To program the reader using 125kHz mode: 

1.

 

Present the card to the reader the number of times matching the data value option for the selected address.   

2.

 

Wait for the reader to beep twice. 

3.

 

Present the card the required number of times to set the desired option (as outlined by the 125kHz setting 
column in the tables below). 

4.

 

Wait for the reader to beep twice indicating the data has been programmed correctly. At this stage the 
reader is waiting for a new address to program.   

5.

 

If additional settings are required, repeat the above steps. 

An invalid entry will result in a long tone being generated. The data can be entered again or allow the 
reader to timeout to select another address.   

6.

 

Once complete, leave the programming interface to time out. 

Example: To program Address 1 (Card/Tag Format), present the programming card to the reader once. The 
card reader will respond by beeping twice to indicate data entry mode has been entered and that you can 
present the card the required number of times to set the desired option.   

 

Address  

Programming Options 

Card Reading Format 

Data Output Format 

Intelligent Tamper Mode 

PIN Data Interface 

12 

Restart Only 

 

 

7.3

 

125kHz Reading Mode 

Reading mode determines how the data on the 125kHz card is processed by the reader.   

 

In RS-485 programming mode, the following options are available by pressing the A key with the main 
menu displayed. To change the programmed reading mode, press the A key and the available modes will 
toggle on the screen. 

 

In 125kHz programming mode, the following options are available by badging a programming card once to 
enter Address 1. 

   

Function 

125kHz Setting 

Description 

All Card Format 

All 125KHz cards will be read (no filtering) 

ICT 

Can only read ICT programmed cards 

POSTECH 

Can only read POSTECH programmed cards 

HID 

Can only read HID programmed cards 

ICT & HID 

Can only read ICT and HID programmed cards 

ICT & POSTECH 

Can only read ICT and POSTECH programmed cards   

POSTECH & HID 

Can only read POSTECH and HID programmed cards 

Disable 

No 125KHz cards will be read 

 

 

Summary of Contents for PRX-TSEC

Page 1: ...PRX TSEC tSec Multi Technology Card Reader Installation Manual...

Page 2: ...roduced photocopied or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Integrated Control Technology Limited Designed and man...

Page 3: ...________________________________________________ 10 4 1 Mounting Instructions 10 4 2 Vandal Resistant Cover Mounting 11 5 Wiegand Connection______________________________________________________ 14 6...

Page 4: ...________ 26 11 European Standards ______________________________________________________ 27 12 UL and ULC Installation Requirements ______________________________________ 28 12 1 CAN ULC S319 05 28 12...

Page 5: ...ection Keep alive transmission every 30 seconds for intelligent tamper management Fully encapsulated design with environment IP Rating of IP65 for outdoor and indoor operation Bi color LED blue and gr...

Page 6: ...Sec Extra 125KHz Card Reader PRX TSEC EXTRA 125 KP tSec Extra 125KHz Card Reader with Keypad PRX TSEC EXTRA 125 KP VRC tSec Extra 125kHz Card Reader with Keypad and Vandal Resistant Cover PRX TSEC EXT...

Page 7: ...re Card Reader PRX TSEC STD DF KP tSec Standard DESFire Card Reader with Keypad PRX TSEC STD DF KP VRC tSec Standard DESFire Card Reader with Keypad and Vandal Resistant Cover Mini PRX TSEC MINI tSec...

Page 8: ...2 Mifare Modules The Mifare products can be expanded to accommodate large numbers of modules using the encrypted RS 485 Network Modules that are currently available are listed below Integrated Control...

Page 9: ...transmission flexible memory organization and interoperability with existing infrastructure Fully compliant with the international standard ISO IEC 14443 Type A 1 4 Available in 2 4 and 8 Kbytes EEPR...

Page 10: ...it 2 Hold the rear case half against the wall and mark the mounting holes and cable entry area The cable entry area should align with a hole cut through the plaster wall board Cables are intended to b...

Page 11: ...ers are suitable for mounting the tSec card readers on interior or exterior walls i In order to use the capacitive touch keypad with the anti vandal cover you must use the variant that is provided in...

Page 12: ...C tSec Multi Technology Card Reader Installation Manual June 2017 29mm 1 14 41 5mm 1 63 41 5mm 1 63 29mm 1 14 91 3 58 162mm 6 37 70mm 2 75 8X 5 2mm 0 2 Mounting Holes 22 6mm 0 88 PRX SRVC Vandal Resis...

