9. Specifications
Specifications
Model A48
Nominal size
63, 80, 100, 160
Scale range
-30 ... +50 °C to 0 ... 120 °C
Working range
Full scale value
Case
Aluminium
Process connection
Flange, Ø d
2
= 61 mm, steel galvanised, adjustable
on stem
Stem
Copper alloy
Indication accuracy
Class 2 per EN 13190
Indication correction
At bottom of stem
Scale angle
aprox. 270°
Specifications
Model A50
Nominal size
63, 80, 100, 160
Scale range
-30 ... +50 °C to 0 ... 200 °C
Working range
Full scale value
Case
■
Model A50.10
■
Model A50.20
Aluminium
Steel, galvanised
Process connection
Thermowell G ½ B, copper alloy
Thermowell
Copper alloy, removable with retainer screw
Permissible operating pressure at
thermowell
Max. 6 bar
Indication accuracy
Class 2 per EN 13190
Indication correction
At bottom of stem
Scale angle
aprox. 270°