11
TABLE 2
Air Flow (CFM) – SUPREME with 1/3 HP motor
0,1
0,2
0,3
0,4
0,5
0,6
0,7
LOW
715
700
690
675
660
650
635
MED-LOW
935
900
870
835
800
770
735
MED-HIGH
1090
1050
1010
970
930
890
850
HIGH
1285
1250
1220
1185
1150
1120
1085
Blower Speed
Static Pressure
The airflow values are expressed in cubic feet per minute (CFM’), rounded to 5 CFM more or less.
These readings were taken with the air filter installed.
TABLE 3
Air Flow (CFM) – SUPREME with 1 HP motor
0,1
0,2
0,3
0,4
0,5
0,6
0,7
LOW
1035
1030
1030
1025
1020
1020
1015
MED-LOW
1315
1300
1285
1270
1255
1240
1225
MED-HIGH
1715
1650
1590
1525
1460
1400
1335
HIGH
1935
1900
1870
1835
1800
1770
1735
Blower Speed
Static Pressure
The airflow values are expressed in cubic feet per minute (CFM), rounded to 5 CFM more or less.
These readings were taken with the air filter installed.
FIGURE 5
Dimensions
DNS-0982 Rev.B
Summary of Contents for SUPREME FEM10-M2401AM-A
Page 12: ...12 FIGURE 6 Wiring Diagram 10 kW with 1 3 HP motor...
Page 13: ...13 FIGURE 7 Wiring Diagram 15 kW with 1 3 HP motor...
Page 14: ...14 FIGURE 8 Wiring Diagram 18 and 20 kW with 1 3 HP motor and 20 kW with 1 0 HP...
Page 15: ...15 FIGURE 9 Wiring Diagram 23 kW with 1 3 HP and 1 HP motor...
Page 16: ...16 FIGURE 10 Wiring Diagram 27 kW with 1 HP motor...
Page 17: ...COMPONENTS AND REMPLACEMENT PARTS 17...
Page 18: ...18 PARTS LIST Exploded View B50002F Please refer to Table 4 p 20...