PM
-
3133i User
’s Manual v1.02
Last Revised: Apr. 2023 Page: 75
Copyright © ICP DAS Co., Ltd. All Rights Reserved.
E-mail: [email protected]
Q15. The Power Meter can be connected to a remote display (via RS-485).
A:
Power Meter can be connected to VPD-13x or VPD-14x series via RS-485:
B:
Two Masters Share One Slave (via tSH-735):
This function allows two master devices connected to different serial ports to share
slave devices. Modbus mode can be used to convert the Modbus RTU/ASCII
protocols, while raw data mode can be used for DCON or other query-response
protocols. Different baud rates and data formats can also be used on the different
serial ports. The built-in cache function reduces the loading of serial communication
on the slave port by removing duplicated queries when the two master devices are
requesting the same information.