7.12
Intelligent Tamper
Enabling the intelligent reader tamper mode will force the card reader to check in to the device it is connected to
every 30 seconds.
In RS-485 programming mode, the following options are available by pressing the M key from the main
menu.
In 125kHz programming mode, the following options are available by badging the programming card four
times to enter Address 4.
Function
125kHz Setting
RS-485 Setting
Disabled
1
1
Enabled
2
2
i
Only enable Intelligent Reader Tamper Mode if the access control system or reader interface supports
intelligent tamper operation.
7.13
Factory Reset
Applies to RS-485 programming mode only.
This resets all settings in the device excluding custom encryption keys. To reset the reader, press the O key
from the main menu.
7.14
Output Mode
Applies to RS-485 programming mode only.
The Output Mode defines the output format of the reader. Three formats are available - Wiegand, ICT Smart or
Custom RS-485. To change the Output Mode, press the L key from the main menu.
7.15
Clone Card Notify
Clone Card Notify enables the reader to notify the reader expander if a card presented is a non-standard Mifare
compatible card. This setting is only supported when using RS-485 configuration and requires the Clone Card
Reading option to be enabled.
To toggle the Clone Card Notify option, press the 1 key.
7.16
Clone Card Reading
The Clone Card Reading option determines whether non-standard Mifare compatible cards are read by the
reader.
To toggle the Clone Card Reading option, press the 2 key.
7.17
Clone Card Destroy
If this setting is enabled and a non-standard Mifare compatible card is presented, the reader modifies the card
so it cannot be read.
To toggle Clone Card Destroy, press the 3 key.