal box and, if applicable, the
extension flue box(es).
8
DETERMINING THE FLUE LENGTH
*
Not for FF 2 100 model
Flue length mm
Accessories
Product No.
Up to 600
B Pack 1 off
152 227
600 to 1550*
B Pack 1 off + D Pack, 1 off
152132
1550 to 2500*
B Pack 1 off + D Pack, 2 off
152 227+
152132, 2 off
2500 to 3000*
B Pack 1 off + D Pack, 3 off
152 227+
152132, 3 off