![ICS Schneider Messtechnik A43 Operating Instructions Manual Download Page 18](http://html1.mh-extra.com/html/ics-schneider-messtechnik/a43/a43_operating-instructions-manual_3529682018.webp)
18
EN
When returning the instrument, use the original packaging or a suitable transport
packaging.
To avoid damage:
1. Place the instrument, along with shock-absorbent material, in the packaging.
Place shock-absorbent material evenly on all sides of the transport packaging.
2. If possible, place a bag containing a desiccant inside the packaging.
3. Label the shipment as carriage of a highly sensitive measuring instrument.
Information on returns can be found under the heading “Service” on our local
website.
8.3 Disposal
Incorrect disposal can put the environment at risk.
Dispose of instrument components and packaging materials in an environmentally
compatible way and in accordance with the country-specific waste disposal regulations.
9. Specifications
Specifications
Model A43
Nominal size
63, 80, 100
Scale range
-30 ... +50 °C to 0 ... 120 °C
Working range
Full scale value
Case
■
Model A43.10
■
Model A43.20
■
Model A43.30
Aluminium
Steel, galvanised
Plastic, black
Process connection
Thermowell G ½ B, brass
Stem
Aluminium
Thermowell
Brass
Permissible operating pressure at
thermowell
Max. 6 bar
Indication accuracy
Class 2 per EN 13190
Indication correction
At bottom of stem
Scale angle
aprox. 270°
8. Dismounting, return and disposal / 9. Specifications