5. Setting up the device
16
Menu level
Parameterisation level
Setting the initial value of the analog output,
Default:
The initial value is adjusted from the smallest to the highest digit with
[▲] [▼]
and confirmed
digit per digit with
[P]
. A minus sign can only be parameterized on the leftmost digit. After the
last digit the device changes back into menu level.
Overflow behaviour,
Default:
To recognise and evaluate faulty signals, e.g. by a controller, the overflow behaviour of the
analog output can be defined. As overflow can be seen either
, that means the analog
output runs on the set limits e.g. 4 and 20 mA, or
(input value smaller than initial value,
analog output switches on e.g. 4 mA),
(higher than final value, analog output switches on
e.g. 20 mA). If
or
is set, the analog output switches on the least significant or
leftmost possible binary value. This means that values of e.g. 0 mA, 0 VDC or values higher
than 20 mA or 10 VDC can be reached. With
[P]
the selection is confirmed and the device
changes into menu level.
Back to menu group level,
:
With
[P]
the selection is confirmed and the device changes into menu group level
.