Page 13: ...ec Multi Technology Card Reader Installation Manual June 2017 13 120mm 4 72 29mm 1 14 41 5mm 1 63 41 5mm 1 63 29mm 1 14 99mm 3 9 162mm 6 37 8X 5 2mm 0 2 Mounting Holes 22 6mm 0 88 PRX XRVC Vandal Resi...

Page 14: ...on Default AUX DO L2 D1 L1 BZ YELLOW PURPLE ORANGE WHITE RED GREEN BLACK BROWN BLUE SHIELD 12V 0V DATA 0 DATA 1 GREEN LED BLUE LED BEEPER NA NB Dual LED Connection Using the recommended cables as list...

Page 15: ...330R 330R WHITE BROWN RED RS 485 Interface i Connect the reader shield to a suitable earth point DO NOT connect the shield to a ground or AUX connection Warning When connecting the Reader in RS 485 Mo...

Page 16: ...485 USB Converter 2 Power up the card reader and RS 485 USB Converter 3 Open Hyper Terminal or a similar serial terminal program set the communications port to the RS 485 USB Converter and set the par...

Page 17: ...e to indicate data entry mode has been entered and that you can present the card the required number of times to set the desired option Address Programming Options 1 Card Reading Format 2 Data Output...

Page 18: ...C key and the available modes will toggle on the screen Setting Description CSN Card serial number CSN or electronic serial number ESN reading converts the serial number of the card to a site code an...

Page 19: ...ll typically occur however it is recommended to use industry standard 34 Bit 32 Bit Wiegand has no parity or other error checking 34 Bit Wiegand 2 Standard 34 Bit Wiegand data sent on the D0 and D1 da...

Page 20: ...ault Sector press the G key from the main menu 7 10 Encryption Keys Applies to RS 485 programming mode only You are able to program custom keys in to the Reader by selecting the encryption option prog...

Page 21: ...d with data in sector 3 The data has a start marker 0xAABBCCDDEEFF at the start of the sector 3 packed decimal BCD encoded site values and ends with 5 unpacked decimal BCD card values It is then fille...

Page 22: ...the reader press the O key from the main menu 7 14 Output Mode Applies to RS 485 programming mode only The Output Mode defines the output format of the reader Three formats are available Wiegand ICT S...

Page 23: ...nfigured Wiegand format The b specifier outputs in hexadecimal format In all other cases uppercase means hexadecimal format and lowercase means decimal format The definitions of each specifier is list...

Page 24: ...he essential details needed to help ensure the correct installation of the tSec Reader tSec Mini tSec Standard tSec Extra 115mm 4 53 tSec Standard tSec Extra 84mm 3 31 tSec Mini 45mm 1 77 tSec Standar...

Page 25: ...3 125kHz 25mm 0 98 Wiegand Interface Multiple format 26 or 34 Bit data 0 and data 1 card defined Max Cable Distance 150m 492ft Frequency 13 56 MHz ISO IEC 14443 Type A 125KHz pulse width modulated Mul...

Page 26: ...ard Reader Installation Manual June 2017 10 New Zealand and Australia Intentional Transmitter Product Statement The R NZ compliance label indicates that the supplier of the device asserts that it comp...

Page 27: ...se of an equivalent new product Disposing of this product correctly will help save valuable resources and prevent any potential negative effects on human health and the environment which could otherwi...

Page 28: ...ssembly portal locking device s must be evaluated to ULC S533 and CAN ULC S104 Must be installed with CAN ULC S319 Listed portal locking device s for ULC installations Input power must be supplied by...

Page 29: ...n which can be deter mined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Re orient the receiving antenna Increa...

Page 30: ...Technology Card Reader Installation Manual June 2017 14 Industry Canada Statement This class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la n...

Page 31: ...XVRC tSec Extra Vandal Resistant Protective Cover Standard Range PRX TSEC STD tSec Standard Card Reader PRX TSEC STD KP tSec Standard Card Reader with Keypad PRX TSEC STD KP VRC tSec Standard Card Rea...

Page 32: ...the products and because the products may be used in conjunction with products not manufactured by ICT ICT cannot guarantee the performance of the security system ICT s obligation and liability under...

Page 33: ...below Integrated Control Technology P O Box 302 340 North Harbour Post Centre Auckland New Zealand 4 John Glenn Ave Rosedale North Shore City 0632 Auckland New Zealand Phone 64 9 476 7124 Toll Free Nu...

Page 34: ...4 Designers manufacturers of integrated electronic access control security and automation products Designed manufactured by Integrated Control Technology Ltd Copyright Integrated Control Technology Li...

Reviews: