  Do not put the battery in a microwave oven or a drying machine. 

  Do not put the battery into a fire. 

  If the battery leaks, do not let the liquid stain your skin or eyes. Otherwise, wash your 

skin or eyes with lots of water and go to see the doctor immediately. 

Cleaning the iData 95UHF 

  Shell   

Clean the shell by using a cloth soaked with alcohol, including keys and space between 

keys.   

  Display 

You can clean  the display screen by  using a cloth soaked  with alco hol. Do  not  let the 
liquid gather around the screen. Otherwise, dry  the screen by  using a soft non-woven 
cloth in case strip marks are left on the screen. 

  Scan lens   

Clean the scan  lens  regularly by  using  lens paper or other articles suitable  for cleaning 

optical materials. 

7.2 Troubleshooting 

Table 7-1 iData 95UHF troubleshooting   

Fault 

Cause 

Solution 

After  the  power  key  is 

pressed, 

the 

iData 

95UHF  is  not  powered 

on. 

The  battery  volume  is  too 

low  or  the  battery  is  not 

charged.   

Charge  the  iData  95UHF  or  replace  the 

battery. 

The  battery  is  incorrectly 

installed.   

Correctly install the battery.   

The system breaks down. 

Restore factory settings. 

Battery charging fails. 

The battery fails. 

Replace the battery. 

The  temperature  of  the 

battery is too high or low. 

Put the battery in normal temperature. 

During 

data 

communication,  data  is 

not 

transmitted 

or 

transmitted 

data 

is 

incomplete. 

The  cable  configuration  is 

incorrect.   

Consult the system administrator.   

The 

communication 

software 

is 

incorrectly 

installed or configured. 

Install or reinstall the ActiveSync software to 

update the driver. 

The  relevant  function  is 

not activated after a user 

clicks a button or icon. 

The 

system 

does 

not 

respond. 

Restart the system. 

No sound can be heard. 

The volume is too  low or is 

disabled. 

Adjust the volume. 

The  iData  95UHF  is 

closed. 

The  iData  95UHF  is  in  the 

inactive state. 

After being inactive for a period of time, the 

iData 95UHF is closed. 

The battery is used up. 

Replace the battery. 

Summary of Contents for 95UHF

Page 1: ......

Page 2: ...7 Label Reading Direction 11 3 Call Function 12 3 1 Making a Call 12 3 2 Contacts 12 3 3 SMS and MMS 13 3 4 Email 14 4 Network and Connection Synchronization 16 4 1 GPRS Data Connection 16 4 2 Wi Fi N...

Page 3: ...iData 95UHF UserManual 1 1 Introduction 1 1 Appearance of iData 95UHF Figure 1 1 Front view of iData 95UHF Figure 1 2 Rear view of iData 95UHF...

Page 4: ...stall an SD card do as follows 1 Push the card cover along the direction marked on the cover and open the cover 2 Insert an SD card 3 Press the SD card downward and lock the card along the IN directio...

Page 5: ...over downward 3 Push the SIM card along the LOCK direction to lock the card cover Figure 1 4 Inserting a SIM card 1 4 Installing a Battery To install a battery do as follows 1 Push the battery to the...

Page 6: ...1 Hold the rear button of the battery cover by using your thumb 2 Pull out the battery cover Figure 1 6 Disassembling the battery cover 1 6 Charging You can charge the iData 95UHF in the following wa...

Page 7: ...to a smaller value for the iData 95UHF by selecting Home Applications Settings Display Screen Delay Stop all wireless activities when you do not use the iData 95UHF 2 Instructions on the iData 95UHF...

Page 8: ...e physical keypad of the iData 95UHF the left and right function keys and the yellow scan key correspond respectively to the menu key return key and scan key Scan key Used to scan data Return key Used...

Page 9: ...nnection Internet access restricted Missed calls USB debug New messages Charging Modem logs Full power Mute mode There are multiple notification icons which are beyond the scope of display Connect to...

Page 10: ...owing icon Select Settings Display and set display options such as Brightness Wallpaper Auto rotate screen and Font size 2 6 3 Ringtone Setting Select Settings Audio Profiles and click General Silent...

Page 11: ...al 9 2 6 4 Security Setting Select Settings Reset Factory date reset Click Clear all The iData 95UHF starts to restore the factory settings Caution This operation will clear the following data in the...

Page 12: ...sired language Click Default and select the desired input in the list 2 6 6 Shortcuts You can add shortcut icons on the home page of the iData 95UHF On the home page click the application tray icon se...

Page 13: ...ice parallel to the polarization direction of the label 2 PCB Antenna To read a label from a long distance try to make the polarization direction of the device parallel to the polarization direction o...

Page 14: ...he call 3 2 Contacts Find the following icon 1 Click Contacts to open the contact list 2 To add a contact click 3 To import or export contacts press the menu key to open the menu and click Import expo...

Page 15: ...ssage recipient and the text to be sent 2 Click to send the message 3 On the message editing page press the menu key to open the menu and click Add Subject Convert the message to be sent into a multim...

Page 16: ...email receiving options select all and click Save To set a mailbox on the iData 95UHF do as follows Find the following icon 1 Enter the email address and password and click Next The system starts to...

Page 17: ...iData 95UHF UserManual 15...

Page 18: ...perform the following configuration Select Settings More Mobile Networks Network Mode and manually select the CDMA or GSM network After a GPRS data connection is established you can access the Interne...

Page 19: ...PN APN enabled Bearer system null 4 2 Wi Fi Network Connection Select Settings Wireless networks WLAN 1 Click On for Wi Fi The system starts to search for the network If the WLAN is enabled click Scan...

Page 20: ...oftware and HiMarket see relevant description in 6 1 Installing Software from HiMarket and view position information 4 4 Connecting iData 95UHF to a Computer Connect the iData 95UHF to a computer by u...

Page 21: ...ick Next Wait until the connection is completed for details about mailbox settings see section 3 4 Email 3 Click Accounts sync On the Accounts sync settings page set the account as required Click the...

Page 22: ...logy Company Ltd provides the scan demonstration software iScan for example to obtain and decode barcode information First of all install iScan on the iData 95UHF for details on how to install iScan s...

Page 23: ...stall software on the computer First of all install software such as APK installer pea or 91 mobile assistant on the computer so that software can be installed in batches 6 2 Uninstalling Programs If...

Page 24: ...ey yellow scan key and click Manage apps You can view the status of download applications applications in the SD card and running applications and click any application to access the application infor...

Page 25: ...mponents of the iData 95UHF may be damaged and the iData 95UHF may be faulty Do not use strong chemical products or strong detergent to clean the iData 95UHF If the iData 95UHF become dirty clean the...

Page 26: ...ata 95UHF is not powered on The battery volume is too low or the battery is not charged Charge the iData 95UHF or replace the battery The battery is incorrectly installed Correctly install the battery...

Page 27: ...age capacity by using an SD card Too many applications are installed on the iData 95UHF Remove applications installed on the iData 95UHF The iData 95UHF does not decode barcodes The scan application i...

Page 28: ...is in poor contact Replace the cable The synchronization software cannot be connected The cable is in poor contact Replace the cable Table 7 3 Wi Fi connection troubleshooting Fault Cause Solution An...

Page 29: ...droid 4 0 Memory 4 GB ROM 512 MB RAM Expansion Slot Mini SD card up to 32 GB Display 3 5 inch HVGA 320x480 high brightness TFT LCD LED backlight Touch Panel Industrial grade capacitive touch panel sup...

Page 30: ...ation RFID UHF Protocol ISO18000 6C EPC C1G2 Frequency 902 928 MHz Antenna Circularly polarized 2 dBi Linearly polarized 1 4 dBi Max Output Power 1 W 30 dBm Data Capture Range Within 2 5 m 3 5 m for s...

Page 31: ...content in this document is subject to update without notice Without written approval of Wuxi iData Technology Company Ltd no one shall copy extract back up modify spread or translate any part of thi...

Page 32: ......

Reviews: